4.547 rtrv-pct
Use this command to display Point Code and CIC Translations.
Parameters
- epc (optional)
- ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
- Synonym:
- epca
- Range:
- 000-255
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
When
chg-sid:pctype=ansi
is specified, ni = 000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni = 001–005.When
chg-sid:pctype=ansi
is specified, nc = 000 is valid if ni = 006–255.The point code 000-000-000 is not a valid point code.
- epcn (optional)
-
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
- filtpc (optional)
- ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
- Synonym:
- filtpca
- Range:
- 0-255, *
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
The asterisk (*) value is not valid for the ni subfield.
When
chg-sid:pctype=ansi
is specified, ni=000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni=001–005.When
chg-sid:pctype=ansi
is specified, nc=000 is valid if ni=006–255.When
chg-sid:pctype=ansi
is specified, ni-*-* is valid if ni =006–255.The point code 000-000-000 is not a valid point code.
- filtpcn (optional)
- ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
- realpc (optional)
- ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
- Range:
- 000-255
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).
When
chg-sid:pctype=ansi
is specified, ni = 000 is not valid.When
chg-sid:pctype=ansi
is specified, nc = 000 is not valid if ni = 001–005.When
chg-sid:pctype=ansi
is specified, nc = 000 is valid if ni = 006–255.The point code 000-000-000 is not a valid point code.
- Range:
- realpcn (optional)
- ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the
chg-stpopts:npcfmti
flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
Example
rtrv-pct:epc=1-1-1
rtrv-pct:realpc=2-2-2
Dependencies
If the ssn or ecics parameter is specified, then the si parameter must be specified.
A full point code must be specified as the value for the realpc/realpca/realpci/realpcn and epc/epca/epci/epcn parameters.
The value specified for the ecice/rcice parameter must be equal to or greater than the value specified for the ecics/rcics parameter, respectively.
The values specified for the epc/epca/epci/epcn, filtpc/filtpca/filtpci/filtpcn, and realpc/realpca/realpci/realpcn parameters must have the same domain.
The PCT table is corrupt or cannot be found.
The values specified for the realpc/realpca/realpci/realpcn and filtpc/filtpca/filtpci/filtpcn parameters must have at least one route for each value defined in the Route table.
If a groupcode is specified then the values specified for the realpc, filtpc, and epc parameters must have the same group code.
A spare point code cannot be specified as a value for the epci/epcn, filtpci/filtpcn, and realpci/realpcn parameters.
The ecics or rcics parameter must be specified before the relcause parameter can be specified.
The si=3 parameter must be specified before the ssn parameter can be specified.
If the ecice or rcice parameter is specified, then the ecics or rcics parameter must be specified, respectively.
If the ecics, ecice, and rcics parameters are specified, then the rcice parameter must be specified.
A value of 4, 5, or 13 must be specified for the si parameter before the ecice/ecics and rcice/rcics parameters can be specified.
The values specified for the epc/epca/epci/epcn, filtpc/filtpca/filtpci/filtpcn, and realpc/realpca/realpci/realpcn parameters cannot be same as the STP point code.
The values specified for the epc/epca/epci/epcn, filtpc/filtpca/filtpci/filtpcn, and realpc/realpca/realpci/realpcn parameters cannot be same as the STP capability point code.
The epc/epca/epci/epcn or realpc/realpca/realpci/realpcn parameter must be specified if any other optional parameter is specified.
The values specified for the ecics/ecice and rcics/rcice parameters must be within the range specified by the parameter definition.
The difference between the values specified for the ecice and ecics parameters must be equal to the difference between the values specified for the rcice and rcics parameters.
A value of 5 or 13 must be specified for the si parameter before the relcause parameters can be specified.
The values specified for the realpc/realpca/realpci/realpcn and filtpc/filtpca/filtpci/filtpcn parameters must already exist in the Route table.
The ssn and cic parameters cannot be specified together in the command.
If the ecics, rcics, and rcice parameters are specified, then the ecice parameter must be specified.
If the same value is specified for the epc and realpc parameters, then the values specified for the ecics/ecice and rcics/rcice parameters cannot indicate the same range.
Only one of the filtpc/filtpca/filtpci/filtpcn parameters can be specified in the command.
The value specified for the epc/epci/epcn parameter cannot be the same as a secondary point code.
Output
rtrv-pct
tekelecstp 10-08-26 11:31:14 EST EAGLE 43.0.0
EPCA FILTPCA REALPCA SI SSN RELCAUSE
001-001-001 * 002-002-002 4 --- 10
ECICS = 10 ECICE = 20
RCICS = 30 RCICE = 40
EPCI FILTPCI REALPCI SI SSN RELCAUSE
1-001-2 2-002-2 2-002-2 3 10 ---
ECICS = ---------- ECICE = ----------
RCICS = ---------- RCICE = ----------
EPCN FILTPCN REALPCN SI SSN RELCAUSE
00300 * 00200 * --- ---
ECICS = ---------- ECICE = ----------
RCICS = ---------- RCICE = ----------
Unique EPC is 3 of 250
Unique RealPC is 3 of 250
PCT table is (3 of 1000) 1% full.
;