4.439 rept-stat-tstslk

Use this command to generate a report of the status of the MTP signaling links currently under test.

Parameters

link (optional)
SS7 signaling links. The SS7 signaling link that is being tested.
Synonym:
port
Range:
a, b, a1 - a3, b1 - b31

Not all card types support all link parameter values.

See Table A-1  for valid link parameter range values for each type of card that can have assigned signaling links.

loc (optional)
The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
loopback (optional)
Loopback test type.
Range:
sltc
lxvr
oam
line
payload

Example

rept-stat-tstslk

rept-stat-tstslk:loc=1201

rept-stat-tstslk:loc=1203:link=a

rept-stat-tstslk:loopback=lxvr

Dependencies

The card location specified in the loc parameter must be equipped.

The signaling link specified in the link parameter must be equipped.

If the link parameter is specified, the loc parameter must be specified.

The signaling link specified in the link parameter must be an SS7 signaling link.

This command cannot be entered for E5-ENET-B cards that are running the IPGHC or IPSG application, or that have IPGHC or IPSG-M3UA links.

The card location specified in the loc parameter cannot be reserved by the system.

This command cannot be entered during upgrade.

Notes

None

Output

If no parameters are specified, all links in test are displayed.

If only the loc parameter is specified, all links in test on the specified card are displayed.

If the loc and link parameters are specified, the specified link on the specified card is displayed.

If the loopback parameter is specified, all links in the specified type of loopback test are displayed.

rept-stat-tstslk

    tekelecstp 04-01-07 10:05:28 EST  EAGLE 31.3.0
    SLK        LOOPBACK   MAX-TIME   TEST-TIME  
    1102,A1     SLTC      01:00:00   00:04:01   
    1201,A      OAM       02:00:00   01:04:11   
    1203,A      LXVR      00:50:00   00:22:21   
    1203,B      LXVR      24:00:00   20:04:01   
    1208,A      PAYLOAD   01:10:00   01:05:22   
    1211,A      LINE      21:30:00   00:14:01   
;

Legend

  • SLK—Card and signaling link that are being tested.
  • LOOPBACK—Type of loopback test being run.
  • MAX-TIME—Maximum length of time for the test to run, as specified in the tst-slk command time parameter.
  • TEST-TIME—The length of time that the test has been running when this command was entered.