6 RSA MEALs

RSA MEALs defines various Measurements, SysMetric, and Alarms used for reporting the application behavior. All these RSA MEALs are defined using DCA Custom MEAL Framework.

Configure RSA MEALs

RSA MEALs are pre-populated if RSA is configured using RSA JSON file. See Configuring RSA Business Logic and Database Schema for more details.

Alternatively, RSA MEALs can be configured manually using the following steps. See DCA Programmer’s Guide for detailed information.
  1. From the NO GUI main menu, DCA Framework, and then Diameter Security Application, and then Custom MEALs.
  2. Click Insert
  3. Fill in the fields to define the MEAL.
  4. Repeat steps 2 to 4 for each MEAL.

Measurements

The following tables lists the total Rx interface messages, total Rx Interface messages (AAR/RAR/STR/ASR) processed and sent by the Rx- ShUDR application.

Table 6-1 Rx-ShUDR Measurements

Measurement Tag Measurement Purpose Measurement Details
TotalRxIntMsgProcessed Total number of Rx Interface messages (AAR-I/U, RAR, STR and ASR) processed successfully and forwarded to PCRF. Table 6-2
TotalRxIntMsgRejected Total number of Rx Interface messages (AAR-I/U, RAR, STR and ASR) rejected with error answer due to failure occur in the business logic execution. Table 6-3
TotalShUDRMsgCreated Total number of Sh:UDR diameter messages created and sent by RSA application to HSS successfully. Table 6-4
ShUDRCreateAndSendFailCnt Total number of Sh:UDR diameter messages creation/Send failed due to runtime failures occured in business logic execution. Table 6-7
TotalShUDRAnsSuccess Total number of Sh:UDR answer messages received successfully. Table 6-5
TotalShUDRAnsFailed Total number of Sh:UDR error answer messages received at Rx ShUDR application. Table 6-6

Table 6-2 totalRxInterfaceMsgProcessed Custom Meal

Measurement Tag TotalRxInterfaceMsgProcessed
Template Type Counter
Measurement type Scalar

Table 6-3 totalRxInterfaceMsgRejected Custom Meal

Measurement Tag TotalRxInterfaceMsgRejected
Template Type Counter
Measurement type Scalar

Table 6-4 TotalShUDRMsgCreated Custom Meal

Measurement Tag TotalShUDRMsgCreated
Template Type Counter
Measurement type Scalar

Table 6-5 TotalShUDRAnsSuccess Custom Meal

Measurement Tag TotalShUDRAnsSuccess
Template Type Counter
Measurement type Scalar

Table 6-6 TotalShUDRAnsFailed Custom Meal

Measurement Tag TotalShUDRAnsFailed
Template Type Counter
Measurement type Scalar

Table 6-7 ShUDRCreateAndSendFailCnt Custom Meal

Measurement Tag ShUDRCreateAndSendFailCnt
Template Type Counter
Measurement type Scalar

Alarms

This Alarm will be raised if any failure occurs in Application business logic execution which may result in traffic loss.

Table 6-8 Alarms

Alarm Name RxShUDRAppExecFailed
Template Type Event
Alarm Description Failed executing Rx-ShUDR application business logic. Disable the Application until the problem is resolved.
Alarm Autoclear Interval 90
Alarm Throttling Interval 60