Below is a list of the estimation VEE Rules provided as part of base product that are responsible for filling the missing data within an IMD. For more information on how each rule executes and can be configured, follow the link provided on the rule.
VEE Rule Name |
Applicable Data Type(s) |
Purpose |
Interval |
This rule performs adjustments to interval values based on the values from the associated scalar data on the same device. |
|
Interval |
This rule finds historical interval data from the same measuring component based on a variety of configuration options to use for estimating any missing data within an IMD. |
|
Interval |
This estimation rule creates a new Estimation IMD to fill gaps between the interval data received from the Head End. Note: this estimation rule acts differently from the other rules as it creates a new IMD rather than filling in missing values in an estimation IMD created from periodic estimations. |
|
Interval |
This rule attempts to interpolate gaps within an IMD using prior and subsequent intervals as starting points for linear interpolation. |
|
Interval |
This rule estimates any missing interval data for the IMD based on a referenced Profile Factor. |
|
Interval |
This rule checks for days with similar temperature and uses the measurement data from those days as the basis of interval estimation for the in-flight initial measurement. |
|
Scalar |
This rule performs adjustments to scalar values based on the values from the associated interval data on the same device. |
|
Scalar |
This rule finds historical scalar data from the same measuring component based on a variety of configuration options to use for estimating any missing data within an IMD. |
|
Scalar |
This rule will estimate any missing scalar data for the IMD based on a referenced Profile Factor. |
|
Scalar |
This rule prorates the value of a scalar reading that has two valid scalar readings on either side as boundaries. It will also take into account any related interval data within the same period to exclude from the calculation. |
|
Subtractive Interval |
This rule performs adjustments to qualifying interval consumption values for subtractive interval measuring components based on an adjustment target calculated using a start and stop reading for the period that encapsulates the intervals to adjust. |