Private Cloud Appliance X10 Management Switch Ethernet Connections
This section applies to the Private Cloud Appliance X10 rack configuration, which uses Oracle Server X10 or Oracle Server X11 2U compute nodes. The table lists the cabling connections for the management switch. These are Ethernet connections intended for the internal administration network.
From Rack Unit | From Component and Port | To Management Switch Rack Unit and Port |
---|---|---|
N/A |
bastion/gateway |
U24: port 2 |
U39-40 (^) |
compute node: NET0 |
U24: port 19 |
U37-38 (*) |
compute node: NET0 |
U24: port 39 |
U35-36 (*) |
compute node: NET0 |
U24: port 38 |
U33-34 (*) |
compute node: NET0 |
U24: port 37 |
U31-32 (*) |
compute node: NET0 |
U24: port 36 |
U30 |
spine switch: NET MGMT |
U24: port 14 |
U29 |
spine switch: NET MGMT |
U24: port 13 |
U23 |
leaf switch: NET MGMT |
U24: port 34 |
U22 |
leaf switch: NET MGMT |
U24: port 33 |
U20-21 (*) |
compute node: NET0 |
U24: port 35 |
U18-19 (*) |
compute node: NET0 |
U24: port 21 |
U16-17 (*) |
compute node: NET0 |
U24: port 17 |
U14-15 (*) |
compute node: NET0 |
U24: port 15 |
U12-13 |
compute node: NET0 |
U24: port 12 |
U10-11 |
compute node: NET0 |
U24: port 10 |
U08-09 |
compute node: NET0 |
U24: port 8 |
U07 |
management node: NET0 |
U24: port 5 |
U06 |
management node: NET0 |
U24: port 32 |
U05 |
management node: NET0 |
U24: port 31 |
U03-04 |
ZFS storage appliance controller: NET0 |
U24: port 28 |
U03-04 |
ZFS storage appliance controller: PCIe 6-2 |
U24: port 29 |
U01-02 |
ZFS storage appliance controller: NET0 |
U24: port 25 |
U01-02 |
ZFS storage appliance controller: PCIe 6-2 |
U24: port 26 |
N/A |
Oracle Support |
U24: port 1 |
(*) – Indicates a rack unit designated as a flex bay. These rack units can contain compute nodes or storage nodes. The rack unit and port numbers assigned to flex bays only apply when a compute node is installed in that location.
(^) – Indicates a rack unit reserved for an expansion compute node. To maintain balanced availability domains, compute nodes must be installed in multiples of 3. The reserved slot allows for 6 compute nodes to be installed without sacrificing a second flex bay.