4.320 ent-lg-engine
Use this command to create an LG engine. An LG Engine is associated with a single LG Card. The command class is TKLC_INTERNAL inheriting properties of DEBUG class. The Load Generator is supported on IPSG, IPLHC, IPGHC and SS7HC GPLs.
Parameters
- loc (mandatory)
- The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
- port (optional)
- The signaling link on the card specified in the loc parameter. The links can be specified in any sequence or pattern.
- Synonym:
- link
- Range:
- a, b, a1 - a31, b1 - b31
Not all card types support all link parameter values.
See Summary of Range Values for :link Parameter for valid link parameter range values for each type of card that can have a location specified in the loc parameter.
Example
ent-lg-engine:engine=txengine1:loc=1302:event=txisup1:port=a:txrate=100
ent-lg-engine:engine=rxengine1:loc=1302:event=rxisup1:action=cap
ent-lg-engine:engine=txengine2:loc=1302:event=txisup2:action=pbk:rxengine=rxengine1
Dependencies
The value specified for the engine parameter cannot already exist in the LG Engine table.
The LG Engine table is corrupt or cannot be found.
The number of engines associated with a card should not exceed the max limit.
The number of events associated with a engine should not exceed the max limit.
The txrate parameter cannot be specified with the parameter event of Rx type.
The action parameter of type PBK can only be assigned to Tx event direction.
The engine name specified shouldn't be an Eagle reserved name
The action parameter of type SNK/RET/RETL2/CONG/CAP can only be assigned to RX event direction.
The card location specified in the loc parameter must be of a provisioned LG card.
The port specified in the command must be provisioned.
The rxengine parameter cannot be specified with the action parameter of type other than PBK.
The specifiedRx engine parameter value must be associated with the card.
The Rxengine specified must pre-exist in the LG Engine table.
Engine specified in RxEngine parameter must of Rx Type.
The LG Event name specified in the command must exist in the table
The LG Engine table cannot already be full.
SIF Size > 272 not supported on ss7hc
The Rx Event can not be associated to more than one Engine on the same LG card
The LG Card and Event specified in the command must belong to same network
The port parameter cannot be specified with the parameter event of Rx type.
Output