6 Specifications

This chapter provides information regarding the physical, electrical, environmental, and connector specifications of the Acme Packet 3900.

Environmental, Safety, and Regulatory Certifications

For information regarding safety and regulatory certifications applicable to the Acme Packet 3900, refer to the Acme Packet Platforms Safety and Compliance Guide.

Physical Specifications

System Chassis Specifications

This table lists the physical dimensions and weight of the Acme Packet 3900 chassis.

Specification Description
Height 1.72” (4.37 cm) (1U)
Width 17.10” (43.43 cm) (+ mounting ear width: 19” (48.26 cm))
Depth 15.75” (40.10 cm) (+ mounting slide bar depth)
Weight approximately 14.2 lbs (6.44 kg), fully loaded

AC Power Supply Physical Dimensions

This table lists the physical dimensions and weight of the Acme Packet 3900 AC power supply.

Specification Description
Height 1.58” (4.01 cm)
Width 3.402” (8.64 cm)
Depth 9.33” (23.70 cm)
Weight 2.34 lbs. (1.06 kg)

Note:

This equipment is intended for installation in locations where National Electrical Code (NEC) applies.

DC Power Supply Physical Dimensions

This table lists the physical dimensions and weight of the Acme Packet 3900 DC power supply.

Specification Description
Height 1.58” (4.01 cm)
Width 3.4” (8.63 cm)
Depth 9.33” (23.70 cm)
Weight 2.34 lbs. (1.06 kg)

Note:

This equipment is intended for installation in Network Telecommunication Facilities.

Fan Module Specifications

This table lists the fan module specifications for the Acme Packet 3900.

Specification Description
Number of Fans 2
Total Maximum Airflow 40 CFM

Electrical Specifications

Refer to the following tables for information regarding the electrical specifications.

Power Supply Input Circuit Fuse Requirements

This table lists the input circuit fuse and cable size requirements.

Power Circuit Fuse Rating Power Cable Size
120 VAC 15 AMP 18 AWG
240 VAC 7.5 AMP 18 AWG
-48 VDC 10 AMP 10 AWG

Environmental Specifications

Oracle recommends that you follow the environmental guidelines in the following table.

Specification Description
Temperature

The Acme Packet 3900 is required to operate within the temperature range of:

0° C to +40° C, 32° F to 104° F (operating)

-20° C to +65° C, -4° F to 149° F (storage)

Relative Humidity Operating conditions of 10% to 85% humidity under non-condensing operating conditions
Maximum Altitude The Acme Packet 3900 is required to operate below the maximum altitude of 10,000 feet.
Air Flow 40 CFM front to back
Power Dissipation 160W typical 220W maximum

Connector Specifications

Refer to the following table for information about the connector specifications.

Specification Description
AC Connector Port The IEC lead connector port on each power supply accepts a 3-lead IEC-60320 C14 connector for AC power installations (2).
RJ45/Management Ethernet Ports The 3 x 8-pin RJ45 10/100/1000BaseT ports are compliant with IEEE's 802.3, 802.3u, and 802.3ab.
RS232/Serial Port The RS232 serial port uses an 8-pin RJ45 connector that supports RS232 protocol.
1 GbE Media Ports The four 1GbE fiber optic connection ports (P0-P3) are implemented as SFP sockets. Duplex LC or copper SFPs may be used.
Terminal Block Connections The terminal block connections accept a bare (tinned) wire for DC power installations on each DC power supply (2).
DC Input Connector The Input connector on each DC power supply is a 2-circuit plug.
RJ48C T1/E1 Ports (Optional) Mechanical Arrangement: 4 Miniature 8-position jacks.

Usage: 1.544 Mbps digital services.

Electrical Network Connection: T&R, T1 R1, conductors 7 and 8provide cable shield integrity.

Optical Transceiver Interface Module Specification

Refer to the following table for information about the optical specifications of the optical transceivers.

Specification Single Mode (SX) Fiber Module Multi Mode (LX) Fiber Module
Wavelength λ 1310 nm 850 nm
Laser Type VCSEL VCSEL
Fiber type / Transmission Distance

0.5 to 550 m — 50 μm MMF

0.5 to 550 m — 62.5 μm MMF

300 m