E100 as an NCN
R7.0 GA now supports deployment of the E100 Oracle Talari Appliance as a primary and secondary NCN for up to 8 Client sites (9 total sites per-network). This is done in the Configuration Editor from the Advanced tab under Sites > [Site Name] > Basic Settings where the Model should be the E100 and the Mode can now be either primary NCN or secondary NCN.
After completing the configuration, the user will Export it to Change Management and follow the prompts to create a package for the E100 appliance. Once you have uploaded the package to the E100, the Home Page will reflect that the E100 is functioning as the NCN Appliance.
Note: If you try to push a configuration through Change Management where the primary or secondary NCN is an E100 and you have defined more than 8 Client sites (resulting in more than 9 total sites per-network), the configuration will not pass the Validation Check.
Capacity Report for the E100 NCN
Appliance Model |
T510 |
T730 |
T750 |
T860 |
E100 |
T3010 |
T5000 |
T5200 |
Supported as NCN |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Max Client Sites as NCN |
N/A |
N/A |
32 |
32 |
8 |
128 |
256 |
550 |
Max Static Conduits |
8 |
16 |
32 |
32 |
32 |
128 |
256 |
550 |
Max Dynamic Conduits |
4 |
8 |
16 |
16 |
16 |
32 |
32 |
32 |
Max WAN Ingress Paths |
36 |
72 |
216 |
216 |
216 |
576 |
1152 |
5500 |
Max WAN Egress Paths |
36 |
72 |
216 |
216 |
216 |
576 |
1152 |
5500 |
Max Flows (TCP Term off) |
64,000 |
64,000 |
64,000 |
64,000 |
64,000 |
256,000 |
512,000 |
512,000 |
Max Flows (TCP term on) |
500 |
4,000 |
8,000 |
8,000 |
8,000 |
16,000 |
16,000 |
16,000 |
Max Public WAN Links |
3 |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
Max Private WAN Links |
32 |
32 |
32 |
32 |
32 |
32 |
32 |
32 |
Max Routes (Static & Dynamic) |
16,000 |
16,000 |
16,000 |
16,000 |
16,000 |
16,000 |
16,000 |
16,000 |
Max Recommended Routing DomainsFoot 1 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
16 |
Footnote 1
NetFlow (Support for Version 9 and IPFIX)
While NetFlow v5 is the default setting, users now have the ability to export flow information using NetFlow v9 and IPFIX. To enable NetFlow and select the version, navigate to Integrate > NetFlow Host Settings from the web UI of any Talari Appliance, click the Enable NetFlow button, then select the preferred version from the NetFlow Version drop down.
Note:
To complete the configuration, you must enter in a NetFlow Host IP Address and Port number, then click the Apply Settings button.Additional Features in 7.0 GA
Additional features included in 7.0 GA include support for the VT800 at the data rate of 500Mbps through a Conduit on the Azure cloud and the VT800 at the data rate of 2Gbps for ESXi on the Intel Xeon E7-8870v4.
Appliance Model |
Throughput 1400B at MOS score of 4.3 or Better |
T510 |
2 x 40 Mbps |
T730 |
2 x 80 Mbps |
T750 |
2 x 120 Mbps |
E100 |
2 x 200 Mbps |
T860 |
2 x 800 Mbps |
T3010 |
2 x1 Gbps |
T5000 |
2 x 3 Gbps |
T5200 |
2 x 5 Gbps |
VT800 (ESXi) |
2 x 2 Gbps |
VT800 (Azure) |
2 x 500 Mbps |
VT800 (Hyper-V) |
2 x 200 Mbps |
CT800 |