- Oracle ILOM Protocol Management Reference SNMP and IPMI Firmware Release 5.1.x
- Server Management Using IPMI
- Performing System Management Tasks (IPMItool)
- Display Sensor List
Display Sensor List
-
To view a list of sensors on a managed device, type:
$ ipmitool -I [orcltls|lanplus] -H SP_hostname_or_IPaddress -U
username
-P
password
sdr list
Note:
The IPMI TLS interface (
orcltls
) is supported as of Oracle ILOM firmware version 3.2.8 and later. For a higher level of security, you should always specify the IPMI TLS interface (-I orcltls
) when executing Oracle ILOM commands from the IMPItool utility. For more information about using the IPMI TLS interface from Oracle, see these topics:IPMI TLS Service and Interface and Configure IPMI Management Access for Increased Security in Oracle ILOM Security Guide For Firmware Release 5.1.x.The output might look like the following:
/SYS/T_AMB | 24 degrees C | ok /RFM0/FAN1_SPEED | 7110 RPM | ok /RFM0/FAN2_SPEED | 5880 RPM | ok /RFM1/FAN1_SPEED | 5880 RPM | ok /RFM1/FAN2_SPEED | 6360 RPM | ok /RFM2/FAN1_SPEED | 5610 RPM | ok /RFM2/FAN2_SPEED | 6510 RPM | ok /RFM3/FAN1_SPEED | 6000 RPM | ok /RFM3/FAN2_SPEED | 7110 RPM | ok /RFM4/FAN1_SPEED | 6360 RPM | ok /RFM4/FAN2_SPEED | 5610 RPM | ok /RFM5/FAN1_SPEED | 5640 RPM | ok /RFM5/FAN2_SPEED | 6510 RPM | ok /RFM6/FAN1_SPEED | 6180 RPM | ok /RFM6/FAN2_SPEED | 6000 RPM | ok /RFM7/FAN1_SPEED | 6330 RPM | ok /RFM7/FAN2_SPEED | 6330 RPM | ok /RFM8/FAN1_SPEED | 6510 RPM | ok /RFM8/FAN2_SPEED | 5610 RPM | ok
Note:
The sensor output shown in the preceding example was shortened. The actual output will depend on the hardware platform.