4.92 chg-lg-engine

Use this command to modify an LG engine. The command class is TKLC_INTERNAL inheriting properties of DEBUG class. The Load Generator is supported on IPSG, IPLHC, IPGHC and SS7HC GPLs.

Parameters

engine (mandatory)
Range:
ayyyyyyyyy

Up to 10 alphanumeric characters; the first character must be a letter.

action (optional)

This parameter specifies the transmitting and receiving actions of a LG Engine.

Range:
snk
Rx Action: Sink Mode
ret
Rx Action: Return Mode
cap
Rx Action: Capture Mode
pbk
Tx Action: Playback mode
retl2
Rx Action: Return by L2
cong
Rx Action: Congestion.
event (optional)
Range:
ayyyyyyyyy

Up to 10 alphanumeric characters; the first character must be a letter

port (optional)
The signaling link on the card specified in the loc parameter.
Synonym:
link
Range:
a, b, a1 - a31, b1 - b31

Not all card types support all link parameter values.

See Table A-1  for valid link parameter range values for each type of card that can have a location specified in the loc parameter.

rxengine (optional)
Receiving LG Engine.
Range:
ayyyyyyyyy

Up to 10 alphanumeric characters; the first character must be a letter.

txrate (optional)

Transmission rate of a LG Engine.

Range:
0 - 10000

Example

chg-lg-engine:engine=txengine1:txrate=100

chg-lg-engine:engine=txengine1:port=b

Dependencies

The engine name specified must pre-exist in the LG Engine table.

The LG Engine table is corrupt or cannot be found.

The number of events associated with a engine should not exceed the max limit.

The txrate parameter cannot be specified with the event parameter of Rx type.

The action=pbk parameter can only be assigned to Tx event direction.

The action parameter of type snk, ret, retl2, cong, or cap can only be assigned to RX event direction.

The port specified in the command must be provisioned.

The rxengine parameter can only be specified with the action=pbk parameter.

The LG Card and Event specified in the command must belong to same network

SIF Size > 272 not supported on ss7hc

The Rx Event can not be associated to more than one Engine on the same LG card

Event dir and Action cannot be changed if engine is of Rx type and associated with the Tx engine.

The LG Event name specified in the command must exist in the table

The specified Rx engine parameter value must be associated with the card.

The port parameter cannot be specified with the event parameter of Rx type.

Engine specified in RxEngine parameter must of Rx Type.

The Rxengine specified must pre-exist in the LG Engine table.

Output