Understanding the SCADA Summary Filter Pane
The SCADA Summary provides the following standard Global filters:
Filter Name
Description
All Measurements
Displays all rows in the SCADA Summary table. All is the default view.
AMI Bellwether
Displays bellwether AMI voltage rows.
Analogs
Displays rows with analog values.
Digitals
Displays rows with digital values.
Equipment
Displays rows with equipment values.
Statuses
Displays rows with status value.
Viewing Data in the SCADA Summary
Viewing All SCADA Data
To open the SCADA Summary for all measurements, select SCADA Summary... from the Web Workspace Tools menu.
Viewing SCADA Data for a Selected Device
To open the SCADA Summary for a specific device, select the device or feeder in the Viewer and launch the Control Tool. Click SCADA Summary... and select one of the options:
Device...: loads the SCADA Summary with the SCADA measurement data for the selected device.
Feeder...: loads the SCADA Summary with SCADA measurement data for the selected device's feeder.
Substation...: loads the SCADA Summary with SCADA measurement data for the selected device's substation.
When the SCADA Summary is launched from the Control Tool, the data source is shown in a bar above the table.
Note: If you select Load All from the SCADA Summary Actions menu or click the X button (Red X button.) on the bar above the table, the table will be repopulated with all measurements and the bar will be removed.
Loading SCADA Summary Data for a Different Device
Once the SCADA Summary has been opened (from the Control Tool), you can view data for a different device by selecting it in the Viewer, and then clicking the Load button in the bar above the data table.
Preventing Measurement Updates
To prevent a SCADA measurement from accepting updates from SCADA, complete the following steps:
1. Select SCADA Summary... from the Web Workspace Tools menu. The SCADA Summary window opens.
2. Select a row in the SCADA Summary table corresponding to the device measurement that you want to prevent from updating.
3. Click the Inhibit button.
Manual Entry and Override of SCADA Measurement Values
Occasionally, you may need to manually enter a status, digital value, or analog value for a SCADA measurement. For example, you may need to enter fault current and fault indicators to trigger Fault Location Analysis (if applicable). See Chapter 20, Fault Location Analysis for more information.
If the value for the selected measurement is a switch status measurement (that is, open/close), you must choose Show Control Tool... from the context menu to manually operate the switch. Otherwise, use the following procedure to enter a value manually:
1. Select SCADA Summary... from the Web Workspace Tools menu. The SCADA Summary window opens.
2. Select the SCADA measurement row in the SCADA Summary list.
3. Click either the Manual Entry or Manual Override button.
Note: Manual Entry allows future SCADA value changes to replace the manually entered value. Manual Override prevents SCADA measurements received by the system from changing the manually entered value. Manual Override can be useful when testing specific devices or RTU communications offline, since the test operations can be prevented from creating outages in Oracle Utilities Network Management System by putting manual overrides on the appropriate status measurements.
If the value for the measurement is a multi-state digital, analog, or any type of measurement other than a switch status measurement (open/close), a dialog box opens, allowing you to enter a value.
Note: Multi-state digitals are not available through the Oracle Utilities Network Management System SCADA ICCP Block 1, 2, and 5 Adapter.
4. Select or enter the value you want to change the measurement to.
5. Click OK.
Note: Clicking Manual Override blocks any new values coming from the SCADA measurement. It does not affect the physical SCADA device, it only blocks the value reported by the SCADA device to Oracle Utilities Network Management System.
Adding and Modifying Comments for SCADA Status Changes
When you change the SCADA state to Inhibit, Manual Override, or Disabled in Power Flow, you can enter comments to record why the state was changed. When you initiate Inhibit or Disable in Power Flow actions, a dialog box will open allowing you to enter a comment; for Manual Override, a Comment field is available below the Value field. The comment text, user, and date and time the comment was entered will be added to the selected device's SCADA Summary row.
Existing comments may be edited by selecting the SCADA Summary row and selecting Edit Comment... from the Actions menu.
Disabling/Enabling Measurements in the Power Flow Solution
If you see anomalies in the SCADA data (for example, due to mapping issues, transducer issues, or temporal issues, and so on) where SCADA values seem potentially unhelpful in allowing FLMService to solve, you can disable the suspected measurements from taking part in the power flow solution by doing the following:
1. Select the suspected measurements in the SCADA Summary.
2. Click the Disable in Power Flow button from the Actions menu or the right-click option menu. The Quality column value will be set to S for the selected measurements.
To re-enable the disabled measurements:
1. Select the disabled measurements from the SCADA Summary Tool
2. Click the Enable in Power Flow button from the Actions menu or right-click context menu. The Quality column value will be changed from S to blank for the selected measurements.
SCADA Measurements Trend Graph
The SCADA Trend Graph tool displays historic or real-time trend lines for up to 9 SCADA measurements as long as there are no more than two distinct units of measure (for example, Amps and kW) between them.
The tool contains two main parts: the graph that displays trend lines and the Trends collapsible panel that contains the list of saved SCADA Trend Graph configurations.
Menus and Toolbar Buttons
File Menu
Menu Option
Description
Toolbar Icon
New
Resets the tool to the initial state. Removes all currently displayed trend lines.
--
Load
Loads the trend currently selected in the list of saved trends.
--
Save
Saves the currently displayed trend. If currently displayed trend has not been previously saved user will be prompted to provide unique name.
Save As...
Saves the currently displayed trend under different name. User will be prompted to provide unique name.
--
Delete
Deletes the trend currently selected in list of saved trends.
 
--
Reload
Reloads the list of saved trends.
--
Print...
Prints the trend graph for the selected region.
--
Pin
Click to pin the graph, which will open new graphs in separate windows. If a graph is not pinned, then when the Trend Graph option is selected again, the current window will display the data for the new selection.
Note: You may pin multiple graphs.
Toggle Dockable Window
Changes a standalone window to a pane that may be moved or docked in another window or frame. See Understanding Docked Panes and Standalone Window Tools for more information on dockable and standalone windows.
--
Exit
Closes the Trend Graph window.
--
 
Edit Menu
Menu Option
Description
Toolbar Icon
Add Measurements...
Opens Add Measurements dialog box.
--
Remove Measurements...
Opens Remove Measurements dialog box.
--
Rescale
Reload the data for the currently visible time period. This option is not available in live trending mode. Note: trend lines for which there are no data points in the new time period will not be visible after rescaling.
--
Refresh
Refreshes the displayed trend lines.
Help Menu
Menu Option
Description
Toolbar Icon
Graph Tool Help...
Opens the online help system to the Trend Graph help content.
--
Components of the SCADA Trend Graph
Trends Collapsible Panel
Contains a list of saved SCADA Trend Graph configurations accessible to the user. Each item has a unique name and represents a list of SCADA measurements, type of trend (real-time or historic), and date range.
SCADA Trend Graph configuration can be loaded by double-clicking on an item in the list or using the Load option from the File menu SCADA Trend Graph tool.
Graph Panel
For historic trends, the start and end dates can be changed by selecting a date and time in the Begin Date and End Date fields.
Real-time trending mode can be enabled by the Real-Time check‑box. In this mode, the Begin Date and End Date fields are replaced with the Time Window drop‑down list. Data is displayed for the selected time period going back from the current time.
Newly received values for the displayed measurements are added to the graph dynamically. The graph can show the predicted values and the actual measurements over the given period of time. If you hover the mouse over a point on the graph, the details of the measurement will be shown.