Administrative Ethernet Port Cabling Tables X8M

Table 19-2 shows the cable connections from the servers to the gigabit Ethernet switch in a Recovery Appliance X8M full rack. The port numbers are the same in racks with fewer storage servers.

The Management Network Switch is located in rack unit 21 on Recovery Appliance X8M. Ethernet cables are blue.

In the following tables, Un denotes the unit height in the rack, where n is the number, such as U20. The cables used for the Management Network Switch are blue in color. The following tables are in this section:

Table 19-2 Ethernet Cabling for the Recovery Appliance X8M Full Racks

From Rack Unit(1) Component To Ethernet Port
U41 Storage server 15
U39 Storage server 1
U37 Storage server 3
U35 Storage server 5
U33 Storage server 7
U31 Storage server 9
U29 Storage server 11
U27 Storage server 13
U25 Storage server 17
U23 Storage server 21
U22 RDMA Network Fabric switch 45
U20 RDMA Network Fabric switch 46
U18 Storage server 25
U17 Compute server 27
U16 Compute server 29
U14 Storage server 31
U12 Storage server 33
U10 Storage server 35
U8 Storage server 37
U6 Storage server 39
U4 Storage server 41
U2 Storage server 43

Footnote 1 Un is the unit location in the rack, where n is the number.