0571 - Sentinel Socket is Inactive

The EAGLE 5 ISS - Sentinel socket connection is inactive. Any of the following conditions may be a cause.
  • Turned off scopy bit through chg-eiscopy command if it is already on
  • Lost connection with Sentinel/IMF server
  • Link being monitored is deleted
  • Adaptor type is changed to non-M2PA on the IPLIM card connected to IMF/sentinel server using chg-assoc/chg-appl-sock
  • Internal problem occured at the LIM card hosting the corresponding link
Example
RLGHNCXA21W 00-12-07 12:01:43 EST  EAGLE 38.0.0
*   0100.0571 *  SLK 1201,A   lsn123     Sentinel Socket is inactive

Alarm Level: Minor

Recovery

  1. Check the physical connectivity to the Sentinel/IMF server and application status running at the Sentinel/IMF servers.
    Correct any physical connection discrepancy found.
  2. If the physical connectivity is good, then there may be an internal problem at the LIM card hosting the corresponding link. Contact My Oracle Support (MOS).