Defining Control Charts

To define control charts, use the Control Charts component (QS_CL_CHART). This topic discusses how to define control charts.

Pages Used to Define Control Charts

Page Name Definition Name Usage

Defining Control Chart Page

QS_CL_CHART0

Define the scope of the chart, such as chart prototype and testing zones. Use these charts for real-time or offline data analysis.

Copy Configuration Item Page

QS_COPY0_PNL

Creates a new chart by copying an existing chart.

Defining Control Chart Page

Use the Define Control Chart page (QS_CL_CHART0) to define the scope of the chart, such as chart prototype and testing zones.

Use these charts for real-time or offline data analysis.

Navigation:

Quality, and then Define Methods and Procedures, and then Control Charts, and then Define Control Chart

Field or Control Description

Copy From icon

Click the Copy From button to create the new control chart by copying from an existing control chart. When you click this button, the Copy Configuration Item page appears.

Chart Prototype

Select a chart prototype. Values are: X & Moving Range, Xbar & Range, Xbar & Sigma, c Chart, np Chart, p Chart, and u Chart.

The chart prototype that you select defines the standard formulas that are used to calculate subgroup values and control limits.

Test Zones

Enter the number of divisions between the upper control limit (UCL) and the mean (CL) limit lines that are used for control-test evaluations. Zones typically represent standard deviations.

Data Type

Select the type of data that is to be plotted on this chart. Values include:

Variables: Measurable characteristics, such as length, mass, or time, and for characteristics that are derived from measurable characteristics, such as volume, density, or area.

Defects: Characteristics that represent defect counts, which are counts of the number of defects observed per unit, such as scratches, blemished, or missing subcomponents.

Defectives: Characteristics that represent counts of defective units and counts of how many units are defective using a pass or fail criteria.

Copy Configuration Item Page

Use the Copy Configuration Item page (QS_COPY0_PNL) to creates a new chart by copying an existing chart.

Navigation:

Click the Copy From button on multiple pages in Quality.

Create a new control chart by selecting an existing chart from the Copy From field.