Customer Known Bug List
The following table lists the known bugs and the associated Customer Impact Statements.
Table 8-2 EAGLE Release 48.0 Customer Known Bugs (December 2025)
| Bug Number | SR | Severity | Title | Customer Impact |
|---|---|---|---|---|
| 38709413 | Y | 2 | Packet Count Not Displayed for All Associations | No loss of Traffic and configured associations for the Eagle card may not be displayed in output of REPT-STAT-MON command. |
| 28185911 | N | 3 | LIM/SCCP card(s) denied SFAPP alm with new SFR MFC servc needs clarification | Operator needs to run the rept-stat-mfc commands for SFAPP and SFR services or look at the measurements to determine the service that is causing the alarm.
|
| 28253971 | N | 3 | Rel.46.7_DB_Exp:Sev1 rmtp_utl.c with lines 349 and 384 obsrvd during upgrade | These severity 1 troubles may appear at end of the full DB download after a cold restart of a SCCP64 card. There is no known impact. |
| 29197515 | N | 3 | R46.5.1.10_FT: UAM 115 & 116 and UIM 118 & 119 are not getting generated with tpsalmtype=maxslktps for SLIC card | TPS alarms do not show when the card running the IPSG is a SLIC and traffic crosses its threshold value when tpsalmtype is set to MAXSLKTPS. TPS alarms are generated correctly when tpsalmtype is set to RSVDSLKTPS. |
| 29378816 | N | 3 | R46.6.3: LINK LED for ports B & C are not working correctly if UDP\TCP connection is not configured for SIP\ENUM | The LINK LEDs on ports B & C are illuminated green even when no UDP/TCP connections are provisioned for either port. |
| 29378828 | N | 3 | R46.6.3: LINK LED for PORT D is not working correctly for SLIC DEIR card | The colors of the LED (green/red) for the SLIC card, port D, when running the DEIR application are reversed from what they should be: red when it should be green, and green when it should be red. |
| 29539191 | N | 3 | IDPR_Enh:Module mdb_srvs.c Line 369 observed on LIM card while executing ent-srvsel command with ANSI domain | When SRVSEL entries of type ANSI and ITUN24 are configured with the same values of GTI, TT, NP, NAI, and SSN, cards may observe UAM 0034 "Card database is inconsistent" and report "Module mdb_srvs.c" severity 1 trouble. |
| 29873349 | N | 3 | copy-disk command failed to copy files from active to standby causing sev 1 dmshc_utl.c Line 1240 DMS Error
|
The copy-disk command may fail to transfer files as expected. Workaround: Retry the operations and the copy eventually succeeds at the second or third attempt.
|
| 30431027 | N | 3 | R46.7:During upgrade multiple LIM cards did not return to IS-NR in less than 8 minutes | LIM cards will take a little longer than 8 minutes to return to IS-NR. |
| 31098175 | N | 3 | The FTP command with -a option is broken | FTP with the -a option does not work. There is no impact on traffic. Workaround: Run two commands instead: Use FTP without the -a option, then use the copy-tbl command.
|
| 31647295 | N | 3 | R46.9_ST: Observing Module mfctmutl.c Line 1334 Class 01c3 Severity 1 on IPSG cards | A few ATI ack messages do not reach the SFAPP card when the card is congested under maximum load. The corresponding UC #1, #2, and #3 messages will not be applied, but the original message will still be processed. |
| 31948123 | N | 3 | R46.5.1.20_4PORT: Traffic is getting dropped without congestion on M2PA/M3UA link | If a 2 or 4 port IPSG card with 4 or fewer links configured has traffic above the card capacity (if allowed by sum of MAXSLKTPS of all links on the card which exceeds card capacity), the card may silently discard the excess traffic above the card capacity of 12K TPS without any congestion alarm. Workaround: Sum of MAXSLKTPS of all links on a 4-port IPSG card should not exceed 12K TPS. Configure MAXSLKTPS same as RSVDSLKTPS whenever there is no specific reason for configuring MAXSLKTPS higher than RSVDSLKTPS. |
| 31959811 | N | 3 | R46.5.1.20_4PORT: Dynamic DB goes into inconsistent state after congestion is cleared on 4 Port | The DDB Inconsistent alarm will be observed when links get congested followed by the route failure to a non-adjacent node. There is no traffic impact and DDB alarm will be cleared in the next DDB audit. Workaround: The aud-data:type=ddb command can be executed if the alarm needs to be cleared immediately due to this particular issue. |
| 32001102 | N | 3 | Rel.46.5.1.20_FT:upg_drms.c and mdb_mtls.c severity 1 observed while performing major upgrade from eagle release 46.5.1.10.0-70.51.0 to 46.5.1.20.0-77.2.0 | No traffic impact. |
| 32028844 | N | 3 | Rel.46.5.1.20_FT:OA&M IP Security feature risk alarm not observed after major upgrade from eagle release 46.5.1.10.0-70.51.0 to 46.5.1.20.0-77.2.0 | No traffic impact. |
| 32056273 | N | 3 | Rel.46.5.1.20_FT:DB-DIFF observed on newly provisioned SFAPP card in LEARN/TEST mode | No traffic impact. There are two workarounds: 1. Execute the "rtrv-vlr-prof" or rtrv-vlr-roaming" command after the sync before executing the commands to configure a new SFAPP card. 2. If the new SFAPP card reports DB-DIFF then re-initialize the SFAPP card. Re-initialization will be resolve the DB-DIFF.
|
| 32180217 | N | 3 | R46.5.1.20_4PORT:Severity 1 "radbvdcm.c" is observed on 4 Port SLIC IPSG | No traffic impact. |
| 32599847 | N | 3 | Rel.46.9.1_ST:INIT-SYS causes DDB INCONSISTENT issue on IPSG/E1T1 card | INIT-SYS in not a normal operational command and is only used in emergency situations. Normally a customer would not attempt to initialize cards by application type. No impact unless cards could not be initialized and DDB normalized for each individual card if customer executed init-sys. |
| 32622846 | N | 3 | Rel46.9.1_ST: ATM links are taking around 20 mins to come IS-NR after initialization | There is no impact, just a delay, but the links come up in service. However, this could impact future software upgrades if customer has a large quantity of ATM cards/links. The upgrade may not complete during a standard maintenance window. |
| 32622893 | N | 3 | Rel.46.9.1_ST:Obit "Module restart.c Line 1590" observed on E1T1 card while inh/alw IMT bus | No Operational Impact on Eagle STP. |
| 34528313 | N | 3 | R47.0_ST: Observed severity 1, slog_utl.c Line 644 Class 01c7 during incremental upgrade phase 3 | No impact to customer traffic. |
| 36239284 | N | 3 | R47.0.0.2_GL:Eagle sending SHUTDOWN-COMPLETE when SHUTDOWN-ACK message is received in Established state | Could cause loss of traffic as association is aborted or reset by peer node. |
| 36615603 | Y | 3 | MASP Disk read failure observed while taking Backup on External Server | No impact on traffic and corrective measures implemented following published KM documents. |
| 37076262 | N | 3 | copy-disk fails with module tco_oamhc.c - error writing table 641 on standby TDM | Post upgrade to R48.0 the file size of BLDC32 has increased from 10MB to 11MB, when the copy-disk command is executed it fails with a table size mismatch. Workaround: Standby OAM needs to be repaired with the command below. > chg-db:action=repair |
| 38519340 | N | 3 | Rel.48.0_ERTC69:Thermal T2 event on STC card causes IPSG links to flap and eroute sockets to go inactive | When card temperature increases from normal T1 level then to T2 level the STC card stops monitoring, which is correct behavior. However, when the temperature on STC card returned to normal/T1 level the STC monitoring did not resume. Therefore, particular STC card won’t process the traffic due to the service is inactive on the card. Workaround: Once the temperature is normal, just reboot/restart the card. |
| 38608264 | N | 3 | R48.0_ST: Observed OBIT restart.c from Line 1597 Class 0001 on e1t1 SLIC card at 1205 | upgrade phase3 | Incremental software upgrade script may fail and cards might have to be manually flashed or upgrade script re-started to complete upgrade. |
| 38608634 | N | 3 | R48.0_ST: Observed DMS Error" for table 617 (BLDC64) | Upgrade Error: Timeout occurred waiting on cards to boot| OBIT Module restart.c from Line 1597 Class 0001 on IPSG69 SLIC | Severity 1 Module fst_mgr.c| Severity 1 Module mfctmutl.c | Incremental software upgrade script may fail and cards might have to be manually flashed or upgrade script re-started to complete upgrade. |
| 38632541 | Y | 3 | Queries regarding 0911 - Dynamic database is inconsistent | Affected card missed some DDB updates and workaround is to manually do a DDB audit to update card to clear condition. |
| 38633189 | Y | 3 | R48.0_ST: Observing slicimt_irx line 261,tk_fpga_imt_ Line 1896 & 1922 and obit Module itx_seq_msg. Line 370 Class 0065 while incremental upgrade from 80.27.0 to 80.28.0 | No customer impact as the card is being flashed as part of the upgrade process. |
| 38650883 | N | 3 | Rel_48.0:Severity 1 gws_shr.c Line 696 Class 0202 observed after initializing OAM post-upgrade | There is no impact to customer. |
| 38654915 | Y | 3 | Time zone getting changed after MASP switchover during the upgrade of rel 47.1 | No impact as workaround is to manually correct timezone via user command. |
| 38657098 | Y | 3 | After upgrade to release 47.1.0.2.0-79.38.0 there is one SLIC E1 link that will not restore | On release 47.1.0.2 some SLIC E1 card links may not restore after the upgrade due to the SLIC HW FISU generation. |
| 38669570 | N | 3 | R48.0_defensics: OBITs | |ath_vxw_mgr. on IPSM card | IPSM card may boot while executing Defensics scan. No impact as Defensics scans are not normal daily tasks. |
| 29408928 | N | 4 | R46.6.3_FT: Incorrect Eagle version is shown in UNIX and LINUX FTRA GUI when CSV files are created and FTRA is completed | FTRA may display incorrect EAGLE release version on the GUI when providing information about generated CSV files upon completion. However, the version mentioned inside the generated CSV files is correct. |
| 30212669 | N | 4 | Observed pmtc_mgr.c Line 942 during Phase 3 of upgrade | Software upgrade process - Observed pmtc_mgr.c Line 942 during Phase 3 of upgrade. |
| 30914993 | N | 4 | DRMS Init duration has doubled | The time to initialize DRMS has increased by 3 minutes, which means that an OAM will take 3 more minutes to come IS-NR, or go to duplex mode. |
| 31646563 | N | 4 | R46.9_ST: oamhc_init.c Severity 1 with lines 3018 and 3021 is being observed on active OAM | There is no loss of service. Debug output will not be available. |
| 33629173 | N | 4 | R46.9.4_ST: observed OBIT Module ath_vxw_mgr. during flashing of E1T1/ATM EPMB card and Sev1 fst_mgr.c Line 3351 on Active E5OAM during phase 3 | No impact to the system, upgrade completed successfully and the cards reporting the OBIT came back into service with no impacts seen to the card functionality and no traffic impact was seen either. |
| 38167555 | N | 4 | R46.9.4_ST: observed OBIT Module ath_vxw_mgr. during flashing of E1T1/ATM EPMB card and Sev1 fst_mgr.c Line 3351 on Active E5OAM during phase 3 | No impact to the system, upgrade completed successfully and the cards reporting the OBIT came back into service with no impacts seen to the card functionality and no traffic impact was seen either. |
| 38167555 | N | 4 | IMT failure during NEBs altitude testing | If this condition occurs in a customer environment and physical re-seat of IMT bus cards are required, then this could cause congestion and loss of traffic. |
| 38554324 | N | 4 | R48.0_E1T1: Inconsistent behavior of SLICV3 card while changing CRC4 parameter | The E1/T1 card must be rebooted to implement a new CRC4 parameter change which would impact assigned links on the card during reboot. In normal operations, these parameters are typically not changed after initial setup. |
| 38592805 | N | 4 | ent-serial-num should accept serial numbers in the format YYWWMMXXXX | The correct serial number would not be able to be entered into the system and locked. |
| 38606486 | N | 4 | R48.0_ST: Upgrade did not retry activating blsl932 FLASH (seems print is missing) on failing in PHASE 3 | Incremental software upgrade script may fail and cards might have to be manually flashed or upgrade script re-started to complete upgrade. |
| 38607043 | N | 4 | R48.0_ST: observed imtc_mgr.c Severity 1 from Line 5996 Class 01c3 , and from Line 6035 Class 01d0 on active E5OAM | Incremental software upgrade script may fail and cards might have to be manually flashed and upgrade script re-started to complete upgrade. |