CoherenceServerLifeCycleRuntimeMBean, ServerLifeCycleRuntimeMBean, ServerRuntimeMBean, ServerService, ServerStates, SystemComponentLifeCycleRuntimeMBeanpublic interface ServerStates
| Modifier and Type | Field | Description | 
|---|---|---|
| static java.lang.String | ACTIVATE_LATER | Indicates that MaxRestart restart attempts have been made in current RestartInterval, 
 and Node Manager will attempt additional restarts. | 
| static java.lang.String | ADMIN | The server can receive and process only administrative requests. | 
| static java.lang.String | FAILED | A critical subsystem is not functioning. | 
| static java.lang.String | FAILED_NOT_RESTARTABLE | Indicates that the Managed Server has failed and either the Node Manager  AutoRestartattribute is set to false and Node Manager will not restart the Managed Server, or Node Manager 
 has exceeded the configuredRestartMaxvalue for server restarts within the interval defined by  
 theRestartIntervalattribute. | 
| static java.lang.String | FAILED_RESTARTING | Indicates that Node Manager is currently restarting a failed Managed Server. | 
| static java.lang.String | FORCE_SHUTTING_DOWN | The server is transitioning from  ADMINstate toSHUTDOWNforcefully. | 
| static java.lang.String | FORCE_SUSPENDING | The server is transitioning from  RUNNINGstate toADMINforcefully. | 
| static java.lang.String | RESUMING | The server is transitioning from the  ADMINstate toRUNNING. | 
| static java.lang.String | RUNNING | The server can receive and process requests from external clients as
 well as administrative requests. | 
| static java.lang.String | SHUTDOWN | The server is configured but inactive. | 
| static java.lang.String | SHUTDOWN_IN_PROCESS | Deprecated.  | 
| static java.lang.String | SHUTDOWN_PENDING | Deprecated.  | 
| static java.lang.String | SHUTTING_DOWN | The server is transitioning from  ADMINstate toSHUTDOWNgracefully. | 
| static java.lang.String | STANDBY | Services are initialized but are not claiming shared resources. | 
| static java.lang.String | STARTING | The server is starting subsystems that do not use shared resources and 
 need to started early for other subsystems to use them . | 
| static java.lang.String | SUSPENDING | The server is transitioning from  RUNNINGstate toADMINgracefully. | 
| static java.lang.String | UNKNOWN | The state of the server cannot be determined, perhaps because it cannot
 be contacted. | 
static final java.lang.String SHUTDOWN
static final java.lang.String STARTING
STANDBY state after this process completes.static final java.lang.String RUNNING
static final java.lang.String STANDBY
static final java.lang.String ADMIN
static final java.lang.String SUSPENDING
RUNNING state to 
 ADMIN gracefully.static final java.lang.String FORCE_SUSPENDING
RUNNING state to 
 ADMIN forcefully.static final java.lang.String RESUMING
ADMIN state to
 RUNNING.static final java.lang.String SHUTTING_DOWN
ADMIN state to 
 SHUTDOWN gracefully.static final java.lang.String FORCE_SHUTTING_DOWN
ADMIN state to 
 SHUTDOWN forcefully.static final java.lang.String FAILED
@Deprecated static final java.lang.String SHUTDOWN_PENDING
@Deprecated static final java.lang.String SHUTDOWN_IN_PROCESS
static final java.lang.String UNKNOWN
static final java.lang.String FAILED_RESTARTING
static final java.lang.String ACTIVATE_LATER
static final java.lang.String FAILED_NOT_RESTARTABLE
AutoRestart
 attribute is set to false and Node Manager will not restart the Managed Server, or Node Manager 
 has exceeded the configured RestartMax value for server restarts within the interval defined by  
 the RestartInterval attribute.