A.5 Error Code 510
- Associated Error Category
- Binding Found But Unable To Route
- Description
- A slave session could not be routed because, on polling the slave, sessionRef was no longer in the binding database.
- Associated P-DRA Alarm/Event
- N/A
- Associated Measurement
- SbrSlavePollingFail
- Associated Diameter Interface / Message Type
-
- Gx/Gxx CCR-I
- Rx AAR
- Gx-Prime CCR-I
- GUI Configurable
- Yes
Recovery
- See Early binding Processing with PCRF Pool in the Error Resolution appendix of the Policy and Charging Application User Guide to investigate and understand
- Go to the PCA SOAM GUI at to check binding SBRs' status.
- Go to the to check binding SBR's congestion alarm/event info to determine a relation with the error.
- Go to the PCA SOAM GUI to search for relevant measurements. Select, but not limited to, "SBR Binding Exception" Measurement Group for the measurements directly related to this error.