A.8 Error Code 513

Associated Error Category
Binding Found But Unable To Route
Description
A slave session could not be routed because, on polling the master, an internal error occurred.
Associated P-DRA Alarm/Event
N/A
Associated Measurement
SbrSlavePollingFail
Associated Diameter Interface / Message Type
  • Gx/Gxx CCR-I
  • Rx AAR
  • Gx-Prime CCR-I
GUI Configurable
Yes

Recovery

  1. Go to the PCA SOAM GUI at Main Menu, and then Status & Manage, and then Server to obtain the Policy DRA DA-MP and binding SBR status.
  2. Go to the Main Menu, and then Alarms & Events, and then View History to obtain the congestion alarm/event for Policy DRA DA-MP and/or binding SBR, if congestion occurs. Some congestion conditions may be released after a short while. The error may not persist after the congestion condition is gone.
  3. Go to Policy DRA SOAM GUI at Main Menu, and then Communication Agent, and then Maintenance, and then Connection Status to check the server connection status. The error may be caused by a disconnection between the local and peer nodes that the message was retransmitted the maximum number of times without receiving a response.
  4. Get the measurement report from Main Menu, and then Measurements, and then Report for, but not limited to, "ComAgent Exception," "Connection Congestion," "SBR Binding Exception" and "Policy DRA Congestion" Measurement Groups.