- Oracle Exadata X9-2 Database Server Service Manual
- Servicing the Front LED Indicator Module
- Remove the Front LED Indicator Module
Remove the Front LED Indicator Module
-
Prepare the server for service.
- Power off the server and disconnect the power cords from the power supplies.
- Remove the server from the rack.
- Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.
-
Remove the left-side mounting bracket from the server chassis.
- Lift up on the mounting bracket clip to disengage the clip from the chassis locating pin.
- Pull the mounting bracket toward the rear of the chassis until all five chassis locating pins protrude through the five keyhole openings in the mounting bracket.
- Lift the mounting bracket off the locating pins and set it aside.
-
Using a Philips screwdriver, remove the two screws that secure the front
indicator module (FIM) assembly to the server chassis [1].
- Carefully slide the FIM assembly toward the front of the server to remove it from the chassis [2].
-
Using a Phillips screwdriver, remove the two screws that secure the plastic
temperature sensor housing to the FIM assembly, and then detach the housing from
the FIM assembly [2].
Note:
You do not need to remove the temperature sensor from the housing. - Disconnect the FIM cable from the FIM assembly and set the FIM assembly aside [3].
- Continue to Install the Front LED Indicator Module.