4.321 ent-lg-event
Use this command to create a new LG event. The command class is TKLC_INTERNAL inheriting properties of DEBUG class. The Load Generator is supported on IPSG, IPLHC, IPGHC and SS7HC GPLs.
Parameters
- dpc (mandatory)
- ANSI destination point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm). The prefix subfield indicates a private point code (prefix-ni-nc-ncm).
- Synonym:
- dpca
- Range:
- p-, 000-255, *
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
prefix—p-
The asterisk value (*) is not valid for the ni subfield.
When
chg-sid:pctype=ansi
is specified, ni = 000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni = 001–005.When
chg-sid:pctype=ansi
is specified, nc = 000 is valid if ni = 006–255.The point code 000-000-000 is not a valid point code.
- dpci (mandatory)
- ITU international destination point code with subfields zone-area-id. The prefix subfield indicates a spare point code, private point code, or private and spare point code (prefix-zone-area-id).
- dpcn (mandatory)
- ITU national destination point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code, private point code, or private and spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
- dpcn24 (mandatory)
- 24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp). The prefix indicates a private point code (prefix-msa-ssa-sp).
- opc (mandatory)
- ANSI originating point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
- Range:
- p-, 000-255, *
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
prefix—p-
The asterisk value (*) is not valid for the ni subfield.
When
chg-sid:pctype=ansi
is specified, ni = 000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni = 001–005.When
chg-sid:pctype=ansi
is specified, nc = 000 is valid if ni = 006–255.The point code 000-000-000 is not a valid point code.
- opci (mandatory)
- ITU international originating point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
- opcn (mandatory)
- ITU national originating point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4,prefix-m1-m2-m3-m4-gc).
- opcn24 (mandatory)
- 24-bit ITU national originating point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
- cpc (optional)
- ANSI capability point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
- Synonym:
- cpca
- Range:
- 000-255
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
When
chg-sid:pctype=ansi
is specified, ni = 000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni = 001–005.When
chg-sid:pctype=ansi
is specified, nc = 000 is valid if ni = 006–255.The point code 000-000-000 is not a valid point code.
- cpc/cpca/cpci/cpcn/cpcn24 (optional)
- Capability point code. The code used by the SS7 protocol to identify a group of functionally related STPs in the signaling network to which the STP belongs.
- cpcn (optional)
- ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
- cpcn24 (optional)
- 24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Example
ent-lg-event:event=txisup1:dir=tx:type=msu:si=5:dpc=2-2-2:opc=1-1-1
ent-lg-event:event=txisup1:dir=tx:si=5:dpc=4-4-4:opc=3-3-3
ent-lg-event:event=rxisup1:dir=rx:dpc=3-3-3
Dependencies
If the mincic/maxcic parameter is specified, the si parameter must be 4 (tup), 5 (isup) or 13 (bicc).
If the tt/ssn/sgta/egta parameter is specified, the si=3 (sccp) parameter must be specified.
If the h0h1/cnglvl/cause/usrid/cpc parameter is specified, the si=0 (snm) parameter must be specified.
When failed to read LG Event table.
The event name specified shouldn't be an Eagle reserved name
The event and dir parameters must be specified.
The dpc parameter is mandatory with Rx event type
The opc, dpc, and si parameters are mandatory with Tx event.
The h0h1 parameter is mandatory for si=0 (snm) Tx event.
The mincic specified must be less than maxcic.
The minsize specified must be less than maxsize.
The minsls specified must be less than maxsls.
The value specified for the event parameter cannot already exist in the LG Event table.
ITU SLS must be less than 15.
The LG Event Table cannot be full.
A valid SIF size must be specified with SI value.
The same dpc parameter cannot be assigned to more than one Event of Rx type.
When other optional parameters are specified with Rx event
When sgta/egta/tt parameters are specified with RI=SSN for Tx event
The network type for the opc and dpc parameters must match.
If the ri=gt parameter is specified, then the sgta/egta parameters must be specified.
The lengths of the sgta and egta parameters must match.
The egta and sgta parameters must be specified together in the command.
The value specified for the egta parameter must be greater than or equal to the value specified for the sgta parameter.
Notes
Mandatory and optional event parameters can be organized into two groups: generic and event type specific parameters. The generic parameters are applicable to any event type whereas event type specific are applicable only to a specific event type.
Generic event parameters are shown below:
Table 4-25 ENT-LG-EVENT Generic Parameters
Parameter |
Description |
Mand/Opt |
Applicable Event Direction |
Valid Values |
event |
event name |
M |
Any |
|
dir |
transmit or receive |
M |
Any |
Tx, Rx |
class |
internal or external |
O |
Tx |
INT Default : INT |
type |
event type (msu) |
O |
Any |
MSU Default: MSU |
Configurable parameters specific to each type of event are shown below:
Common MSU related configuration parameters when DIR (direction) parameter is Rx, are as follows:
Table 4-26 ENT-LG-EVENT Rx MSU Event Type common Parameters
Parameter |
Description |
Mand/Opt |
Valid Values |
dpca |
Destination PC (ANSI) |
M |
|
dpci |
Destination PC (ITU) |
M |
|
dpcn |
Destination PC (ITU National) |
M |
|
dpcn24 |
Destination PC (24 bit ITU national) |
M |
Common MSU related configuration parameters when DIR (direction) parameter is Tx, are as follows:
Table 4-27 ENT-LG-EVENT Tx MSU Event Type common Parameters
Parameter |
Description |
Mand/Opt |
Valid Values |
dpca |
Destination PC (ANSI) |
M |
|
dpci |
Destination PC (ITU) |
M |
|
dpcn |
Destination PC (ITU National) |
M |
|
dpcn24 |
Destination PC (24 bit ITU national) |
M |
|
opca |
Origination PC (ANSI) |
M |
|
opci |
Origination PC (ITU) |
M |
|
opcn |
Origination PC (ITU National) |
M |
|
opcn24 |
Origination PC (24 bit ITU national) |
M |
|
priority |
Service message priority |
O |
|
minsls |
Minimum SLS selector |
O |
|
maxsls |
Maximum SLS selector |
O |
|
minsize |
Minimum service message SIF size |
O |
0 – 4095 |
maxsize |
Maximum service message SIF size |
O |
0 – 4095 |
si |
MSU service indicator |
M |
0-SNM, 1,2, 6-12, 14 - TEST 3-SCCP, 4-TUP, 5-ISUP, 13-BICC 15-H248 |
For MSU event type, Service indicators (SI) can have different formats, and consequently unique parameters. Following tables list these parameters related to MSU event type and SI.
Table 4-28 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 0)
Para meter |
Description |
Mand/Opt |
Valid Values |
h0h1 |
SNM type |
M |
TFA, TFP, TFC, TFR, RCT or UPU |
cpca |
concerned destination (ANSI) |
O |
|
cpci |
concerned destination (ITU) |
O |
|
cpcn |
concerned destination (ITU National) |
O |
|
cpcn24 |
concerned destination (24 bit ITU National) |
O |
|
cnglvl |
congestion level for TFCs |
O |
0-3 |
cause |
cause code for UPUs |
O |
0-15 |
usrid |
user ID for UPUs |
O |
0-15 |
Table 4-29 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 1, 2, 6-12, 14, 15)
Parameter |
Description |
Mand/Opt |
Valid Values |
None |
Table 4-30 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 3)
Parameter |
Description |
Mand/Opt |
Valid Values |
tt |
Translation Type |
O |
0 – 255 |
ssn |
Sub System Number |
O |
0 – 255 |
sgta |
Start of global title address |
O |
1-21 digits |
egta |
End of global title address |
O |
1-21 digits |
sclass |
Class of service |
O |
0 – 1 |
ri |
Routing Indicator (GT or SSN) |
O |
GT, SSN |
Table 4-31 ENT-LG-EVENT Tx MSU Event Type Specific Parameters (SI = 4, 5, 13)
Parameter |
Description |
Mand/Opt |
Valid Values |
mincic |
Minimum CIC selector |
O |
0..4294967295 |
maxcic |
Maximum CIC selector |
O |
0..4294967295 |
Output
Related Topics