4.11 act-lg-engine

Use this command to activate LG event generation/reception on an LG engine hosted on a LG card.

The command class is TKLC_INTERNAL inheriting properties of DEBUG class. The Load Generator is supported on IPSG, IPLHC, IPGHC and SS7HC GPLs.

Parameters

dir (optional)

Traffic Direction.

Range:
Rx
 Receive Direction
Tx
 Transmit Direction
All
Both in Tx and Rx directions
Default:
All
engine (optional)
Range:
ayyyyyyyyy

Up to 10 alphanumeric characters; the first character must be a letter.

loc (optional)
The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
test (optional)
Send Single MSU
Range:
yes

Example

act-lg-engine:loc=1301

act-lg-engine:engine=txengine1

act-lg-engine:loc=1301:dir=tx

act-lg-engine:engine=txengine1:test=yes

Dependencies

The engine name specified must pre-exist in the LG Engine table.

The loc parameter cannot be specified with the engine parameter.

Atleast one optional parameter must be specified.

The card location specified in the loc parameter must be of a provisioned LG card.

DIR parameter can only be specified along with LOC parameter.

Activating the state of an LG object that is already activated or deactivating the state of an LG object that is already deactivated has no effect.

Test parmameter can only be specified with Tx engine.

Output