3.38.5 RxFabrNgnPsDrop

Measurement ID
10672
Measurement Group
Full Address Resolution Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of FABR ingress NGN-PS messages discarded or rejected.
Collection Interval
5 min
Peg Condition
Each time NGN-PS Diameter message is dropped due these conditions:
  • In scenarios where the configured action is 'Discard'
    • where address resolution is unsuccessful
    • Event sending to ComAgent is unsuccessful
    • Delivery failure notification from
  • Event sending failure to DRL.
Measurement Scope
Server Group

Recovery

  1. When non-zero, examine other failure measurements (RxFabrUnkApplId, RxFabrDecodeFailureResol, RxFabrResolFailAll, RxFabrResolFailCmdcode, RxFabrResolFailNoAddrAvps, TxFabrDbConFail, TxFabrAbandonRequest, RxFabrInvalidImsiMcc, RxFabrBlacklistedImsi, RxFabrBlacklistedMsisdn) to isolate reasons for failures.
  2. It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance.