Alarm Generation and Monitoring

The products generate alarms when certain hardware and software events occur. For more information about OCSBC alarms for RADIUS, refer to the Maintenance and Troubleshooting Guide.

The RADIUS ACCOUNTING CONNECTION DOWN alarm, detailed in the table below, is directly associated with the OCSBC’s RADIUS functionality. When enabled connections to RADIUS servers have timed-out without a response from the RADIUS server, the alarm is activated. The RADIUS ACCOUNTING CONNECTION DOWN alarm triggers a Simple Network Management Protocol (SNMP) trap that is sent via the syslog Management Information Base (MIB) (ap-syslog.mib). For a list of all SNMP-related alarms and their associated traps, refer to the table of SNMP trap correlation to OCSBC’s alarms in Oracle’s MIB Reference Guide.

This alarm has no impact on a the health score of a OCSBC that is part of an HA Node.

RADIUS Alarms

The table below describes the OCSBC’s alarms for RADIUS.

Alarm Alarm ID Alarm Severity Cause Log Message Actions
RADIUS ACCOUNTING CONNECTION DOWN 327681 CRITICAL if all enabled and configured RADIUS accounting server connections have timed-out without a response from the RADIUS server.

MAJOR if some, but not all configured RADIUS accounting server connections have timed-out without a response from the RADIUS server.

The enabled connections to RADIUS servers have timed-out without a response from the RADIUS server. CRITICAL: All enabled accounting connections have been lost. Check accounting status for more details.

MAJOR: One or more enabled accounting connections have been lost. Check accounting status for more details.

apSyslogMessageGenerated trap generated

critical, major dry contact

syslog