Resetting, reseating, or replacing a
LIM will cause both links on the card to fail. If the card is a LIM, place the
links on the LIM out of service by entering the dact-slk command.
Wait five minutes to see if the card corrects
itself.
Enter the following command to check the database
level on the card:
rept-stat-db:display=all
If the problem persists, enter the following command
to retrieve the terminal types and port numbers:
rtrv-trm
If the card is a LIM, enter the following command to
deactivate the slk:
dact-slk:loc=xxxx:port=y
where xxxx is the card location, and y is the port
on the card specified in the location parameter.
Enter the following command to inhibit each OAP
terminal displayed in the output from
3:
inh-trm:trm=x
where x is the port number.
Note:
The force parameter is required for the last OAP
terminal inhibited.
Enter the following command to change the state of
the card to OOS-MT-DSBLD
init-card:loc=xxxx
where xxxx is the card location stenciled on the
shelf of the system.
Enter the following command to change the state of
the card to IS-NR:
alw-card:loc=xxxx
where xxxx is the card location stenciled on the
shelf of the system.
If the card is a LIM, enter the following command to
activate the slk:
act-slk:loc=xxxx:port=y
where xxxx is the card location, and y is the port
on the card specified in the location parameter.
After the card has been reloaded (a message appears
to confirm completion of the load), enter the following command to verify the
database is consistent (same level as the other cards in the system).
rept-stat-card
Check the consistency of the card by entering the
following command:
rept-stat-db:display=except
Enter the following command to return the OAP
terminals to the in-service state: