You must create an upload staging record for each meter that was read. The name of this table is CI_​MR_​STAGE_​UP. The following table describes each column on this table.

Column Name

Length

Req'd

Data Type

Comments

MR_​STAGE_​UP_​ID

12

Y

A/N

This is the unique identifier of the meter read upload staging record. This key is a sequential number so you can use a database function to assign the value when populating the table.

BADGE_​NBR

30

N

A/N

If specified, this must correspond with a badge number on one of your meters. See the MTR_​CONFIG_​ID note below for how this field can be used. Also see the note under MTR_​ID_​NBR if you plan to use the meter's alternate ID's rather than the badge number to identify the meter being read.

MTR_​CONFIG_​ID

10

See note

A/N

This must correspond with a meter configuration number on one of your meters. You may leave this column blank if BADGE_​NBR or MTR_​ID_​TYPE_​CD / MTR_​ID_​NBR is populated.

READ_​DTTM

15

Y

DateTime

The date and time of the meter read.

MR_​UP_​STATUS_​FLG

2

Y

A/N

This must be set to P for Pending.

MR_​ID

12

N

N

Leave this column blank. It will be assigned by the system when it creates a meter read record.

MR_​SOURCE_​CD

12

N

A/N

The source of the meter read.

GEO_​TYPE_​CD

8

N

A/N

See the description of the GEO_​VAL field.

GEO_​VAL

50

N

A/N

This field along with GEO_​TYPE_​CD are used to uniquely identify the service point at which the meter read takes places. These fields are only necessary if you have duplicate BADGE_​NBR's and you have uniquely identified your service points (with a unique GEO_​TYPE_​CD and GEO-VAL - e.g., a universal id). It's important to note that you must also specify the BADGE_​NBR along with the GEO_​TYPE_​CD and GEO_​VAL.

MTR_​ID_​TYPE_​CD

5

N

A/N

See the description of the MTR_​ID_​NBR field.

MTR_​ID_​NBR

30

N

A/N

This field along with MTR_​ID_​TYPE_​CD are used to uniquely identify the meter being read. These fields are only necessary if you do not use the meter's BADGE_​NBR's or the meter's MTR_​CONFIG_​ID to identify the meter.

If specified, this must correspond with a meter ID type / value associated with one of your meters.

USE_​ON_​BILL_​SW

1

Y

A/N

Indicates if the read can be used on a bill. Valid values are Y or N. Note, if the register read's REVIEW_​HILO_​SW is Y and if the register read fails high/low review, the USE_​ON_​BILL_​SW may be set to N if the Use High/Low Failures on Bill is turned on in the installation record.

MTR_​READER_​ID

20

N

A/N

The ID of the meter reader identified by the Meter Read Source, if supplied.