Private Cloud Appliance X9 Management Switch Ethernet Connections

This section applies to the Private Cloud Appliance X9 rack configuration, which uses Oracle Server X9-2 1U compute nodes. The table lists the cabling connections for the management switch. These are Ethernet connections intended for the internal administration network.

From Rack Unit From Component and Port To Management Switch Rack Unit and Port

--

bastion

U26: port 2

U41*

compute node: NET0

U26: port 42

U40*

compute node: NET0

U26: port 41

U39*

compute node: NET0

U26: port 40

U38*

compute node: NET0

U26: port 39

U37*

compute node: NET0

U26: port 38

U36*

compute node: NET0

U26: port 37

U35*

compute node: NET0

U26: port 36

U34*

compute node: NET0

U26: port 35

U32

leaf switch: NET MGMT

U26: port 14

U31

leaf switch: NET MGMT

U26: port 13

U25

spine switch: NET MGMT

U26: port 34

U24

spine switch: NET MGMT

U26: port 33

U23*

compute node: NET0

U26: port 23

U22*

compute node: NET0

U26: port 22

U21*

compute node: NET0

U26: port 21

U20*

compute node: NET0

U26: port 20

U19*

compute node: NET0

U26: port 19

U18*

compute node: NET0

U26: port 18

U17*

compute node: NET0

U26: port 17

U16*

compute node: NET0

U26: port 16

U15

compute node: NET0

U26: port 15

U14

compute node: NET0

U26: port 12

U13

compute node: NET0

U26: port 11

U12

compute node: NET0

U26: port 10

U11

compute node: NET0

U26: port 9

U10

compute node: NET0

U26: port 8

U09

compute node: NET0

U26: port 7

U08

compute node: NET0

U26: port 6

U07

management node: NET0

U26: port 5

U06

management node: NET0

U26: port 32

U05

management node: NET0

U26: port 31

U03

ZFS storage appliance controller: NET0

U26: port 28

U03

ZFS storage appliance controller: PCIe 6-2

U26: port 29

U01

ZFS storage appliance controller: NET0

U26: port 25

U01

ZFS storage appliance controller: PCIe 6-2

U26: port 26

N/A

PDU-A

U26: port 24

N/A

PDU-B

U26: port 43

N/A

Oracle Support

U26: port 1