3.19.146 70375 - Linkset Alarm Aggregation Threshold Reached

Alarm Group:
vSTP
Description:
This alarm is generated when the number of Linkset failure alarms for the network element is equal to or greater than the configured Critical aggregation threshold. Individual Linkset failure alarms are cleared and one Critical aggregate alarm is raised. To review or change aggregation thresholds, go to VSTP > Configuration > Alarm Aggregator Options, and modify Linkset Critical Agg Alarm Threshold.
Severity:
Critical
Instance:
<Network Element>
Clear behavior:
When the failed Linkset count falls to or below 80% of the configured Critical threshold. With the default threshold of 300, the default abatement level is 240.
Throttle Seconds:
10
OID:
vSTPLinksetAlarmAggregationThresholdReachedNotify
Recovery:
It is recommended to contact My Oracle Support if further assistance is needed.