Single-Phase Power Distribution Unit Cabling Connections RA21
Table 17-3 shows the cable connections from the power distribution units (PDUs) to the rack units in an Oracle Zero Data Loss Recovery Appliance RA21 full rack. The destinations and the cable lengths are the same in racks with fewer storage servers. The cables terminate at PDU-A on the left and are routed to the right to enter the cable management arm (CMA). The cables are bundled in groups of four.
Table 17-3 Single-Phase PDU Cabling for the Recovery Appliance RA21 Full Racks
Rack Unit(1) | PDU-A | PDU-B | Cable Length |
---|---|---|---|
U41 |
G4-6 |
G1-0 |
3 meters |
U39 |
G4-4 |
G1-2 |
3 meters |
U37 |
G5-1 |
G0-5 |
3 meters |
U35 |
G1-5 |
G4-1 |
3 meters |
U33 |
G2-6 |
G3-0 |
2 meters |
U31 |
G3-3 |
G2-3 |
3 meters |
U29 |
G3-6 |
G2-0 |
3 meters |
U27 |
G3-2 |
G2-4 |
3 meters |
U25 |
G4-1 |
G1-5 |
3 meters |
U23 |
G5-0 |
G0-6 |
3meters |
U22* |
G1-6 |
G4-0 |
2 meters |
U21* |
G0-4 |
G5-2 |
2 meters |
U20* |
G0-3 |
G5-3 |
2 meters |
U18 |
G4-2 |
G1-4 |
3 meters |
U17* |
G1-2 |
G4-4 |
3 meters |
U16* |
G1-4 |
G4-2 |
2 meters |
U14 |
G2-1 |
G3-5 |
3 meters |
U12 |
G2-0 |
G3-6 |
3 meters |
U10 |
G2-3 |
G3-3 |
3 meters |
U8 |
G2-4 |
G3-2 |
3 meters |
U6* |
G1-3 |
G4-3 |
3 meters |
U4* |
G0-2 |
G5-4 |
3 meters |
U2* |
G0-5 |
G5-1 |
3 meters |
U1* |
G2-5 |
G3-1 |
3 meters |
Footnote 1 Un is the unit location in the rack, where n is the number.
* These items are required for all Recovery Appliances.