0196 - 1114-PHS, 1114-SHS, 1116-PHS clks Failed

This message indicates the following clocks failed:

  • The primary High Speed clock for the TDM card in slot 1114

  • The secondary High Speed clock for the TDM card in slot 1114

  • The primary High Speed clock for the TDM card in slot 1116

Example
station1234 99-03-05 16:28:08 EST  EAGLE 31.6.0 
** 0052.0196  ** HS CLOCK SYSTEM 1114-PHS, 1114-SHS,1116-PHS clks failed

Alarm Level: Major

Recovery

  1. Use the rept-stat-clk command to determine the current clock configuration.
    Example of the output:
    rept-stat-clk
        Command entered at terminal #3.
    ;
        tekelecstp 99-03-05 13:34:15 EST EAGLE 31.6.0
        CARD LOC= 1114 (Active   )       CARD LOC= 1116 (Isolated )
        PRIMARY BITS      = Active        PRIMARY BITS      = -----
        SECONDARY BITS    = Idle          SECONDARY BITS    = -----
        HS PRIMARY CLK    = Active        HS PRIMARY CLK    = -----
        HS SECONDARY CLK  = Idle          HS SECONDARY CLK  = -----
        HS CLK TYPE       = E1 UNFRAMED   HS CLK TYPE       = -----
        HS CLK LINELEN    = SHORTHAUL     HS CLK LINELEN    = -----
                                         PST           SST       AST
        SYSTEM CLOCK                     IS-NR         ACTIVE    ALMINH 
        ALARM STATUS     = No Alarms. 
        # Cards using CLK A = 009        # Cards with bad CLK A = 000
        # Cards using CLK B = 000        # Cards with bad CLK B = 009
        # Cards using CLK I = 000
                                         PST           SST       AST
        HS SYSTEM CLOCK                  IS-NR         ACTIVE    ALMINH 
        ALARM STATUS     = No Alarms. 
        # Cards using HSCLK A = 001      # Cards with bad HSCLK A = 000
        # Cards using HSCLK B = 000      # Cards with bad HSCLK B = 002
        # Cards using HSCLK I = 000
        Command Completed.
  2. Follow local procedures to troubleshoot and repair the primary E1/T1 High Speed clock.
  3. If one of the reference clocks is still not functioning, reseat the associated TDM card.
  4. If one of the reference clocks is still not functioning, replace the associated TDM card.