Diameter Connection Alarm Groups configuration elements
Table 2-20 describes the fields on the Connection Alarm Groups View, Insert, and Edit pages. Data Input Notes apply only to the Insert and Edit pages; the View page is read-only.
Table 2-20 Connection Alarm Groups Configuration Elements
Field (* indicates required field) | Description | Data Input Notes |
---|---|---|
*Connection Alarm Group Name |
Unique name of the Connection Alarm Group. This is a group of Connections used by the Alarm Group feature if it is enabled on the tab. |
Format: string, case-sensitive; alphanumeric and underscore (_); cannot start with a digit and must contain at least one alpha Range: 1 - 32 characters Default: none |
*Connection Name |
A list of Connections. [Insert] and [Edit] - The field contains an Add button that can be clicked to create text boxes for Connection names. Each entry is numbered to indicate the number of Connection names that have been added. |
Format: List that includes the names of all Connections that have not been included in a different Connection Alarm Group yet Range: configured Connection names The list of Connection Names are hyperlinks. Click on a hyperlink to view more detail on the selected Connection. Note: If the maximum number (200) of Connections has already been created, then an error displays. |
*Throttle Minor Threshold (%) |
This percentage value indicates the number of connections failed out of total number of connections configured for that Connection Alarm Group. When the count of failed connections reaches the minor throttle level, minor threshold alarm is raised. The following constraints apply to the value:
|
Format: numeric Range: 2 - 96 Default: 25 |
*Abatement Minor Threshold (%) |
This percentage value indicates the number of connections failed out of total number of connections configured for that Connection Alarm Group. When the count of failed connections falls under the minor abatement level, minor threshold alarm is cleared. The following constraints apply to the value:
|
Format: numeric Range: 1 - 95 Default: 20 |
*Throttle Major Threshold (%) |
This percentage value indicates the number of connections failed out of total number of connections configured for that Connection Alarm Group. When the count of failed connections reaches the major throttle level, major threshold alarm is raised. The following constraints apply to the value:
|
Format: numeric Range: 4 - 98 Default: 50 |
*Abatement Major Threshold (%) |
This percentage value indicates the number of connections failed out of total number of connections configured for that Connection Alarm Group. When the count of failed connections falls under the major abatement level, major threshold alarm is cleared. The following constraints apply to the value:
|
Format: numeric Range: 3 - 97 Default: 45 |
*Throttle Critical Threshold (%) |
This percentage value indicates the number of connections failed out of total number of connections configured for that Connection Alarm Group. When the count of failed connections reaches the critical throttle level, critical threshold alarm is raised. The following constraints apply to the value:
|
Format: numeric Range: 6 - 100 Default: 75 |
*Abatement Critical Threshold (%) |
This percentage value indicates the number of connections failed out of total number of connections configured for that Connection Alarm Group. When the count of failed connections falls under the critical abatement level, critical threshold alarm is cleared. The following constraints apply to the value:
|
Format: numeric Range: 5 - 99 Default: 70 |