3.55.3 RxGyRoAnsNon2xxxFromPeerPerCmd
- Measurement ID
- 11396
- Measurement Group
- OC-DRA Diameter Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed (by Diameter Request Command Abbreviation i.e. CCR-I/U/T/E, RAR and “Total”)
- Description
- The number of Gy/Ro Diameter Credit Control Application Request messages successfully relayed by OC-DRA that received an Answer from the peer with a non-2xxx (Non-successful) Result-Code value.
- Collection Interval
- 5 min
- Peg Condition
- Each time OC-DRA receives an Answer from the peer with a non-successful Result-Code AVP (one containing a value that is not in the range of 2000 – 2999).
Note:
This measurement is pegged twice, once for the Diameter message command abbreviation and once for "Total". - Measurement Scope
- All
Recovery
- No action required.