Private Cloud Appliance X11 Management Switch Ethernet Connections

This section applies to the Private Cloud Appliance X11 rack configuration, which uses Oracle Server X11 2U compute nodes. The table lists the cabling connections for the management switch. These are Ethernet connections intended for the internal administration network.

From Rack Unit From Component and Port To Management Switch Rack Unit and Port

N/A

bastion/gateway

U23: port 2

U40-41 (^)

N/A

N/A

U38-39 (*)

N/A

N/A

U36-37 (*)

compute node: NET MGMT

compute node: NET0

U23: port 34

U23: port 33

U34-35 (*)

compute node: NET MGMT

compute node: NET0

U23: port 32

U23: port 31

U32-33 (*)

compute node: NET MGMT

compute node: NET0

U23: port 30

U23: port 29

U30-31 (*)

compute node: NET MGMT

compute node: NET0

U23: port 28

U23: port 27

U29

spine switch: NET MGMT

U23: port 48

U28

spine switch: NET MGMT

U23: port 47

U22

leaf switch: NET MGMT

U23: port 46

U21

leaf switch: NET MGMT

U23: port 45

U19-20 (*)

compute node: NET MGMT

compute node: NET0

U23: port 26

U23: port 25

U17-18 (*)

compute node: NET MGMT

compute node: NET0

U23: port 24

U23: port 23

U15-16

compute node: NET MGMT

compute node: NET0

U23: port 22

U23: port 21

U13-14

compute node: NET MGMT

compute node: NET0

U23: port 20

U23: port 19

U11-12

compute node: NET MGMT

compute node: NET0

U23: port 18

U23: port 17

U09-10

management node: NET MGMT

management node: NET0

U23: port 16

U23: port 15

U07-08

management node: NET MGMT

management node: NET0

U23: port 14

U23: port 13

U05-06

management node: NET MGMT

management node: NET0

U23: port 12

U23: port 11

U03

ZFS storage appliance controller: NET MGMT

ZFS storage appliance controller: NET0

ZFS storage appliance controller: PCIE6-2

U23: port 10

U23: port 9

U23: port 6

U01

ZFS storage appliance controller: NET MGMT

ZFS storage appliance controller: NET0

ZFS storage appliance controller: PCIE6-2

U23: port 8

U23: port 7

U23: port 5

N/A

Oracle Support

U23: port 1

(*) – Indicates a rack unit designated as a flex bay. These rack units can contain compute nodes or storage nodes. The rack unit and port numbers assigned to flex bays only apply when a compute node is installed in that location.

(^) – Indicates a rack unit designated as a flex bay. These rack units can only contain storage nodes because of power constraints.