Oracle® Communications EAGLE Unsolicited Alarm and Information Messages Reference Release 46.8 F11887 Revision 1 |
|
![]() Previous |
![]() Next |
The T7 timer has timed out. Either there is too much incoming traffic on M2PA signaling links, or the far end node is taking too long to acknowledge the messages sent to it by the signaling terminal.
RLGHNCXA21W 00-12-07 12:01:43 EST EAGLE 35.0.0 ** 0014.0217 ** SLK 1205,A nc00027 REPT-LKF: XDA-excess acknowledge delay SLC=03 FECLLI=testclli CLASS=MTP2
Note:
The Class parameter in the example is optional.Alarm Level: Major
Recovery
rept-stat-card:mode=full:loc=xxxx
to determine if the signaling link is M2PA. If so, continue to 2. If not, skip to 3.rept-stat-iptps
and msucount –l
commands to determine how much traffic is received and transmitted on the M2PA links.rtrv-ls
command to determine the amount of rsvdslktps and maxslktps traffic that the M2PA signaling link can receive based on what is provisioned. (The rsvdslktps
is the reserved-per-signaling-link TPS for IPSG linkset; this indicates the minimum guaranteed capacity for each link in the linkset. The maxslktps
is the maximum-per-signaling-link TPS; this indicates the maximum traffic permitted when sufficient unused capacity is present on the host card.)chg-ls
command to increase or decrease the minimum and maximum TPS for the M2PA signaling link.