4.321 ent-lg-event

Use this command to create a new LG event. The command class is TKLC_INTERNAL inheriting properties of DEBUG class. The Load Generator is supported on IPSG, IPLHC, IPGHC and SS7HC GPLs.

Parameters

dir (mandatory)
Type of Event (Tx or Rx)
Range:
Tx
Transmit Event
Rx
Receive Event
dpc (mandatory)
ANSI destination point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm). The prefix subfield indicates a private point code (prefix-ni-nc-ncm).
Synonym:
dpca
Range:
p-, 000-255, *

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p-

The asterisk value (*) is not valid for the ni subfield.

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

dpc/dpca/dpci/dpcn/dpcn24 (mandatory)
Destination point code
dpci (mandatory)
ITU international destination point code with subfields zone-area-id. The prefix subfield indicates a spare point code, private point code, or private and spare point code (prefix-zone-area-id).
Range:
s-, p-, ps-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

dpcn (mandatory)
ITU national destination point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code, private point code, or private and spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, p-, ps-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

dpcn24 (mandatory)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp). The prefix indicates a private point code (prefix-msa-ssa-sp).
Range:
p-, 000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p

msa—000–255

ssa—000–255

sp—000–255

event (mandatory)
Range:
ayyyyyyyyy Up to 10 alphanumeric characters; the first character must be a letter
h0h1 (mandatory)
SNM Type
Range:
tfa
tfp
tfc
tfr
rct
upu
opc (mandatory)
ANSI originating point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Range:
p-, 000-255, *

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p-

The asterisk value (*) is not valid for the ni subfield.

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

opc/opca/opci/opcn/opcn24 (mandatory)
Originating Point Code
opci (mandatory)
ITU international originating point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s-, p-, ps-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

opcn (mandatory)
ITU national originating point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4,prefix-m1-m2-m3-m4-gc).
Range:
s-, p-, ps-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

opcn24 (mandatory)
24-bit ITU national originating point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
p-, 000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p

msa—000–255

ssa—000–255

sp—000–255

si (mandatory)
MSU Service Indicator
Range:
0 - 15

SI value:

0 = SNM

1,2, 6-12, 14 = TEST

3 = SCCP

4 = TUP

5 = ISUP

13 = BICC

15 = H248

cause (optional)
Cause Code for UPUs
Range:
0 - 15
Default:
0
class (optional)
Internal or External
Range:
int
Internal
cnglvl (optional)
Congestion Level for TFCs
Range:
0 - 3
Default:
0
cpc (optional)
ANSI capability point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
cpca
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

cpc/cpca/cpci/cpcn/cpcn24 (optional)
Capability point code. The code used by the SS7 protocol to identify a group of functionally related STPs in the signaling network to which the STP belongs.
cpci (optional)
Range:
s-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

Default:
No change to existing point code value.
cpcn (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnnprefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

Default:
No change to existing point code value.
cpcn24 (optional)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa—000–255

ssa—000–255

sp—000–255

Default:
No change to existing point code value.
egta (optional)
End global title address. The end of a range of global title digits.
Range:
1 - 21
maxcic (optional)
Maximum CIC Selector
Range:
0 - 4294967295
Default:
4294967295
maxsize (optional)
Maximum Service Message SIF Size
Range:
0 - 4095
maxsls (optional)
Maximum SLS selector
Range:
0–255 -ANSI

0-15 -ITU

Default:
255 -ANSI

15 -ITU

mincic (optional)
Minimum CIC Selector
Range:
0 - 4294967295
Default:
0
minsize (optional)
Minimum Service Message SIF Size
Range:
0 - 4095
Default:
60 -SCCP MSUs

40 -other MSUs

System Default:
0
minsls (optional)
Minimum SLS Selector
Range:
0–255 -ANSI

0-15 -ITU

Default:
0
priority (optional)
Service Message Priority
Range:
0 - 3
Default:
0
ri (optional)
GTT or SSN
Range:
gtt
ssn
sclass (optional)
Range:
0 - 1
sgta (optional)
Start of global title address. The beginning of a range of global title digits.
Range:
1 - 21
ssn (optional)
Subsystem number. The application’s subsystem number. This attribute is composed of the decimal representation of the 1-byte field used in the SS7 protocol.
Range:
2 - 255
Default:
5
System Default:
0
tt (optional)
Translation type.
Range:
0 - 255
Default:
100
type (optional)
Event Type
Range:
MSU
Default:
MSU
usrid (optional)
User ID for UPUs
Range:
0 - 15
Default:
5
System Default:
0

Example

ent-lg-event:event=txisup1:dir=tx:type=msu:si=5:dpc=2-2-2:opc=1-1-1

ent-lg-event:event=txisup1:dir=tx:si=5:dpc=4-4-4:opc=3-3-3

ent-lg-event:event=rxisup1:dir=rx:dpc=3-3-3

Dependencies

If the mincic/maxcic parameter is specified, the si parameter must be 4 (tup), 5 (isup) or 13 (bicc).

If the tt/ssn/sgta/egta parameter is specified, the si=3 (sccp) parameter must be specified.

If the h0h1/cnglvl/cause/usrid/cpc parameter is specified, the si=0 (snm)  parameter must be specified.

When failed to read LG Event table.

The event name specified shouldn't be an Eagle reserved name

The event and dir parameters must be specified.

The dpc parameter is mandatory with Rx event type

The opc, dpc, and si parameters are mandatory with Tx event.

The h0h1 parameter is mandatory for si=0 (snm) Tx event.

The mincic specified must be less than maxcic.

The minsize specified must be less than maxsize.

The minsls specified must be less than maxsls.

The value specified for the event parameter cannot already exist in the LG Event table.

ITU SLS must be less than 15.

The LG Event Table cannot be full.

A valid SIF size must be specified with SI value.

The same  dpc parameter cannot be assigned to more than one Event of Rx type.

When other optional parameters are specified with Rx event

When sgta/egta/tt parameters are specified with RI=SSN for Tx event

The network type for the opc and dpc parameters must match.

If the ri=gt parameter is specified, then the sgta/egta  parameters must be specified.

The lengths of the sgta and egta parameters must match.

The egta and sgta parameters must be specified together in the command.

The value specified for the egta parameter must be greater than or equal to the value specified for the sgta parameter.

Notes

Mandatory and optional event parameters can be organized into two groups: generic and event type specific parameters. The generic parameters are applicable to any event type whereas event type specific are applicable only to a specific event type.

Generic event parameters are shown below:

Table 4-25 ENT-LG-EVENT Generic Parameters

Parameter

Description

Mand/Opt

Applicable Event Direction

Valid Values

event

event name

M

Any

dir

transmit or receive

M

Any

Tx, Rx

class

internal or external

O

Tx

INT

Default : INT

type

event type (msu)

O

Any

MSU

Default: MSU

Configurable parameters specific to each type of event are shown below:

Common MSU related configuration parameters when DIR (direction) parameter is Rx, are as follows:

Table 4-26 ENT-LG-EVENT Rx MSU Event Type common Parameters

Parameter

Description

Mand/Opt

Valid Values

dpca

Destination PC (ANSI)

M

dpci

Destination PC (ITU)

M

dpcn

Destination PC (ITU National)

M

dpcn24

Destination PC (24 bit ITU national)

M

Common MSU related configuration parameters when DIR (direction) parameter is Tx, are as follows:

Table 4-27 ENT-LG-EVENT Tx MSU Event Type common Parameters

Parameter

Description

Mand/Opt

Valid Values

dpca

Destination PC (ANSI)

M

dpci

Destination PC (ITU)

M

dpcn

Destination PC (ITU National)

M

dpcn24

Destination PC (24 bit ITU national)

M

opca

Origination PC (ANSI)

M

opci

Origination PC (ITU)

M

opcn

Origination PC (ITU National)

M

opcn24

Origination PC (24 bit ITU national)

M

priority

Service message priority

O

minsls

Minimum SLS selector

O

maxsls

Maximum SLS selector

O

minsize

Minimum service message SIF size

O

0 – 4095

maxsize

Maximum service message SIF size

O

0 – 4095

si

MSU service indicator

M

0-SNM,

1,2, 6-12, 14 - TEST

3-SCCP,

4-TUP,

5-ISUP,

13-BICC

15-H248

For MSU event type, Service indicators (SI) can have different formats, and consequently unique parameters. Following tables list these parameters related to MSU event type and SI.

Table 4-28 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 0)

Para meter

Description

Mand/Opt

Valid Values

h0h1

SNM type

M

TFA, TFP, TFC, TFR, RCT or UPU

cpca

concerned destination (ANSI)

O

cpci

concerned destination (ITU)

O

cpcn

concerned destination (ITU National)

O

cpcn24

concerned destination (24 bit ITU National)

O

cnglvl

congestion level for TFCs

O

0-3

cause

cause code for UPUs

O

0-15

usrid

user ID for UPUs

O

0-15

Table 4-29 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 1, 2, 6-12, 14, 15)

Parameter

Description

Mand/Opt

Valid Values

None

Table 4-30 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 3)

Parameter

Description

Mand/Opt

Valid Values

tt

Translation Type

O

0 – 255

ssn

Sub System Number

O

0 – 255

sgta

Start of global title address

O

1-21 digits

egta

End of global title address

O

1-21 digits

sclass

Class of service

O

0 – 1

ri

Routing Indicator (GT or SSN)

O

GT, SSN

Table 4-31 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 4, 5, 13)

Parameter

Description

Mand/Opt

Valid Values

mincic

Minimum CIC selector

O

 0..4294967295

maxcic

Maximum CIC selector

O

 0..4294967295

Output