4.349 ent-shlf

Use this command to add an equipment shelf to the database.

Parameters

loc (mandatory)
The location of the shelf.
Range:
1200, 1300, 2100, 2200, 2300, 3100, 3200, 3300, 4100, 4200, 4300, 5100, 5200, 5300, 6100, 6200, 6300
type (mandatory)
The type of equipment shelf to be configured.
Range
ext, fpb
fan (optional)
This parameter turns ON/OFF the FAN option. If it is turned ON, the FAN power for this shelf will be added to the Frame Power Budget.
Range
off,
on

Example

ent-shlf:type=ext:loc=1200

ent-shlf:type=imtswch:loc=6100

ent-shlf:type=fpb:loc=6200:fan=on

Dependencies

The frame and shelf values of the shelf location parameter (loc) must be within the valid range (xyzz, where x=frame and y=shelf; zz is always 00 for this command).

The specified shelf location must not have been configured previously.

The Shelf table is corrupt or cannot be found by the system.

A shelf cannot be provisioned at location 1100. This location is reserved for the control shelf.

The shelf locations 6200 and 6300 are reserved for shelf type FPB only. However, shelf with type=fpb can be provisioned in any shelf location from 1200 to 6300.

Notes

None

Output

ent-shlf:type=ext:loc=1200

    rlghncxa03w 04-01-07 11:11:28 EST  EAGLE 31.3.0
    ENT-SHLF: MASP A - COMPLTD 
;
ent-shlf:type=fpb:loc=6300:fan=on

tekelecstp 03-09-12 11:11:28 EST EAGLE 45.0.0
ENT-SHLF: MASP A - COMPLTD
;