Manage Fault Notification on the Northbound Interface

Synchronize Alarms for a Northbound Fault Trap Receiver

A specified time period can be configured to synchronize northbound interface alarm fault trap notifications from devices that are managed by OCSDM to determine the health of devices.

When the alarm synchronization feature is configured for a specified time interval and enabled, traps are resent from devices to the northbound interface. The system administrator determines which traps are new and which are duplicates. A system administrator uses this feature to ensure that device alarm fault trap notifications received on their northbound systems are current with the alarm trap notification generated by the device or in situations when previous traps are lost on OCSDM or the northbound system and need to be regained from the device.

Note:

The Start time fields default to 24 hours prior to the current time and the End time fields default to the current time.

  1. From the menu bar, select Settings, Faults, Trap receivers.
  2. In the Trap receivers configuration table, select a trap receiver and click Sync.
  3. In the Trap receiver alarm synchronization dialog box, complete the following fields:
  4. Click OK.
  5. In the confirmation dialog box, a message displays indicating the total number of events or alarms to be synchronized based on the parameters that you configured in this task. Click Yes to synchronize them.

Edit a Northbound Fault Trap Receiver

  1. From the menu bar, select Settings, Faults, Trap receivers.
  2. In the Trap receivers configuration table, click Edit.
  3. In the Edit trap receiver dialog box, you can edit the following fields for the Destination configuration:
  4. Edit the following fields for the Filter configuration:
  5. You can edit the following options to specify the destination of traps:
    • Select the All devices radio button to send traps from all devices to Northbound Trap Receiver. This means that traps from all devices are sent to the Northbound trap receiver.
    • Select the Select devices radio button to forward traps from the selected device to the Northbound trap receiver. If you select this option, proceed to the next steps.
  6. If you need to add a device to the Mangaged devices table, expand the hierarchical group folder and navigate to the network function (NF) device you want as a trap source.
  7. Select the device and click Add.
    The NF device appears in the Selected trap source devices table.
  8. Repeat the previous two steps to add more devices.
  9. If you need to remove a device to the Selected trap source devices table, expand the hierarchical group folder and navigate to the network function (NF) device you want as a trap source.
  10. Select the device and click Remove.
    The NF device appears in the Mangaged devices table.
  11. Repeat the previous two steps to remove more devices.
  12. Click OK.
    The trap receiver appears in the Trap receivers configuration table. You can add a maximum of 10 trap receivers to the Trap Receivers Configuration table.

View Northbound Fault Trap Receivers

  1. From the menu bar, select Settings, Faults, Trap receivers.
  2. In the Trap receivers configuration table, view the following trap receiver column information:

Delete a Northbound Fault Trap Receiver

  1. From the menu bar, select Settings, Faults, Trap receivers.
  2. In the Trap receivers configuration table, select a network function (NF) device trap receiver and click Delete.
  3. In the Success dialog box, click OK.