Administrative Gigabit Ethernet Cabling Connections
Table 19-2 shows the cable connections from the servers to the gigabit Ethernet switch in a Recovery Appliance X7, X6, or X5 full rack. The port numbers are the same in racks with fewer storage servers. The Ethernet switch is located in rack unit 21. Ethernet cables are blue.
Table 19-2 Gigabit Ethernet Cabling for the Recovery Appliance X7, X6, or X5 Full Racks
From Rack Unit(1) | Component | To Ethernet Port |
---|---|---|
U41 |
Storage server |
15 |
U39 |
Storage server |
1 |
U37 |
Storage server |
3 |
U35 |
Storage server |
5 |
U33 |
Storage server |
7 |
U31 |
Storage server |
9 |
U29 |
Storage server |
11 |
U27 |
Storage server |
13 |
U25 |
Storage server |
17 |
U23 |
Storage server |
21 |
U22 |
InfiniBand leaf switch |
45 |
U20 |
InfiniBand leaf switch |
46 |
U18 |
Storage server |
25 |
U17 |
Compute server |
27 |
U16 |
Compute server |
29 |
U14 |
Storage server |
31 |
U12 |
Storage server |
33 |
U10 |
Storage server |
35 |
U8 |
Storage server |
37 |
U6 |
Storage server |
39 |
U4 |
Storage server |
41 |
U2 |
Storage server |
43 |
Footnote 1 Un is the unit location in the rack, where n is the number.