25 Error Messages
This appendix contains the hardware messages for Recovery Appliance. They are identical to the messages for Oracle Exadata Database Machine.
This appendix contains the following sections:
-
Power Supply/Converters Alert Messages: HALRT-00717 to HALRT-00800
-
Hard Disk and Flash Disk Alert Messages: HALRT-01015 to HALRT-01200
-
Accelerator/Controller Alert Messages: HALRT-01209 to HALRT-01300
-
Auto Service Request Alert Messages for Storage Servers: HALRT-02001 to HALRT-02013
-
HDD Controller Battery Alert Messages: HALRT-02101 to HALRT-02200
-
Generic Actions for Alert Messages: HALRT-10001 to HALRT-10500
-
Generic Actions for Alert Messages: HALRT-10503 to HALRT-11000
-
Generic Actions for Alert Messages: HALRT-11001 to HALRT-11100
See Also:
Oracle Database Error Messages for information about Oracle Database SNMP error messages
Contacting Oracle Support Services
Some messages recommend contacting Oracle Support Services to report a problem. To report a problem, sign in to My Oracle Support at http://support.oracle.com
and log a service request. You might also want to contact Oracle Support when Auto Service Request submits a service request.
When you contact Oracle Support Services, have the following information available:
-
The hardware, operating system, and release number of the operating system running Oracle Database.
-
The complete release number of Oracle Database, such as release 12.1.0.2.
-
All Oracle programs (with release numbers) in use when the error occurred.
-
If you encountered one or more error codes or messages, then the exact code numbers and message text, in the order in which they appeared.
-
The problem severity, according to the following codes:
-
1: Program not usable. Critical effect on operations.
-
2: Program usable. Operations severely restricted.
-
3: Program usable with limited functions. Not critical to overall operations.
-
4: Problem circumvented by customer. Minimal effect, if any, on operations.
-
You will also be expected to provide the following:
-
The name of your organization
-
Your name
-
Your Oracle Support ID number
-
Your telephone number
-
Rack master serial number
Generic Alert Messages: HALRT-00001 to HALRT-00500
- HALRT-00002, Chassis Intrusion - Physical Security Violation
-
Cause: Detected a Physical Security Violation on the chassis.
- HALRT-00003, Chassis Intrusion (Physical Security Violation) Event Cleared
-
Cause: Detected a clear event of Physical Security Violation on the chassis.
- HALRT-00007, CPU Configuration Error Cleared
-
Cause: Detected a clear event for a CPU configuration error.
- HALRT-00008, CPU Presence (Processor Presence detected)
-
Cause: Detected presence event for a new CPU.
- HALRT-00010, System Event Log (SEL) Full (Logging Disabled)
-
Cause: System event log detected to be full.
- HALRT-00011, ASR (Automatic System Recovery) Timer Expired
-
Cause: Automatic System Recovery timer expired.
- HALRT-00012, ASR (Automatic System Recovery) Reset Occurred
-
Cause: Automatic System Recovery reset occurred.
- HALRT-00013, ASR (Automatic System Recovery) Power Down Occurred
-
Cause: Automatic System Recovery was powered down.
- HALRT-00014, ASR (Automatic System Recovery) Power Cycle Occurred
-
Cause: Automatic System Recovery power was cycled.
- HALRT-00015, {0} Sensor Threshold state change: Sensor Component Name: {1} Sensor State: {2} Sensor Threshold Type: {3} Sensor Threshold Severity: {4} Sensor Value: {5} Sensor Threshold Value: {6} Sensor Additional Info: {7}
-
Cause: The sensor threshold state has changed.
- HALRT-00016, A {0} component is suspected of causing a fault. Component Name: {1} Fault class: {2} Fault certainty: {3} Fault message: {4} Trap Additional Info: {5}
-
Level Critical
- HALRT-00017, A {0} component fault has been cleared. Component Name: {1} Trap Additional Info: {2}
-
Level Clear
- HALRT-00018, A {0} sensor has detected an error. Component Name: {1} Trap Additional Info: {2}
-
Cause: An error was detected by a sensor.
- HALRT-00019, A {0} sensor has returned to its normal state. Component Name: {1} Trap Additional Info: {2}
-
Cause: The sensor has returned to its normal state.
- HALRT-00020, A field replaceable unit at {0} has been inserted into the system.
-
Cause: A unit was inserted into the system.
- HALRT-00021, A field replaceable unit at {0} has been removed from the system.
-
Cause: A unit was removed from the system.
- HALRT-00022, The component operational state has changed or is changing to disabled. Component Name: {0} Disable Reason: {1} Trap Additional Info: {2}
-
Cause: The operational state for a component has changed.
- HALRT-00023, The component operational state has changed or is changing to enabled. Component Name: {0} Trap Additional Info: {1}
-
Cause: The operational state for a component has changed.
- HALRT-00024, An error has been detected in the period before the operating system has taken control of the system.
-
Cause: An error was detected.
- HALRT-00025, The high availability component identified by {0} has changed state. Old HA State: {1} New HA State: {2} Trap Additional Info: {3}
-
Cause: The state for a high availability component has changed.
- HALRT-00026, An intrusion sensor has detected that someone may have physically tampered with the system.
-
Cause: A sensor has detected a change to the system.
Temperature Alert Messages: HALRT-00513 to HALRT-00600
- HALRT-00513, Under-Temperature Warning (Lower non-critical, going low).
-
Cause: The temperature was below the specified range.
- HALRT-00515, Under-Temperature Problem (Lower Critical - going low)
-
Cause: A low temperature problem was detected.
- HALRT-00517, Over-Temperature warning (Upper non-critical, going high)
-
Cause: The temperature was above the specified range.
- HALRT-00519, Over-Temperature Problem (Upper Critical - going high)
-
Cause: A high temperature was detected.
Power Supply/Converters Alert Messages: HALRT-00717 to HALRT-00800
Network Alert Messages: HALRT-00912 to HALRT-01000
- HALRT-00912, Infiniband port {0} indicates invalid state: {1}
-
Cause: InfiniBand device indicated an invalid state.
- HALRT-00913, InfiniBand port {0} indicates invalid rate: {1} Gps
-
Cause: InfiniBand device indicated invalid rate.
- HALRT-00915, InfiniBand port {0} is showing non-zero error counts
-
Cause: The error counts for
RcvErrors
andSymbolErrors
on the specified port were non-zero. A non-zero error count can be caused by a bad cable, or a cable that is not properly seated, or by a bad port on the HCA or switch. Manually disabling and enabling InfiniBand ports or resetting InfiniBand switches can also lead to these errors.
Hard Disk and Flash Disk Alert Messages: HALRT-01015 to HALRT-01200
These alert messages are in the range HALRT-01015 through HALRT-01200.
- HALRT-01015, Physical drive inserted on Adapter: {0} Device Id: {1}, Enclosure ID: {2}, Slot ID: {3}
-
Cause: The physical drive was inserted.
- HALRT-01016, Physical drive removed on Adapter: {0} Device ID: {1}, Enclosure ID: {2}, Slot ID: {3}
-
Cause: The physical drive was removed.
- HALRT-01017, Physical drive state changed from {0} to {1}. Adapter: {2} Device ID: {3}, Enclosure ID: {4}, Slot ID: {5}
-
Cause: The physical drive status has changed.
- HALRT-01018, FRU changed. Adapter: {0} Device ID: {1}, Enclosure ID: {2}, Slot ID: {3}, Enclosure ID: {4} FRU {5}
-
Cause: The field replaceable unit (FRU) was changed on the adapter.
- HALRT-01020, Physical drive not supported. Adapter: {0} Device ID: {1}, Enclosure ID: {2}, Slot ID: {3}
-
Cause: The physical drive is not supported on the adapter.
- HALRT-01021, Physical drive not certified. Adapter: {0} Device ID: {1}, Enclosure ID: {2}, Slot ID: {3}
-
Cause: The physical drive was not certified.
- HALRT-01024, Physical {0} disk error count is increasing. Disk: {1}, Serial Number: {2}, Slot Number: {3}
-
Level Critical
- HALRT-01025, Physical {0} disk error count is stable. Disk: {1}, Serial Number: {2}, Slot Number: {3}
-
Level Clear
- HALRT-01027, Flash celldisk {0} write performance is degraded. The supercap module on the Flash card may have failed. Flash disk name : {1} Disk serial number: {2} Slot number: {3}
-
Cause: The write performance for the flash cell disk was degraded.
- HALRT-01028, Flash celldisk {0} write performance problem has been resolved
-
Cause: The performance problem for the flash cell disk was resolved.
- HALRT-01029, Physical disk {0} could not be set to ONLINE automatically. Physical disk {0} firmware could not be upgraded.
-
Level Critical
- HALRT-01032, Physical disk {0} firmware successfully upgraded
-
Cause: The physical disk firmware was upgraded.
- HALRT-01035, Physical disks {0} firmware could not be upgraded. Inserted physical disks will be accepted because MS_ACCEPT_DISKFW_DIFFERENT is set to true.
-
Level Informational
- HALRT-01036, Oracle Exadata discovered the following problems in the device utilities: {0}
-
Cause: A problem has been discovered. The problem is one of the following:
-
Output has duplicate name.
-
Output has duplicate serial number.
-
Output has duplicate OS device name.
-
Cannot find device name for the disk with target ID.
-
- HALRT-01038, {0} output has duplicate serial number: {1}
-
Cause: The output had a duplicate serial number.
- HALRT-01039, {0} output has duplicate OS device name: {1}
-
Cause: The output had a duplicate operating system device name.
- HALRT-01040, Cannot find device name for the disk with target ID: {0}
-
Cause: The device was not found.
- HALRT-01041, The problems in the device utilities have been resolved.
-
Cause: The problem was resolved.
- HALRT-01042, {0} was replaced. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Warning
- HALRT-01043, {0} was replaced. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10} Flash Cache: {11} Flash Log {12}
-
Level Warning
- HALRT-01044, {0} failed. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01045, {0} entered predictive failure status. {1} was replaced. Status: {2} Manufacturer : {3} Model Number : {4} Size: {5} Serial Number : {6} Firmware: {7} Slot Number : {8} Cell Disk: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01046, {0} failed. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01047, {0} entered predictive failure status. {0} was replaced. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01048, {0} failed. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01049, {0} failed. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01050, {0} entered predictive failure status. {0} was replaced. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Cause: The system hard disk entered predictive failure.
- HALRT-01051, {0} failed. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}.
-
Level Critical
- HALRT-01052, {0} entered predictive failure status. {0} was replaced. Status: {1} Manufacturer : {2} Model Number : {3} Size: {4} Serial Number : {5} Firmware: {6} Slot Number : {7} Cell Disc: {9} Grid Disk: {10}
-
Level Critical
- HALRT-01053, The Oracle ASM drop operation on the following disk failed due to ORA-{0} ASM Disk Name: {1} ASM Diskgroup: {2} Grid Disk: {3} Cell Disk: {4} Physical Disk: {5} Physical Disk Status: {6}
-
Level Critical
- HALRT-01054, The Oracle ASM drop operation on the following disk failed due to ORA-{0} ASM Disk Name: {1} ASM Diskgroup: {2} Grid Disk: {3} Cell Disk: {4} Physical Disk: {5} Physical Disk Status: {6}
-
Level Critical
- HALRT-01055, The Oracle ASM rebalance operation on the following disk failed due to ORA-{0} ASM Disk Name: {1} ASM Diskgroup: {2} Grid Disk: {3} Cell Disk: {4} Physical Disk: {5} Physical Disk Status: {6}
-
Level Critical
- HALRT-01056, The Oracle ASM rebalance operation on the following disk resumed ORA-{0} ASM Disk Name: {1} ASM Diskgroup: {2} Grid Disk: {3} Cell Disk: {4} Physical Disk: {5} Physical Disk Status: {6}
-
Level Warning
- HALRT-01057, The Oracle ASM add operation on the following disk failed due to ORA-{0} ASM Disk Name: {1} ASM Diskgroup: {2} Grid Disk: {3} Cell Disk: {4} Physical Disk: {5} Physical Disk Status: {6}
-
Level Critical
- HALRT-01058, The Oracle ASM add operation on the following disk failed due to ORA-{0} ASM Disk Name: {1} ASM Diskgroup: {2} Grid Disk: {3} Cell Disk: {4} Physical Disk Name: {5} Physical Disk Status: {6}
-
Level Critical
- HALRT-01059, Oracle Exadata completed the rebalance operation triggered by the add operation on the following ASM disks. ASM Disk Name: {0} ASM Diskgroup: {1} Grid Disk: {2} Cell Disk: {3} Physical Disk: {4} Physical Disk Status : {5}
-
Level Clear
- HALRT-01060, Oracle Exadata completed the rebalance operation triggered by the drop operation on the following ASM disks. ASM Disk Name: {0} ASM Diskgroup: {1} Grid Disk: {2} Cell Disk: {3} Physical Disk: {4} Physical Disk Status : {5}
-
Level Warning
- HALRT-01061, {0} is ready to use. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11}
-
Level Clear
- HALRT-01062, {0} is ready to use. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Clear
- HALRT-01063, The Oracle ASM rebalance operation on the following disk failed as ASM rebalance operation is disabled. ASM Disk Name: {0} ASM Diskgroup: {1} Grid Disk: {2} Cell Disk: {3} Physical Disk: {4} Physical Disk Status : {5}
-
Level Critical
- HALRT-01106, All Logical drives are in WriteThrough caching mode. HDD disk controller battery needs to be replaced. Please contact Oracle Support.
-
Cause: The logical drive was found.
- HALRT-01107, Disk drive {0} is in WriteThrough caching mode. Write Performance on this drive will be affected. Please contact Oracle Support.
-
Cause: The disk drive was lost.
- HALRT-01108, Logical drive status changed. LUN: {0}. Status: {1}. Physical {2} disk: {3}. Slot Num: {4}. Serial Number: {5}. Cell Disk: {6}. Grid Disks: {7}
-
Cause: The logical drive status has changed.
- HALRT-01109, Disk controller battery temperature exceeded the threshold of {0} Celsius. All disk drives have been placed in WriteThrough caching mode. The flash drives are not affected. Batter ySerial Number: {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity: {4} Relative Charge {5} Ambient Temperature: {6}
-
Cause: The temperature exceeded the threshold.
- HALRT-01110, Logical drive found. It was empty. Failed creating cell disk and grid disks on it. LUN: {0}. Status: {1}. Physical: {2}. Slot Num: {3}. Serial Number: {4}
-
Cause: The logical drive was found.
- HALRT-01115, BGI completed with uncorrectable errors on Adapter {0} VD Target {1}
-
Cause: BGI completed with errors.
- HALRT-01117, LUN state changed on Adapter {0} VD Target {1} from {2} to {3}
-
Cause: The LUN state was changed.
- HALRT-01118, LUN bad block table cleared on Adapter {0} VD Target {1}
-
Cause: The LUN bad block table was cleared.
- HALRT-01123, {0} is rejected due to incorrect disk model. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Critical
- HALRT-01124, Hard Disk replaced. Status: {0} Manufacturer: {1} Model Number: {2} Size: {3} Serial Number: {4} Firmware: {5} Slot Number: {6} Cell Disk: {7} Grid Disk: {8}
-
Level Warning
- HALRT-01126, The full charge capacity of the disk controller battery has fallen below the minimum threshold of {0} mAh. All disk drives have been placed in WriteThrough caching mode. Disk write performance may be somewhat reduced. The flash drives are not affected.Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: The full charge capacity of the battery was below the threshold.
- HALRT-01127, All disk drives have been placed in WriteThrough caching mode. The flash drives are not affected. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: The cause could not be determined.
- HALRT-01128, Cell disk was missing and is recreated on the {0}. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Cause: The cell disk was missing, and has been recreated on the disk.
- HALRT-01130, {0} status changed to poor performance. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Cause: The hard disk or flash disk status changed to poor performance.
- HALRT-01131, {0} status changed to normal. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Warning
- HALRT-01132, {0} removed. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Error Count: {10} Last Failure: {11}
-
Level Critical
- HALRT-01133, {0} status changed to offline. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}.
-
Level Critical
- HALRT-01141, Flash Disk was replaced. Status: {0} Manufacturer: {1} Model Number: {2} Size: {3} Serial Number: {4} Firmware: {5} Slot Number: {6} Cell Disk: {7} Grid Disk: {8} Flash Cache: {9} Flash Log {10}
-
Level Warning
- HALRT-01143, All disk drives have been placed in WriteThrough caching mode. The controller has preserved cache for a disk drive for more than five minutes. The flash drives are not affected. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: The preserved cache was not turned off for more than five minutes.
- HALRT-01144, Cell disk was missing and is recreated on the {0}. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Cause: The cell disk was missing and has been recreated on the drive.
- HALRT-01145, Flash Disk status changed to predictive failure. Status: {0} Manufacturer: {1} Model Number: {2} Size: {3} Serial Number: {4} Firmware: {5} Slot Number: {6} Cell Disk: {7} Grid Disk: {8} Flash Cache: {9} Flash Log: {10}
-
Level Critical
- HALRT-01146, {0} entered poor performance status. The LUN {1} changed status to {2}. Status: {3} Manufacturer: {4} Model Number: {5} Size: {6} Serial Number: {7} Firmware: {8} Slot Number: {9} Cell Disk: {10} Grid Disk: {11} Flash Cache: {12} Flash Log: {13} Reason for poor performance: {14}
-
Cause: Flash disk status changed to
poor performance
.
- HALRT-01147, {0} status changed to normal. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11}
-
Level Warning
- HALRT-01148, Flash Disk removed. Status: {0} Manufacturer: {1} Model Number: {2} Size: {3} Serial Number: {4} Firmware: {5} Slot Number: {6} Cell Disk: {7} Grid Disk: {8} Flash Cache: {9} Flash Log: {10} Error Count: {11} Last Failure: {12}
-
Level Critical
- HALRT-01149, {0} status changed to offline. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11}
-
Level Warning
- HALRT-01150, Cell disk was missing and is recreated on the {0}.
-
Cause: The cell disk was missing, and has been recreated on the disk.
- HALRT-01153, Disk drive {0} is back in WriteBack caching mode.
-
Cause: The disk drive entered write back caching mode.
- HALRT-01154, Oracle Exadata Storage Server failed to auto-create cell disk and grid disks on the newly inserted physical disk. Physical Disk: {0} Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Cause: The server did not auto-create the cell disk or grid disks.
- HALRT-01155, All disk drives have been temporarily placed in WriteThrough caching mode because the disk controller battery was replaced. The flash drives are not affected. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: Disk controller battery was replaced.
- HALRT-01156, Previously missing {0} is found. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11}
-
Level Clear
- HALRT-01157, Previously missing {0} is found. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Clear
- HALRT-01159, {0} import failed. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Level Warning
- HALRT-01160, Failed to create LUN on {0}. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Level Informational
- HALRT-01161, All disk drives are back in WriteBack caching mode. Preserved cache has turned off. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: Disk drives returned to write back caching mode.
- HALRT-01162, All disk drives are in WriteBack caching mode. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: Disk drives were in write back caching mode.
- HALRT-01163, All disk drives are back in WriteBack caching mode. Battery has completed charging. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}.
-
Cause: Battery completed charging, and all disk drives returned to write back caching mode.
- HALRT-01164, All disk drives are in WriteBack caching mode. Battery Serial Number: {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: Disk drives were in write back caching mode.
- HALRT-01165, {0} can be replaced now. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Critical
- HALRT-01166, {0} can be replaced now. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk {9} Flash Cache {11} Flash Log {12}
-
Level Critical
- HALRT-01168, {0} was removed and inserted. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Level Informational
- HALRT-01169, {0} entered write-through caching mode. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Level Critical
- HALRT-01170, Failed to flush the write back flash cache. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Level Critical
- HALRT-01171, {0} entered confinement offline status. The LUN {1} changed status to {2}. CellDisk changed status to {3}. All subsequent I/Os on this disk are failed immediately. Confinement tests will be run on the disk to determine if the disk should be dropped. Status: {4} Manufacturer: {5} Model Number: {6} Size: {7} Serial Number: {8} Firmware: {9} Slot Number: {10} Cell Disk: {11} Grid Disk: {12} Reason for confinement: {13}
-
Cause: The hard disk was performing poorly, and entered confinement.
- HALRT-01172, {0} entered confinement offline status. The LUN {1} changed status to {15}. CellDisk changed status to {2}. All subsequent I/Os on this disk are failed immediately. Confinement tests will be run on the disk to determine if the disk should be dropped. Status: {4} Manufacturer: {5} Model Number: {6} Size: {7} Serial Number: {8} Firmware: {9} Slot Number: {10} Cell Disk: {11} Grid Disk: {12} Flash Cache: {13} Flash Log: {14} Reason for confinement: {15}
-
Cause: The flash disk was performing poorly, and entered confinement.
- HALRT-01173, {0} entered confinement status. The LUN {1} changed status to {2}. CellDisk changed status to {3}. Status: {4} Manufacturer: {5} Model Number: {6} Size: {7} Serial Number: {8} Firmware: {9} Slot Number: {10} Cell Disk: {11} Grid Disk: {12} Reason for confinement: {13}
-
Cause: The system disk entered confinement.
- HALRT-01174, {0} entered confinement status. The LUN {1} changed status to {2}. CellDisk changed status to {3}. Status: {4} Manufacturer: {5} Model Number: {6} Size: {7} Serial Number: {8} Firmware: {9} Slot Number: {10} Cell Disk: {11} Grid Disk: {12} Flash Cache: {13} Flash Log: {14} Reason for confinement: {15}
-
Cause: The disk entered confinement.
- HALRT-01176, The data disk from slot {1} was inserted into system slot {2} of the same Oracle Exadata storage server. Status: {3} Manufacturer: {4} Model Number: {5} Size: {6} Serial Number: {7} Firmware: {8} Slot Number: {9}
-
Level Warning
- HALRT-01177, The system disk from slot {0} was inserted into data slot {1} of the same Oracle Exadata storage server. Status: {2} Manufacturer: {3} Model Number: {4} Size: {5} Serial Number: {6} Firmware: {7} Slot Number: {8}
-
Level Warning
- HALRT-01178, The system disk from a different Oracle Exadata storage server was inserted in slot {0}. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Level Warning
- HALRT-01179, A data disk from a different Oracle Exadata storage server was inserted in system slot {0}. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}.
-
Level Warning
- HALRT-01181, {0} entered peer failure status. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Level Critical
- HALRT01182, {0} was removed before running the ALTER PHYSICALDISK DROP FOR REPLACEMENT command. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk {9}
-
Level Critical
- HALRT01183, {0} was removed before running the ALTER PHYSICALDISK DROP FOR REPLACEMENT command and inserted. {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Level Informational
- HALRT-01184, {0} automatically failed over to a spare disk. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Critical
- HALRT-01185, {0} automatically failed over to a spare disk. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Cause: The flash disk failed over to the spare disk.
- HALRT-01186, {0} was removed. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Level Critical
- HALRT-01187, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}
-
Level Warning
- HALRT--01188, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11}.Board Tracer Number : {12}
-
Level Warning
- HALRT--01189, Oracle Exadata Storage Server failed to auto-create cell disk and grid disks on the newly inserted physical disk. Physical Disk: {0} Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Board Tracer Number: {8}
-
Level Warning
- HALRT--01190, Previously missing {0} is found. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11} Board Tracer Number : {12}
-
Level Critical
- HALRT--01191, {0} status changed to normal. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11} Board Tracer Number : {12}
-
Level Warning
- HALRT--01192, {0} was removed and inserted. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Board Tracer Number : {9}
-
Level Informational
- HALRT--01193, {0} failed. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Board Tracer Number : {10}
-
Level Critical
- HALRT--01194, {0} entered predictive failure status. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11} Board Tracer Number : {12}
-
Level Critical
- HALRT--01195, {0} entered peer failure status. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11} Board Tracer Number: {12}
-
Level Critical
- HALRT--01196, {0} entered write-through caching mode. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache {10} Flash Log {11} Board Tracer Number : {12}
-
Level Critical
Accelerator/Controller Alert Messages: HALRT-01209 to HALRT-01300
- HALRT-01209, Alarm has been enabled by user for Adapter {0}.
-
Cause: An alarm was enabled for the adapter.
- HALRT-01210, Background initialization rate changed to {0} for Adapter {1}.
-
Cause: The background initialization rate was changed for the adapter.
- HALRT-01211, Controller {0} cache discarded due to memory/battery problems.
-
Cause: The controller cache was discarded due to memory or battery problems.
- HALRT-01212, Unable to recover Cache Data due to configuration mismatch for Adapter {0}.
-
Cause: Cache data was recovered due to a configuration mismatch.
- HALRT-01214, Controller cache discarded due to firmware version incompatibility for Adapter {0}
-
Cause: Controller cache was discarded because of incompatibility with the firmware version.
- HALRT-01215, Consistency Check rate changed to {0} for Adapter {1}.
-
Cause: The consistency check rate was changed for the adapter.
- HALRT-01216, Flash downloaded image corrupted for Adapter {0}.
-
Cause: The flash memory card image was corrupted.
- HALRT-01217, Flash erase error for Adapter {0}.
-
Cause: There was a flash erase error for the adapter.
- HALRT-01218, Flash timeout during erase for Adapter {0}.
-
Cause: The flash timed out during the erase procedure.
- HALRT-01220, Flashing image: {0} for Adapter {1}.
-
Cause: The controller flash was upgraded with a new image.
- HALRT-01221, Flash of new firmware image(s) complete for Adapter {0}.
-
Cause: The new firmware image was copied to flash.
- HALRT-01222, Flash programming error for Adapter {0}.
-
Cause: There was a flash programming error for the adapter.
- HALRT-01223, Flash timeout during programming for Adapter {0}.
-
Cause: The flash timed out while programming of the adapter.
- HALRT-01225, Rebuild rate changed to {0} for Adapter {1}.
-
Cause: The rebuild rate changed for the adapter.
- HALRT-01226, Alarm has been disabled by user for Adapter {0}.
-
Cause: The alarm for the adapter was disabled.
- HALRT-01227, Configuration cleared for Adapter {0}.
-
Cause: The configuration for the adapter was cleared.
- HALRT-01228, Factory defaults restored for Adapter {0}.
-
Cause: The factory default settings were restored for the adapter.
- HALRT-01229, HDD disk controller battery not Present for Adapter {0}.
-
Cause: The battery was not present for the adapter.
- HALRT-01230, New HDD disk controller battery Detected for Adapter {0}.
-
Cause: A new battery was detected for the adapter.
- HALRT-01231, HDD disk controller battery has been replaced for Adapter {0}.
-
Cause: The battery was replaced for the adapter.
- HALRT-01232, HDD disk controller battery temperature is high for Adapter {0}.
-
Cause: The battery temperature was high for the adapter.
- HALRT-01233, HDD disk controller battery voltage low for Adapter {0}.
-
Cause: The battery voltage was low for the adapter.
- HALRT-01234, HDD disk controller battery temperature is normal for Adapter {0}.
-
Cause: The battery temperature was normal for the adapter.
- HALRT-01235, HDD disk controller battery needs replacement, SOH Bad for Adapter {0}.
-
Cause: The battery needed replacement.
- HALRT-01236, HDD disk controller battery removed for Adapter {0}.
-
Cause: The battery was removed for the adapter.
- HALRT-01237, Current capacity of the HDD disk controller battery is below threshold for Adapter {0}.
-
Cause: The battery capacity was below the threshold for the adapter.
- HALRT-01238, Current capacity of the HDD disk controller battery is above threshold for Adapter {0}.
-
Cause: The battery capacity was above the threshold for the adapter.
- HALRT-01239, Bbu FRU changed for Adapter {0}.
-
Cause: The battery backup unit (BBU) field replacement unit (FRU) changed for the adapter.
- HALRT-01240, The disk controller battery is executing a learn cycle and may temporarily enter WriteThrough Caching mode as part of the learn cycle. Disk write throughput might be temporarily lower during this time. The flash drives are not affected. The battery learn cycle is a normal maintenance activity that occurs quarterly and runs for approximately 1 to 12 hours. Note that many learn cycles do not require entering WriteThrough caching mode. When the disk controller cache returns to the normal WriteBack caching mode, an additional informational alert will be sent. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}
-
Cause: Disk controller battery started the learn cycle.
- HALRT-01243, All disk drives have been placed in WriteThrough caching mode. The flash drives are not affected. The disk controller battery is executing an unscheduled learn cycle. Battery Serial Number: {1} Battery Type: {2} Battery Tempearature: {3} Full Charge Capacity: {4} Relative Charge: {5} Ambient Temperaturer: {6}.
-
Cause: An unscheduled learn cycle started.
Voltage Alert Messages: HALRT-01301 to HALRT-01400
Physical Disk Alert Messages: HALRT-01401 to HALRT-01500
- HALRT-01401, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Clear
- HALRT-01402, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11}
-
Level Clear
- HALRT-01403, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Clear
- HALRT-01404, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11}
-
Level Clear
- HALRT-01405, Oracle Exadata Storage Server failed to auto-create cell disk and grid disks on the newly inserted physical disk. Physical Disk: {0} Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7}
-
Level Clear
- HALRT-01406, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11} Board Tracer Number: {12}
-
Level Clear
- HALRT-01407, {0} was replaced. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9} Flash Cache: {10} Flash Log: {11} Board Tracer Number: {12}
-
Level Clear
- HALRT-01408, Oracle Exadata Storage Server failed to auto-create cell disk and grid disks on the newly inserted physical disk. Physical Disk: {0} Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Board Tracer Number: {8}
-
Level Clear
- HALRT-01409, {0} status changed to normal. Status: {1} Manufacturer: {2} Model Number: {3} Size: {4} Serial Number: {5} Firmware: {6} Slot Number: {7} Cell Disk: {8} Grid Disk: {9}
-
Level Clear
HDD Controller Battery Alert Messages: HALRT-02101 to HALRT-02200
- HALRT-02101, The HDD disk controller battery was dropped for replacement. All disk drives have been placed in WriteThrough caching mode. Disk write performance may be reduced. The flash drives are not affected Battery Serial Number : {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity : {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Warning
- HALRT-02102, HDD disk controller battery is {0}. All disk drives have been placed in WriteThrough caching mode. Disk write performance may be reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Critical
- HALRT-02103, All disk drives have been temporarily placed in WriteThrough caching mode because HDD disk controller battery is performing a learn cycle. Disk write performance may be somewhat reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Informational
- HALRT-02104, All disk drives have been temporarily placed in WriteThrough caching mode because HDD disk controller battery is charging. Disk write performance may be somewhat reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Informational
- HALRT-02105, The HDD disk controller battery was removed. All disk drives have been placed in WriteThrough caching mode. Disk write performance may be reduced. The flash drives are not affected.
-
Level Informational
- HALRT-02106,The HDD disk controller battery capacity was under threshold value of {0} mAh. All disk drives have been placed in WriteThrough caching mode. Disk write performance may be reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Critical
- HALRT-02107, The HDD disk controller battery temperature exceeded the threshold value of {6} Celsius. All disk drives have been placed in WriteThrough caching mode. Disk write performance may be reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Critical
- HALRT-02108, All disk drives have been temporarily placed in WriteThrough caching mode because HDD disk controller battery was replaced. Disk write performance may be somewhat reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Informational
- HALRT-02109, All disk drives have been placed in WriteThrough caching mode. Disk write performance may be reduced. The flash drives are not affected. Battery Serial Number : {1} Battery Type: {2} Battery Temperature: {3} Full Charge Capacity : {4} Relative Charge: {5} Ambient Temperature: {6}
-
Level Critical
- HALRT-02110, The HDD disk controller battery was removed before running the ALTER CELL BBU DROP FOR REPLACEMENT command. Battery Serial Number : {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity : {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Critical
- HALRT-02111, The HDD disk controller battery was replaced. All disk drives are in WriteBack caching mode. Battery Serial Number : {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity : {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Clear
- HALRT-02112, All disk drives are in WriteBack caching mode. Battery Serial Number : {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity : {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Clear
- HALRT-02113, All disk drives have been placed in WriteThrough caching mode. The controller has preserved cache for a disk drive for more than five minutes. The flash drives are not affected. Battery Serial Number : {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity : {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Critical
- HALRT-02114, The HDD disk controller battery is performing an unscheduled learn cycle. All disk drives have been placed in WriteThrough caching mode. The flash drives are not affected. Battery Serial Number : {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity : {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Informational
- HALRT-02115, Disk drive {0} is in WriteThrough caching mode. Write Performance on this drive will be affected.
-
Level Critical
- HALRT-02117, The HDD disk controller battery is performing a learn cycle. Battery Serial Number: {0} Battery Type: {1} Battery Temperature: {2} Full Charge Capacity: {3} Relative Charge: {4} Ambient Temperature: {5}
-
Level Informational
Generic Actions for Alert Messages: HALRT-10001 to HALRT-10500
- HALRT-10001
-
Cause: There was a nonerror change for a hardware status, such as a return to normal status.
- HALRT-10076
-
Cause: The Oracle ASM disks associated with the grid disks on the physical disk were successfully dropped, and a blue "OK to Remove LED" was lit on the disk to indicate it is safe to remove the disk.
- HALRT-10081
-
Cause: The hard disk demonstrated temporary poor performance. The disk has been confined and is in an offline state.