4.324 ent-loopset

Use this command to enter the loopset information into the database. This command updates the Loopset table.

Parameters

name (mandatory)
Loopset name. This parameter specifies an entry in the Loopset table.

The name=none parameter cannot be specified.

Range:
ayyyyyyy

1 alphabetic and up to 7 alphanumeric characters

pcl (mandatory)
ANSI point code list with subfields network indicator-network cluster-network cluster member (ni-nc-ncm). The prefix subfield indicates a private point code (prefix-ni-nc-ncm). This parameter allows up to 6 comma-delimited entries in the point code list.
Synonym:
pcla
Range:
p-, 000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p-

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001-005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006-255.

The point code 000-000-000 is not a valid point code.

pcli (mandatory)
ITU international point code list with subfields zone-area-id. The prefix subfield indicates a spare point code, private point code, or private and spare point code (prefix-zone-area-id). This parameter allows up to 6 comma-delimited entries in the point code list.
Range:
s-, p-, ps-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

pcln (mandatory)
ITU national point code list in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc). This parameter allows up to 6 comma-delimited entries in the point code list.
Range:
s-, p-, ps-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-, p-, ps

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

pcln24 (mandatory)
24-bit ITU national point code list with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp). This parameter allows up to 6 comma-delimited entries in the point code list.
Range:
p-, 000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—p

msa—000–255

ssa—000–255

sp—000–255

pcln16 (mandatory)
16-bit ITU national point code with subfields unit number sub number area main number area (un-sna-mna). This parameter allows up to 6 comma-delimited entries in the point code list.
Range:
p---, 000---127
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (--).
prefix---p
un---000---127
sna---000---15
mna---000---31
mode (optional)
Mode of operation. This parameter specifies whether the message is discarded when an SCCP loop is detected.
Range:
notify
Generates a UIM without discarding the message.
discard
Generates a UIM and discards the message.
Default:
notify

Example

This example creates a new loopset using the default mode of notify .

ent-loopset:name=rtp1:pcl=3-3-3,5-5-5,7-7-7,3-4-3

This example creates a new loopset and sets the mode to discard .

ent-loopset:name=rtp2:mode=discard:pcl=3-3-3,5-5-5,7-7-7,3-4-3

This example creates a new loopset with four 16-bit ITU-N point codes.

ent-loopset:name=rtp1:pcln16=3-3-3,5-5-5,7-7-7,3-4-3

Dependencies

The value of the name parameter cannot already exist in the database.

The SCCP Loop Detection feature must be enabled before this command can be entered.

The GTT feature must be turned on before this command can be entered.

The Loopset table can hold a maximum of 1,000 loopset entries, with each entry containing up to 12 point codes. Additional loopset entries and point codes cannot be added when the table is full.

The Loopset table must be accessible.

The values for the  pcl parameter must be unique.

The name=none parameter cannot be specified.

At least one valid point code must specified as a value for the pcl parameter.

The values for the pcl parameter cannot consist of any invalid point codes. The valid point codes must be consecutively specified and separated by commas.

Notes

There is no J7 FAK dependency on the apcln16/rpcln16/pc1n16/npc1n16/pc2n16/npc2n16 parameters. The command can be entered successfully when the J7 FAK is not enabled.

There is no J7 FAK dependency on the apcln24/rpcln24/pc1n24/npc1n24/pc2n24/npc2n24 parameters. The command can be entered successfully when the J7 FAK is enabled.

There is no J7 FAK dependency on the apcl/ apcla/rpcla/pc1a/npc1a/pc2a/npc2a parameters. The command can be entered successfully when the J7 FAK is enabled.

Output

The following example creates a new loopset and sets the mode to discard. ent-loopset:name=rtp2:mode=discard:pcl=3-3-3,5-5-5,7-7-7,3-4-3

    rlghncxa03w 07-02-10 08:31:28 EST  EAGLE Rel 35.6.0
    LOOPSET table is (12 of 1000) 1% full 
    ENT-LOOPSET: MASP A – COMPLTD 
;