A.8 Error Code 513
- Associated Error Category
- Binding Found But Unable To Route
- Description
- A slave session could not be routed because, on polling the master, an internal error occurred.
- Associated P-DRA Alarm/Event
- N/A
- Associated Measurement
- SbrSlavePollingFail
- Associated Diameter Interface / Message Type
-
- Gx/Gxx CCR-I
- Rx AAR
- Gx-Prime CCR-I
- GUI Configurable
- Yes
Recovery
- Go to the PCA SOAM GUI at Policy DRA DA-MP and binding SBR status. to obtain the
- Go to the Policy DRA DA-MP and/or binding SBR, if congestion occurs. Some congestion conditions may be released after a short while. The error may not persist after the congestion condition is gone. to obtain the congestion alarm/event for
- Go to Policy DRA SOAM GUI at to check the server connection status. The error may be caused by a disconnection between the local and peer nodes that the message was retransmitted the maximum number of times without receiving a response.
- Get the measurement report from Policy DRA Congestion" Measurement Groups. for, but not limited to, "ComAgent Exception," "Connection Congestion," "SBR Binding Exception" and "