25510 - Multiple DA-MP Leader Detected Alarm
- Alarm Group:
- DIAM
- Description:
- This alarm occurs when multiple active DA-MP leaders have been detected.
- Severity:
- Critical
- Instance:
- <NetworkElement>
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- eagleXgDiameterMultipleDaMpLeadersDetectedNotify
- Cause:
- The alarm #25510 raises:
- When more than one DA-MP report themselves as Leader.
- When DSR process is running on all DA-MPs and ComAgent Connection is down between two or more DA-MP's.
- Diagnostic Information:
-
- This alarm is raised against the Network Element when multiple DA-MPs report themselves as Leader.
- Examine the alarm log from Main Menu > Alarms & Events on Active SOAM Server.
- When this alarm is raised Existing IPFE Connection, Route List, and Peer Node alarms will be cleared.
- New IPFE Connection, Route List, and Peer Node alarms are suppressed.
Recovery: