4.332 ent-pct

Use this command to enter Point Code and CIC Translations.

Parameters

epc (mandatory)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm). 
Synonym:
epca
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

epci (mandatory)
ITU international destination point code with subfields zone-area-id.
Range:
0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

zone—0–7

area—000–255

id—0-7

The point code 0-000-0 is not a valid point code.

epcn (mandatory)

ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).

Range:
0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

realpc (mandatory)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
realpca
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

realpci (mandatory)
ITU international destination point code with subfields zone-area-id.
Range:
0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

zone—0–7

area—000–255

id—0-7

The point code 0-000-0 is not a valid point code.

realpcn (mandatory)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
Range:
0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

ecice (optional)
The end of the Emulated Circuit Identification Code range.
Range:
0-4095
ITU TUP/ISUP
0-16383
ANSI ISUP
0-4294967295
ANSI Q.BICC
*
Default:
*
ecics (optional)
The start of the Emulated Circuit Identification Code range.
Range:
0-4095
ITU TUP/ISUP
0-16383
ANSI ISUP
0-4294967295
ANSI Q.BICC
*
Default:
*
filtpc (optional)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm). 
Synonym:
filtpca
Range:
0-255, *

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

The asterisk (*) value is not valid for the ni subfield.

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001-005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006-255.

When chg-sid:pctype=ansi is specified, ni-*-* is valid if ni = 006-255.

The point code 000-000-000 is not a valid point code.

filtpci (optional)
ITU international destination point code with subfields zone-area-id.
Range:
0-255, *

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

zone—0-7

area—000-255

id—0-7

The point code 0-000-0 is not a valid point code.

filtpcn (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
Range:
0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

rcice (optional)
The end of the Real Circuit Identification Code range.
Range:
0-4095
ITU TUP/ISUP
0-16383
ANSI ISUP
0-4294967295
ANSI Q.BICC
*
Default:
*
rcics (optional)
The start of the Real Circuit Identification Code range.
Range:
0-4095
ITU TUP/ISUP
0-16383
ANSI ISUP
0-4294967295
ANSI Q.BICC
*
Default:
*
relcause (optional)
Release Cause
Range:
0 - 127
Default:
0
si (optional)
Service Indicator
Range:
0
NM
3
SCCP
5
ISUP
4
TUP
13
ANSI Q. BICC
*
Default:
*
ssn (optional)
SCCP Subsystem number
Range:
0 - 255
Default:
*

Example

ent-pct:epc=1-1-1:realpc=2-2-2:si=5:ecics=100:ecice=200

ent-pct:epc=1-1-2:realpc=2-2-3:si=3:ssn=10:filtpc=5-5-5

Dependencies

If the ecice or rcice parameter is specified, then the ecics or rcics parameter must be specified, respectively.

The value specified for the ecice/rcice parameter must be equal to or greater than the value specified for the ecics/rcics parameter, respectively.

Full point codes must be specified as the values for the realpc/realpca/realpci/realpcn  and epc/epca/epci/epcn parameters.

The PCT table is corrupt or cannot be found.

The PCT table cannot contain more entries than the amount specified by the FAK for the PCT quantity feature.

The si=3 parameter must be specified before the ssn parameter can be specified.

The values specified for the  realpc/realpca/realpci/realpcn  and filtpc/filtpca/filtpci/filtpcn  parameters must already exist in the Route table.

The Route table is corrupt or cannot be found.

The values specified for the  epc/epca/epci/epcn, filtpc/filtpca/filtpci/filtpcn, and realpc/realpca/realpci/realpcn parameters must have the same domain.

A PCT quantity feature must be enabled before this command can be specified.

If the ssn or ecics parameter is specified, then the si parameter must be specified.

Duplicate values for the following Key combinations are not allowed: 

  • epc/epca/epci/epcn + filtpc/filtpca/filtpci/filtpcn  + si + ssn/(ecics/ecice)
  • realpc/realpca/realpci/realpcn  + filtpc/filtpca/filtpci/filtpcn + si + ssn/(rcics/rcice)

The values specified for the realpc/realpca/realpci/realpcn and filtpc/filtpca/filtpci/filtpcn  parameters must have at least one route for each value defined in the Route table.

If the ITUDUPPC feature is turned on, and ITU-N Point codes are specified, then the values specified for the epcn, realpcn, and  filtpcn parameters must have the same group code.

A total of 250 unique epc and  rpc values are supported in the PCT table.

A total of 100 PCT Translations with a single epc and realpc  value are supported in the PCT table.

A spare point code cannot be specified as a value for the epci/epcn, filtpci/filtpcn, and realpci/realpcn parameters.

The ecics parameter must be specified before the relcause parameter can be specified.

A value of 4, 5, or 13 must be specified for the si parameter before the ecice/ecics and rcice/rcics parameters can be specified.

If the rcics parameter is specified, then the ecics parameter must be specified.

If the ecics, ecice, and rcics parameters are specified, then the rcice parameter must be specified.

The values specified for the epc/epca/epci/epcn, filtpc/filtpca/filtpci/filtpcn, and realpc/realpca/realpci/realpcn parameters cannot be the same as the STP point code.

The values specified for the epc/epca/epci/epcn, filtpc/filtpca/filtpci/filtpcn, and realpc/realpca/realpci/realpcn parameters cannot be the same as the STP capability point code.

The value specified for the ecics/ecice and rcics/rcice parameters must be within the range specified by the parameter definition.

The difference between the values specified for the ecice and  ecics parameters must be equal to the difference between the values specified for the rcice and  rcics parameters.

A value of 5 or 13 must be specified for the si parameter before the relcause parameters can be specified.

The ssn and cic parameters cannot be specified together in the command.

If the ecics, rcics, and rcice parameters are specified, then the ecice parameter must be specified.

If the same value is specified for the epc  and realpc parameters, then the values specified for the ecics/ecice and rcics/rcice parameters cannot indicate the same range.

Only one of the filtpc/filtpca/filtpci/filtpcn parameters can be specified in the command.

The value specified for the epc/epci/epcn parameter cannot be the same as a secondary point code.

Output

ent-pct:epc=1-1-1:realpc=5-5-5:si=13:ecics=10:ecice=20:relcause=15

    tekelecstp 10-08-10 18:29:41 EST  EAGLE 43.0.0
    ent-pct:epc=1-1-1:realpc=5-5-5:si=13:ecice=10:ecics=20:relcause=15
    Command entered at terminal #4.
    ENT-PCT: MASP A - COMPLTD 
;

Related Topics