A.6 Error Code 511
- Associated Error Category
- Binding Found But Unable To Route
- Description
- A slave session could not be routed because, on polling the master, sessionRef was no longer in the binding database.
- Associated P-DRA Alarm/Event
- N/A
- Associated Measurement
- SbrSlavePollingFail
- Associated Diameter Interface / Message Type
-
- Gx/Gxx CCR-I
- Rx AAR
- Gx-Prime CCR-I
- GUI Configurable
- Yes
Recovery
- See Early binding Processing with PCRF Pool in the Error Resolution appendix of the Policy and Charging Application User Guide to investigate and understand the circumstances where the error occurs.
- Go to the PCA SOAM GUI at to check binding SBRs' status.
- Get the measurement report from to the frequency of the relevant measurements. Select, but not limited to, "SBR Binding Exception" Measurement Group to determine the frequency of the relevant measurements.