3.38.5 RxFabrNgnPsDrop
- Measurement ID
 - 10672
 - Measurement Group
 - Full Address Resolution Exception
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Single
 - Description
 - The number of FABR ingress NGN-PS messages discarded or rejected.
 - Collection Interval
 - 5 min
 - Peg Condition
 - Each time NGN-PS Diameter message is dropped due these conditions:
                        
- In scenarios where the configured action is 'Discard'
                              
- where address resolution is unsuccessful
 - Event sending to ComAgent is unsuccessful
 - Delivery failure notification from
 
 - Event sending failure to DRL.
 
 - In scenarios where the configured action is 'Discard'
                              
 - Measurement Scope
 - Server Group
 
Recovery
- When non-zero, examine other failure measurements (RxFabrUnkApplId, RxFabrDecodeFailureResol, RxFabrResolFailAll, RxFabrResolFailCmdcode, RxFabrResolFailNoAddrAvps, TxFabrDbConFail, TxFabrAbandonRequest, RxFabrInvalidImsiMcc, RxFabrBlacklistedImsi, RxFabrBlacklistedMsisdn) to isolate reasons for failures.
 - It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance.