4.179 dact-lg-engine
Use this command to deactivate LG event generation/reception for a given engine on a LG engine. The command class is TKLC_INTERNAL inheriting properties of DEBUG class. The Load Generator is supported on IPSG, IPLHC, IPGHC and SS7HC GPLs.
Parameters
- loc (optional)
- The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
Example
dact-lg-engine:loc=1301
dact-lg-engine:loc=1301:dir=tx
dact-lg-engine:engine=txengine1
Dependencies
The engine name specified must pre-exist in the LG Engine table.
The loc and engine parameters cannot be specified together in the command.
The card location specified in the loc parameter must be of a provisioned LG card.
The loc parameter must be specified before the dir parameter can be specified.
Activating the state of an LG object that is already activated or deactivating the state of an LG object that is already deactivated has no effect.
Output
Related Topics