Configuring Silver Spring Networks Extendable Lookups

Note: This section applies to both middleware and native implementations of the Smart Grid Gateway Adapter for Silver Spring Networks.

This section outlines some of the extendable lookups that must be configured for use with the Silver Spring Networks adapter. Refer to the Oracle Utilities Application Framework documentation for more information about working with extendable lookups.

Device Event Mapping

The Device Event Mapping extendable lookup is used to determine which type of device event business object to instantiate when receiving device events from the head-end system. Each value defined for the Device Event Mapping extendable lookup should include the following:

  • Head-End System Event Name: The event name used by the head-end system.

  • Description: A description of the device event.

  • Status: The status of the lookup value (can be Active or Inactive).

  • Standard Event Name: The standard event name for device events of this type, from the “Standard Event Name” extendable lookup.

UOM Code to Standard UOM Mapping

Usage received from a utility’s head-end system may use utility-specific unit of measures (UOMs). These custom UOMs must be mapped to standard UOM codes. The UOM Code to Standard UOM Mapping extendable lookup is used for this purpose. Each value defined for the UOM Code to Standard UOM Mapping extendable lookup should include the following:

  • Head-End Unit of Measure: The unit of measure code used by the head-end system.

  • Description: A description of the unit of measure code.

  • Status: The status of the lookup value (can be Active or Inactive).

  • Unit of Measure: The unit of measure defined in the system.

Interval Status Code to Condition Mapping

Interval usage received from the Silver Spring Networks UtilityIQ can include Silver Spring Networks interval status codes that indicate the status or condition of the interval value. These interval status codes must be mapped to standard condition codes in the system. The Silver Spring Networks Interval Status Code to Condition Mapping extendable lookup is used to determine how to map Silver Spring Networks interval status codes to standard status codes when receiving usage from the Silver Spring Networks UtilityIQ.

Each value defined for the Silver Spring Networks Interval Status Code to Condition Mapping extendable lookup should include the following:

  • Interval Status: The Silver Spring Networks interval status code

  • Description: A description of the interval status code.

  • Status: The status of the lookup value (can be Active or Inactive)

  • Condition: The condition code to which the interval status code is to be mapped, from the Measurement Condition extendable lookup.

Other Extendable Lookups

Business Object Name

Description

 D7-ActivationStatusLookup

 SSN - Activation Status

 D7-ChannelStatusLookup

 SSN - Channel Status

 D7-DataTimeZoneLookup

 SSN - Data Time Zone

 D7-DeviceStatusLookup

 SSN - Device Status

 D7-ExecutionStatusLookup

 SSN - Execution Status

 D7-HeadendSQILookup

 SSN - Head-End SQI to Standard SQI

 D7-HeadendTOULookup

 SSN - Head-End TOU to Standard TOU

 D7-IntervalStatusLookup

 SSN - Interval Status

 D7-MeterConnectionStatusLookup

 SSN - Meter Connection Status

 D7-MeterReadTypeLookup

 SSN - Meter Read Type

 D7-OldAdminStateNameLookup

 SSN - Old Admin State Name

 D7-PriorityLookup

 SSN - Priority Status

 D7-ProvisioningActionLookup

 SSN - Provisioning Action

 D7-ProvisioningCommandStatus

 SSN - Provisioning Command Status

 D7-ProvisioningDataType

 SSN - Provisioning Data Type

 D7-ReadModeLookup

 SSN - Read Mode

 D7-RegisterReadSourceLookup

 SSN - Register Read Source

 D7-RegisterStatusLookup

 SSN - Register Status

 D7-SSNVersionLookup

 SSN - Version

 D7-StatusFlagNameLookup

 SSN - Status Flag Name