Diameter Application is unable to process any
messages because it is Unavailable. A Diameter Application can become
unavailable when:
The Admin State is set to Disable with the
forced shutdown option.
The Admin State is set to Disable with the
graceful shutdown option and the graceful shutdown timer expires.
It reaches Congestion Level 3.
Severity:
Critical
Instance:
N/A
HA Score:
Normal
Auto Clear Seconds:
0
OID:
DiameterApplicationUnavailable
Recovery:
Display and monitor the Diameter Application status
by selecting
Diameter > Maintenance > Applications in the SO GUI. Verify that
the Admin State variable is set as expected.
A Diameter Application operation status becomes
Unavailable when either the Admin State is set to Disable with the Forced
Shutdown option, or the Admin State is set to Disable with the Graceful
Shutdown option and the Graceful Shutdown timer expires.
A Diameter Application can also become Unavailable
when it reaches Congestion Level 3, if enabled.
Note:
This alarm will not be raised when the Diameter application is
shutting down gracefully or application is in Disabled state. Only the Diameter
Application operational status will be changed to Unavailable.
Check the Event History logs for additional DIAM
events or alarms for this MP server.