4.135 chg-shlf

Use this command to change the Shelf FAN bit for an equipment shelf in the database, based on whether the shelf is equipped with a FAN unit or not.

Parameters

loc (mandatory)
The location of the shelf.
Range:
1200, 1300, 2100, 2200, 2300, 3100, 3200, 3300, 4100, 4200, 4300, 5100, 5200, 5300, 6100, 6200, 6300
fan (optional)
This parameter turns ON/OFF the FAN bit. If it is turned ON, the FAN power for this shelf will be added to the Frame Power Budget.
Range:
off - Shelf is not equipped with a FAN unit
on - Shelf is currently equipped with a FAN unit

Example

chg-shlf:loc=1200:fan=on

chg-shlf:loc=1200:fan=off

Dependencies

The frame and shelf values of the shelf location parameter (loc) must be within the valid range (xyzz, where x=frame and y=shelf; zz is always 00 for this command).

The specified shelf location must have been configured previously.

A shelf cannot be provisioned at location 1100. This location is reserved for the control shelf.

The Shelf FAN bit cannot be turned OFF if EPMB, SLIC or E5-APP-B card(s) are provisioned in the shelf.

Notes

None

Output

chg-shlf:loc=1200:fan=on

    tekelecstp 03-09-12 11:11:28 EST  EAGLE 45.0.0
    ENT-SHLF: MASP A - COMPLTD
;
chg-shlf:loc=1200:fan=off

    tekelecstp 03-09-12 11:11:28 EST  EAGLE 45.0.0
    ENT-SHLF: MASP A - COMPLTD 
;