5.1.40 MTP2 Config

A Mtp2 Config is an entity to configure all the mtp2 timers.

Select the VSTP, and then Configuration, and then MTP2 Config page. The page displays the fields on the MTP2 Config View, Insert, and Edit pages.

Note:

Data Input Notes apply to the Insert and Edit pages only; the View page is read-only.

Table 5-40 MTP2 Config Fields

Field Description Data Input Notes
Name Name for this Mtp2 Config, which must be unique within the VSTP site.

This is a mandatory field.

Valid names are strings between one and 32 characters, inclusive. Valid characters are alphanumeric and underscore. The name must contain at least one alpha and must not start with a digit.
T1 Timer Alignment or Ready timer. Range = Minimum: 5000, Maximum: 350000 (milliseconds)
Values:
  • ANSI timer sets 5000 – 20000
  • ITU timer sets 40000 – 50000
  • E1 HSL timer sets 25000 – 350000
  • T1 HSL timer sets 16000 – 151000
T2 Timer Not Aligned timer. Range = Minimum: 5000, Maximum: 480000 (milliseconds)
Values:
  • ANSI timer sets 5000 – 30000
  • ITU timer sets 5000 – 150000
  • E1 HSL timer sets 5000 – 150000
  • T1 HSL timer sets 5000 – 14000
T3 Timer Aligned timer. Range = Minimum: 1000, Maximum: 20000 (milliseconds)
Values:
  • ANSI timer sets 5000 – 20000
  • ITU timer sets 1000 – 2000
  • E1 HSL timer sets 1000 – 2000
  • T1 HSL timer sets 5000 – 14000
T4 Emergency Timer Proving period Emergency timer. Range = Minimum: 200, Maximum: 10000 (milliseconds)
Values:
  • ANSI timer sets 200 – 1000
  • ITU timer sets 400 – 600
  • E1 HSL timer sets 400 – 600
  • T1 HSL timer sets 3000 – 10000
T4 Normal Timer Proving period normal timer. Range = Minimum: 500, Maximum: 70000 (milliseconds)
Values:
  • ANSI timer sets 500 – 5000
  • ITU timer sets 7500 – 9500
  • E1 HSL timer sets 3000 – 70000
  • T1 HSL timer sets 3000 – 30000
T5 Timer Sending SIB timer. Range = Minimum: 40, maximum: 500 (milliseconds)
Values:
  • ANSI timer sets 40 – 500
  • ITU timer sets 80 – 120
  • E1 HSL timer sets 80 – 120
  • T1 HSL timer sets 80 – 120
T6 Timer Remote congestion timer. Range = Minimum: 1000, Maximum: 10000 (milliseconds)
Values:
  • ANSI timer sets 1000 - 10000
  • ITU timer sets 3000 - 6000
  • Q.703 timer sets 3000 - 6000
  • T1 HSL sets 3000 - 6000
T7 Timer Excessive delay of acknowledgment timer. Range = Minimum: 200, maximum: 3000 (milliseconds)
Values:
  • ANSI timer sets 200 – 3000
  • ITU timer sets 500 – 2000
  • E1 HSL timer sets 500 – 2000
  • T1 HSL timer sets 500 – 2000

You can perform add, edit, or delete tasks on VSTPConfigurationMTP2 Config page.

Adding a MTP2 Config

Perform the following steps to configure a new MTP2 Config:

  1. Click Insert.

    Note:

    The new MTP2 Config must have a name that is unique across all MTP2 Config at the SOAM. In addition, the MTP2 Config's IP Port combination must also be unique across all MTP2 Config configured at the SOAM.
  2. Enter the applicable values.
  3. Click OK, Apply, or Cancel

Editing a MTP2 Config

Use this procedure to change the field values for a selected MTP2 Config. (The MTP2 Config Name field cannot be changed.):
  1. Select the MTP2 Config row to be edited.
  2. Click Edit
  3. Enter the updated values.
  4. Click OK, Apply, or Cancel

Deleting a MTP2 Config

Use the following procedure to delete a MTP2 Config.

Note:

You cannot delete a MTP2 Config if it is part of the configuration of one or more Linksets.
  1. Select the MTP2 Config to be deleted.
  2. Click Delete.
  3. Click OK or Cancel.