4.324 ent-loopset
Use this command to enter the loopset information into the database. This command updates the Loopset table.
Parameters
- name (mandatory)
- Loopset name. This parameter specifies an entry in the Loopset table.
The name=none parameter cannot be specified.
- pcl (mandatory)
- ANSI point code list with subfields network indicator-network cluster-network cluster member (ni-nc-ncm). The prefix subfield indicates a private point code (prefix-ni-nc-ncm). This parameter allows up to 6 comma-delimited entries in the point code list.
- Synonym:
- pcla
- Range:
- p-, 000-255
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
prefix—p-
When
chg-sid:pctype=ansi
is specified, ni = 000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni = 001-005.When
chg-sid:pctype=ansi
is specified, nc = 000 is valid if ni = 006-255.The point code 000-000-000 is not a valid point code.
- pcli (mandatory)
- ITU international point code list with subfields zone-area-id. The prefix subfield indicates a spare point code, private point code, or private and spare point code (prefix-zone-area-id). This parameter allows up to 6 comma-delimited entries in the point code list.
- pcln (mandatory)
- ITU national point code list in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc). This parameter allows up to 6 comma-delimited entries in the point code list.
- pcln24 (mandatory)
- 24-bit ITU national point code list with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp). This parameter allows up to 6 comma-delimited entries in the point code list.
Example
This example creates a new loopset using the default mode of notify .ent-loopset:name=rtp1:pcl=3-3-3,5-5-5,7-7-7,3-4-3
This example creates a new loopset and sets the mode to discard .ent-loopset:name=rtp2:mode=discard:pcl=3-3-3,5-5-5,7-7-7,3-4-3
This example creates a new loopset with four 16-bit ITU-N point codes.
ent-loopset:name=rtp1:pcln16=3-3-3,5-5-5,7-7-7,3-4-3
Dependencies
The value of the name parameter cannot already exist in the database.
The SCCP Loop Detection feature must be enabled before this command can be entered.
The GTT feature must be turned on before this command can be entered.
The Loopset table can hold a maximum of 1,000 loopset entries, with each entry containing up to 12 point codes. Additional loopset entries and point codes cannot be added when the table is full.
The Loopset table must be accessible.
The values for the pcl parameter must be unique.
The name=none parameter cannot be specified.
At least one valid point code must specified as a value for the pcl parameter.
The values for the pcl parameter cannot consist of any invalid point codes. The valid point codes must be consecutively specified and separated by commas.
Notes
There is no J7 FAK dependency on the apcln16/rpcln16/pc1n16/npc1n16/pc2n16/npc2n16 parameters. The command can be entered successfully when the J7 FAK is not enabled.
There is no J7 FAK dependency on the apcln24/rpcln24/pc1n24/npc1n24/pc2n24/npc2n24 parameters. The command can be entered successfully when the J7 FAK is enabled.
There is no J7 FAK dependency on the apcl/ apcla/rpcla/pc1a/npc1a/pc2a/npc2a parameters. The command can be entered successfully when the J7 FAK is enabled.
Output
The following example creates a new loopset and sets the mode to discard. ent-loopset:name=rtp2:mode=discard:pcl=3-3-3,5-5-5,7-7-7,3-4-3
rlghncxa03w 07-02-10 08:31:28 EST EAGLE Rel 35.6.0
LOOPSET table is (12 of 1000) 1% full
ENT-LOOPSET: MASP A – COMPLTD
;