WFM_TDR_VALIDATE_REST_PERIOD_DURATION_AP Fast Formula

This fast formula is associated with the delivered rule template Compare Rest Between Time Events Template. It compares the end and start times of consecutive reported time entries identified by the time category of the rest period.

If the interim time is less than the defined rest period, the corresponding defined message appears. If no message is defined, the default message appears. The message severity is an output value associated with the displayed message. This template uses an array processing formula.

Parameters

Name Data Type Description
WORKED_TIME_CONDITION Time category Time category that identifies the time entries to use to determine whether the minimum rest period was met for the two shifts.
REST_PERIOD_IN_MINUTES Fixed number Minimum nonworked time, in minutes, required between consecutive end and start time entries.
OVERRIDE_MESSAGE_CODE Message Message that appears when the time between the end of one shift and start of the next shift is less than the defined rest period.

Outputs

Name Message Severity
OUT_MSG Specify whether the output message is informational, warning, or error

Example

Scenario: The rule parameter REST_PERIOD_IN_MINUTES has the value 480 minutes.

Day Payroll Time Type Mon Output
Mon Regular 11a to 10p None
Tue Regular 4a to 10a The message appears because the rest period is less than 480 minutes (8 hours).