Administrative Ethernet Port Cabling Tables X8M
Table 18-2 shows the cable connections from the servers to the gigabit Ethernet switch in a Recovery Appliance X8M full rack. The port numbers are the same in racks with fewer storage servers.
The Management Network Switch is located in rack unit 21 on Recovery Appliance X8M. Ethernet cables are blue.
In the following tables, Un denotes the unit height in the rack, where n is the number, such as U20. The cables used for the Management Network Switch are blue in color. The following tables are in this section:
Table 18-2 Ethernet Cabling for the Recovery Appliance X8M Full Racks
From Rack Unit(1) | Component | To Ethernet Port |
---|---|---|
U41 |
Storage server |
15 |
U39 |
Storage server |
1 |
U37 |
Storage server |
3 |
U35 |
Storage server |
5 |
U33 |
Storage server |
7 |
U31 |
Storage server |
9 |
U29 |
Storage server |
11 |
U27 |
Storage server |
13 |
U25 |
Storage server |
17 |
U23 |
Storage server |
21 |
U22 |
RDMA Network Fabric switch |
45 |
U20 |
RDMA Network Fabric switch |
46 |
U18 |
Storage server |
25 |
U17 |
Compute server |
27 |
U16 |
Compute server |
29 |
U14 |
Storage server |
31 |
U12 |
Storage server |
33 |
U10 |
Storage server |
35 |
U8 |
Storage server |
37 |
U6 |
Storage server |
39 |
U4 |
Storage server |
41 |
U2 |
Storage server |
43 |
Footnote 1 Un is the unit location in the rack, where n is the number.