Display Sensor List

Follow this step to display the sensor list for a managed device.

  1. To view a list of sensors on a managed device, type:

    $ ipmitool -I [orcltls|lanplus] -H SP_hostname_or_IPaddress -U
                                  username
                                   -P
                                  password
                              


                                  sdr list
                              

    Note:

    The IPMI TLS interface ( orcltls) is supported as of Oracle ILOM firmware version 3.2.8 and later. For a higher level of security, you should always specify the IPMI TLS interface (-I orcltls) when executing Oracle ILOM commands from the IMPItool utility. For more information about using the IPMI TLS interface from Oracle, see these topics:IPMI TLS Service and Interface and Configure IPMI Management Access for Increased Security in Oracle ILOM Security Guide For Firmware Release 5.1.x.

    The output might look like the following:

    /SYS/T_AMB       | 24 degrees C 		 	 	| ok
    /RFM0/FAN1_SPEED | 7110 RPM          | ok
    /RFM0/FAN2_SPEED | 5880 RPM          | ok
    /RFM1/FAN1_SPEED | 5880 RPM          | ok
    /RFM1/FAN2_SPEED | 6360 RPM          | ok
    /RFM2/FAN1_SPEED | 5610 RPM          | ok
    /RFM2/FAN2_SPEED | 6510 RPM          | ok
    /RFM3/FAN1_SPEED | 6000 RPM          | ok
    /RFM3/FAN2_SPEED | 7110 RPM          | ok
    /RFM4/FAN1_SPEED | 6360 RPM          | ok
    /RFM4/FAN2_SPEED | 5610 RPM          | ok
    /RFM5/FAN1_SPEED | 5640 RPM          | ok
    /RFM5/FAN2_SPEED | 6510 RPM          | ok
    /RFM6/FAN1_SPEED | 6180 RPM          | ok
    /RFM6/FAN2_SPEED | 6000 RPM          | ok
    /RFM7/FAN1_SPEED | 6330 RPM          | ok
    /RFM7/FAN2_SPEED | 6330 RPM          | ok
    /RFM8/FAN1_SPEED | 6510 RPM          | ok
    /RFM8/FAN2_SPEED | 5610 RPM          | ok
    

    Note:

    The sensor output shown in the preceding example was shortened. The actual output will depend on the hardware platform.