24 Monitoring Components and Identifying SNMP Messages
This section includes information about monitoring components and identifying SNMP messages for the Oracle Server X9-2L.
Monitoring Component Health and Faults Using Oracle ILOM
The Oracle ILOM 5.0 interfaces provide easy-to-view information about the health status of system components. From the Oracle ILOM web interface or in the Oracle ILOM command-line interface (CLI), you can collect system-specific information about the server, determine the health state of discrete components, and view any open problems on the server. Oracle ILOM automatically detects system hardware faults and environmental conditions on the server. If a problem occurs on the server, Oracle ILOM automatically does the following:
-
Illuminate the Fault-Service Required LED status indicator on the server front and back panels. See Troubleshooting Using the Server Front and Back Panel Status Indicators and Monitoring System Components.
-
Identify the faulted component in the Open Problems table. Open problems detected on a host server or system chassis are viewable from either the Open Problems web page or the /System/Open_problems CLI target. Refer to View Open Problems Detected on a Managed Device in the Oracle ILOM User's Guide for System Monitoring and Diagnostics Firmware Release 5.0.x at Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation.
-
Record system information about the faulted component or condition in the Oracle ILOM event log. Refer to Managing ILOM Log Entries in the Oracle ILOM User's Guide for System Monitoring and Diagnostics Firmware Release 5.0.x at Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation.
For further information about administering open problems that are detected and reported by Oracle ILOM, refer to Administering Open Problems in the Oracle ILOM Administrator's Guide for Configuration and Maintenance Firmware Release 5.0.x at Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation.
Monitoring System Components
The tables in this section identify the system components and describe the naming conventions applied to the components of Oracle Server X9-2L.
Each section corresponds to an IPMI entity ID and lists sensors, indicators, and field-replaceable units (FRUs) related to that entity. The tables contain the following fields:
-
Component Name – Shows the user-visible component name used in management interfaces to refer to a specific sensor, indicator, or FRU. The IPMI name is a shortened form of the component name, and is indicated by the boldface portion of the component name.
-
IPMI Type – Indicates the type of sensor, indicator, or FRU represented.
-
Description – Describes the particular component name reference.
-
Values – Defines the states of the sensor, indicator, or FRU entity, and any specific units or values that are expected, if applicable.
Note:
Some component names are hidden in the Oracle ILOM user interfaces. As of Oracle ILOM 3.2, the Oracle ILOM 3.0 legacy targets/SYS
and /STORAGE
were replaced by /System
. Even though these legacy targets might be hidden, you can still use them to issue commands. For information on legacy targets, see the ILOM 3.2 Documentation Library at Systems Management and Diagnostics Documentation.
This section includes information for the following server components:
System Chassis Components
The following table lists the system chassis components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS |
FRU |
Product information only |
|
/SYS/UUID |
FRU |
Unique system ID |
Derived from host MAC address. Used for PXE boot and licensing. |
/SYS/ACPI |
State sensor |
Advanced Configuration and Power Interface |
01h-ACPI_ON_WORKING 20h-ACPI_SOFT_OFF |
/SYS/VPS |
Threshold sensor |
Virtual power consumption sensor |
Watts |
/SYS/VPS_CPUS |
Threshold sensor |
Virtual power sensor - CPU power consumption |
Watts |
/SYS/VPS_MEMORY |
Threshold sensor |
Virtual power sensor - memory power consumption |
Watts |
/SYS/VPS_FANS |
Threshold sensor |
Virtual power sensor - fan power consumption |
Watts |
/SYS/T_AMB |
Threshold sensor |
Ambient temperature on system motherboard |
Degrees Celsius |
/SYS/TEMP_FAULT |
Indicator |
Temperature Fault LED |
Color: Amber Location: Front panel Off: Normal On: Chassis overtemp fault |
/SYS/OK |
Indicator |
System OK LED |
Color: Green Location: Front and back panels Off: Power is off. Standby blink: Host is off, awaiting Power On. Slow blink: Startup sequence initiated on host. On: Host is booting OS or running the OS. |
/SYS/SERVICE |
Indicator |
Fault-Service Required LED |
Color: Amber Location: Front and back panels Off: Normal On: Server requires service. |
/SYS/LOCATE |
Indicator |
Locate Button/LED |
Color: White Location: Front and back panels Off: Normal Fast blink: Locate function is activated; self-extinguishes after 30 minutes. |
/SYS/PS_FAULT |
Indicator |
Rear Power Supply Fault LED |
Color: Amber Location: Front panel Off: Normal On: General power supply fault |
/SYS/FAN_FAULT |
Indicator |
Top Fan Fault LED |
Color: Amber Location: Front panel Off: Normal On: General fan fault |
/SYS/DO_NOT_SERVICE |
Indicator |
Do Not Service LED |
Color: White Location: Front panel Off: Normal On: Do not service this cell |
Cooling Unit Components
The system has four 80-mm fan modules with two fans in each module. The following table lists the system cooling unit components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/MB/FM[0-3] |
FRU |
Fan module FRU |
|
/SYS/MB/FM[0-3]/F[0- x ] |
FRU |
Individual fan |
|
/SYS/MB/FM[0-3] /PRSNT |
Discrete sensor |
Fan module is present. |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/FM[0-3] /F[0-x]/TACH |
Threshold sensor |
Fan module fan speed |
RPM |
/SYS/MB/FM[0-3] /SERVICE |
Indicator |
Fan Fault-Service Required LED |
Color: Amber Location: Motherboard Off: Normal On: Fan module was diagnosed as faulty. |
Disk Backplane Components
The following table lists the disk backplane (DBP) components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/DBP |
FRU |
Disk backplane FRU |
|
/SYS/DBP/CPLD |
FRU |
Disk backplane complex programmable logic device (CPLD)/field programmable gate array (FPGA) firmware FRU |
|
/SYS/DBP/PRSNT |
Discrete sensor |
Disk backplane presence (Hidden) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/DBP/HDD[0- x ] |
FRU |
Hard disk drives (HDD) |
|
/SYS/DBP/HDD[0- x ]/PRSNT |
Discrete sensor |
Hard disk drive presence(Hidden) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/DBP/HDD[0- x ]/STATE |
State sensor |
Hard disk drive state |
01h-FAULT_STATUS 02h-IDENTITY 04h-INSTALLED 20h-SLOT_POWER_OFF |
/SYS/DBP/HDD[0- x ]/SERVICE |
Indicator |
Fault-Service Required LED |
Color: Amber Location: HDD Off: Normal On: HDD was diagnosed as failed |
/SYS/DBP/HDD[0- x ]/OK2RM |
Indicator |
Hard disk drive OK to remove |
Color: Blue Location: HDD Off: Normal On: HDD is OK to remove |
/SYS/DBP/HDD[0- x ]/NVME |
FRU |
NVMe drive FRU |
|
/SYS/DBP/HDD[0- x ]/NVME/PRSNT |
Discrete sensor |
NVMe device presence |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/VREG_DBP_ERR |
Discrete sensor |
Disk backplane voltage regulator-down (VRD) error (Hidden) |
01h-DEASSERTED 02h-ASSERTED |
/SYS/VREG_USB_ERR |
Discrete sensor |
Universal Serial Bus (USB) VRD error (Hidden) |
01h-DEASSERTED 02h-ASSERTED |
Memory Device Components
The following table lists the memory device components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/MB/P[0- x ]/D[0-15] |
FRU |
Host CPU DIMM FRU |
|
/SYS/MB/P[0-1 ]/D[0-15]/PRSNT |
Discrete sensor |
Host CPU DIMM is present. |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/P[0- x ]/D[0-15]/SERVICE |
Indicator |
Host CPU DIMM Fault-Service Required LED |
Color: Amber Location: Motherboard Off: Normal On: DIMM was diagnosed as faulty. |
/SYS/MB/P[0-1]/D[0-15]/TEMP |
Discrete sensor |
Host CPU DIMM temperature sensor (Hidden) |
Power Unit Components
The following table lists the power unit components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/PDB |
FRU |
Power distribution board FRU |
|
/SYS/PS[0-1] |
FRU |
Power supply FRU |
|
/SYS/PS[0-1]/PRSNT |
Discrete sensor |
Power supply is present. (Hidden) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/PS[0-1]/STATE |
State sensor |
Power supply state sensor Multistate, power supply sensor type, per IPMI |
Presence detected Failure detected Predictive failure Power supply input lost Power supply input lost or out-of-range Power supply input out-of-range Configuration error |
/SYS/PS[0-1]/P_IN |
Threshold sensor |
Input power draw |
Watts |
/SYS/PS[0-1]/P_OUT |
Threshold sensor |
Output power |
Watts |
/SYS/PS[0-1]/V_IN |
Threshold sensor |
Power supply input voltage |
Volts |
/SYS/PS[0-1]/V_12V |
Threshold sensor |
Power supply 12V output voltage |
Volts |
/SYS/PS[0-1]/V_12V_STBY |
Threshold sensor |
Power supply 12V standby output voltage |
Volts |
/SYS/PS[0-1]/T_IN |
Threshold sensor |
PSU input temperature |
Degrees Celsius |
/SYS/PS[0-1]/T_OUT |
Threshold sensor |
PSU output temperature |
Degrees Celsius |
Processor Components
The following table lists the processor (CPU) components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/MB/P[0- x ] |
FRU |
Host CPU FRU |
|
/SYS/MB/P[0-1 ]/PRSNT |
Discrete sensor |
Host CPU is present. |
01h-ENTITY_PRESENT 02h-ENTITY_ABSENT |
/SYS/MB/P[0- x ]/SERVICE |
Indicator |
Host CPU Fault-Service Required LED |
Color: Amber Location: Motherboard Off: Normal On: Processor was diagnosed as faulty. |
System Motherboard Components
The following table lists the system motherboard components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/MB |
FRU |
General host system motherboard FRU |
|
/SYS/MB/NET[0 ] |
FRU |
Host Ethernet FRU |
|
/SYS/MB/PCIE[1-10] |
FRU |
PCIe slot |
|
/SYS/MB/PCIE[1-10]/POWER |
Indicator |
PCIe slot power indicator |
Color: Green Location: Motherboard On: Power is on Off: Power is off |
/SYS/MB/PCIE[1-10]/PRSNT |
Discrete |
PCIe slot is occupied. |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/PCIE[1-10]/SERVICE |
Indicator |
PCIe slot service indicator |
Color: Amber Location: Motherboard On: Service required Off: Normal |
/SYS/MB/PCIE10/RETIMER |
FRU |
Optional PCIe retimer in slot 10 (2U only) |
|
/SYS/MB/PCIE10/RETIMER/PRSNT |
Discrete |
Optional PCIe retimer card is present in slot 10 (only supported slot) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/RISER[1-3]/PRSNT |
Discrete sensor |
PCIe slot riser is present |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/ROT |
FRU |
Root of trust FRU |
|
/SYS/MB/T_IN_ZONE[0-3] |
Threshold sensor |
Cooling zone input temperature sensor |
Degrees Celsius |
/SYS/MB/T_OUT_ZONE[0-3] |
Threshold sensor |
Cooling zone output temperature sensor |
Degrees Celsius |
/SYS/SP |
FRU |
Service processor FRU |
|
/SYS/SP/OK |
Indicator |
SP OK LED |
Color: Green Location: Front panel On: SP is operating. Off: SP requires service. |
/SYS/SP/NET[0-1] |
FRU |
SP Ethernet FRU |
System Firmware Components
The following table lists the system firmware components.
Component Name (Oracle ILOM CLI Target) | IPMI Type | Description |
---|---|---|
/SYS/MB/BIOS |
FRU |
BIOS FRU |
/SYS/MB/CPLD |
FRU |
Motherboard complex programmable logic device (CPLD)/field programmable gate array (FPGA) firmware version |
Disk Drive Components
The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/DBP/HDD[0- x ] |
FRU |
Hard disk drive FRU |
From host |
/SYS/DBP/HDD[0- x ]/PRSNT |
Discrete sensor |
Hard disk drive presence |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/DBP/HDD[0- x ]/STATE |
Discrete sensor |
Writable multistate, slot/connector sensor type, per IPMI |
01h-FAULT_STATUS 02h-IDENTITY 04h-INSTALLED 20h-SLOT_POWER_OFF |
/SYS/DBP/HDD[0- x ]/SERVICE |
Indicator |
Hard disk drive Fault-Service Required LED |
Color: Amber Location: HDD Off: Normal On: Hard disk drive was diagnosed as faulty. |
/SYS/DBP/HDD[0- x ]/OK2RM |
Indicator |
Hard disk drive OK to Remove LED |
Color: Blue Location: HDD Off: Normal On: Drive is ready to remove. |
/SYS/DBP/HDD[0- x ]/NVME |
FRU |
NVMe drive FRU |
|
/SYS/DBP/HDD[0- x ]/NVME/PRSNT |
Discrete sensor |
NVMe device presence |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/SSDR[0-1] |
FRU |
Internal SSD riser (1 on 1U, 2 on 2U) FRU |
|
/SYS/MB/SSDR[0-1]/PRSNT |
Discrete sensor |
Solid-state drive (SSD) riser presence (2 risers on 2U) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/SSDR[0-1]/SSD[0-1] |
FRU |
Internal SSD drive FRU |
|
/SYS/MB/SSDR[0-1]/SSD[0-1]/PRSNT |
Discrete sensor |
SSD drive presence (1 SSD per riser on 2U) (Hidden) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/SSDR[0-1]/SSD[0-1]/STATE |
State sensor |
SSD drive state |
04h-INSTALLED 20h-SLOT POWER OFF |
/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME |
FRU |
Internal SSD that is NVM Express FRU |
|
/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME/PRSNT |
Discrete sensor |
Indicates the SSD is PCIe (NVMExpress) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
Identifying SNMP Trap Messages
You can configure Oracle ILOM to generate Simple Network Management Protocol (SNMP) traps when hardware problems occur. For information about how to configure SNMP alert rule destinations to start receiving these traps, refer to the Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation.
The tables in these sections list the set of SNMP traps that are generated from Oracle ILOM.
Environmental Events
The following table lists environmental events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapTempFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_ZONE[0-2] /SYS/MB/T_OUT_ZONE[0-2] |
SNMP Trap: sunHwTrapTempFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_ZONE[0-2] /SYS/MB/T_OUT_ZONE[0-2] |
SNMP Trap: sunHwTrapTempCritThresholdExceeded Oracle ILOM Event Message: Upper critical threshold exceeded Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_ZONE[0-2] /SYS/MB/T_OUT_ZONE[0-2] |
SNMP Trap: sunHwTrapTempCritThresholdDeasserted Oracle ILOM Event Message: Upper critical threshold no longer exceeded Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/T_OUT /SYS/PS[0-1]/T_IN /SYS/MB/T_IN_ZONE[0-2] /SYS/MB/T_OUT_ZONE[0-2] |
SNMP Trap: sunHwTrapTempFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/T_AMB |
SNMP Trap: sunHwTrapTempFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/T_AMB |
Hard Disk Drive Events
The following table lists hard disk drive events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapSlotOrConnectorError Oracle ILOM Event Message: Assert Severity and Description: Major: A sensor associated with a slot or connector has detected an error. |
/SYS/DBP/HDD[0-x]/STATE |
SNMP Trap: sunHwTrapSlotOrConnectorOk Oracle ILOM Event Message: Deassert Severity and Description: Informational; A sensor associated with a slot or connector has returned to its normal state. |
/SYS/DBP/HDD[0-x]/STATE |
Power Events
The following table lists power events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_PRESENCE ASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_PRESENCE DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_FAILURE ASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_FAILURE DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_PREDICTIVE_FAILURE ASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_PREDICTIVE_FAILURE DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_INPUT_LOST ASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_INPUT_LOST DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_INPUT_ERROR ASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_INPUT_ERROR DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_INPUT_RANGE_ERROR ASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_INPUT_RANGE_ERROR DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyError Oracle ILOM Event Message: PS_CONFIG_ERROR ASSERT Severity and Description Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapPowerSupplyOk Oracle ILOM Event Message: PS_CONFIG_ERROR DEASSERT Severity and Description: Major; A power supply sensor has detected an error. |
/SYS/PS[0-1]/STATE |
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded Oracle ILOM Event Message: Upper noncritical threshold exceeded Severity and Description: Minor; A sensor has reported that its value has gone above an upper non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/VPS |
SNMP Trap: sunHwTrapSensorThresholdOk Oracle ILOM Event Message:Upper noncritical threshold no longer exceeded Severity and Description: Informational; A sensor has reported that its value is in the normal operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. |
/SYS/VPS |
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded Oracle ILOM Event Message: Upper noncritical threshold exceeded Severity and Description: Minor; A sensor has reported that its value has gone above an upper noncritical threshold setting or below a lower noncritical threshold setting. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/VPS_FANS /SYS/PS[0-1]/P_IN /SYS/PS[0-1]/P_OUT |
SNMP Trap: sunHwTrapSensorThresholdOk Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded Severity and Description: Informational; A sensor has reported that its value is in the normal operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. |
/SYS/VPS_FANS /SYS/PS[0-1]/P_IN /SYS/PS[0-1]/P_OUT |
SNMP Trap: sunHwTrapSensorFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A power supply sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/P_IN /SYS/PS[0-1]/P_OUT |
SNMP Trap: sunHwTrapSensorFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A power supply sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/P_IN /SYS/PS[0-1]/P_OUT |
SNMP Trap: sunHwTrapSensorCritThresholdExceeded Oracle ILOM Event Message: Lower critical threshold exceeded Severity and Description: Major; A power supply sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/P_IN /SYS/PS[0-1]/P_OUT |
SNMP Trap: sunHwTrapSensorCritThresholdDeasserted Oracle ILOM Event Message: Lower critical threshold no longer exceeded Severity and Description: Informational; A power supply sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/P_IN /SYS/PS[0-1]/P_OUT |
SNMP Trap: sunHwTrapVoltageFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A voltage sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/V_12V /SYS/PS[0-1]/V_12V_STBY /SYS/PS[0-1]/V_IN |
SNMP Trap: sunHwTrapVoltageFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A voltage sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/V_12V /SYS/PS[0-1]/V_12V_STBY /SYS/PS[0-1]/V_IN |
SNMP Trap: sunHwTrapVoltageCritThresholdExceeded Oracle ILOM Event Message: Upper critical threshold exceeded Severity and Description: Critical; A voltage sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/V_12V /SYS/PS[0-1]/V_12V_STBY /SYS/PS[0-1]/V_IN |
SNMP Trap: sunHwTrapVoltageCritThresholdDeasserted Oracle ILOM Event Message: Upper critical threshold no longer exceeded Severity and Description: Informational; A voltage sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/V_12V /SYS/PS[0-1]/V_12V_STBY /SYS/PS[0-1]/V_IN |
SNMP Trap: sunHwTrapVoltageNonCritThresholdExceeded Oracle ILOM Event Message: Upper noncritical threshold exceeded Severity and Description: Minor; A voltage sensor has reported that its value has gone above an upper noncritical threshold setting or below a lower noncritical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/PS[0-1]/V_12V /SYS/PS[0-1]/V_12V_STBY /SYS/PS[0-1]/V_IN |
SNMP Trap: sunHwTrapVoltageOk Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded Severity and Description: Informational; A voltage sensor has reported that its value is in the normal operating range. |
/SYS/PS[0-1]/V_12V /SYS/PS[0-1]/V_12V_STBY /SYS/PS[0-1]/V_IN |
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded Oracle ILOM Event Message: Upper noncritical threshold exceeded Severity and Description: Minor; A sensor has reported that its value has gone above an upper noncritical threshold setting or below a lower noncritical threshold setting. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/VPS_CPUS /SYS/VPS_MEMORY |
SNMP Trap: sunHwTrapSensorThresholdOk Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded Severity and Description: Informational; A sensor has reported that its value is in the normal operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type. |
/SYS/VPS_CPUS /SYS/VPS_MEMORY |
Fan Events
The following table lists fan events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapFanSpeedCritThresholdExceeded Oracle ILOM Event Message: Lower critical threshold exceeded Severity and Description: Major; A fan speed sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/MB/FM[0-3]/F[0-x]/TACH |
SNMP Trap: sunHwTrapFanSpeedCritThresholdDeasserted Oracle ILOM Event Message: Lower critical threshold no longer exceeded Severity and Description: Informational; A fan speed sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/MB/FM[0-3]/F[0-x]/TACH |
SNMP Trap: sunHwTrapFanSpeedFatalThresholdExceeded Oracle ILOM Event Message: Lower fatal threshold exceeded Severity and Description: Critical; A fan speed sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/MB/FM[0-3]/F[0-x]/TACH |
SNMP Trap: sunHwTrapFanSpeedFatalThresholdDeasserted Oracle ILOM Event Message: Lower fatal threshold no longer exceeded Severity and Description: Informational; A fan speed sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting. The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold. |
/SYS/MB/FM[0-3]/F[0-x]/TACH |
Memory Events
The following table lists memory events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapMemoryFault Oracle ILOM Event Message: event fault.cpu.intel.quickpath.link_slow "The Quickpath Interconnect (QPI) link is operating below normal speed." Severity and Description: Major; A memory component is suspected of causing a fault. |
/SYS/MB |
SNMP Trap: sunHwTrapMemoryFaultCleared Oracle ILOM Event Message: event fault.cpu.intel.quickpath.link_slow "The Quickpath Interconnect (QPI) link is operating below normal speed." Severity and Description: Informational; A memory component fault has been cleared. |
/SYS/MB |
SNMP Trap: sunHwTrapMemoryFault Oracle ILOM Event Message: event fault.cpu.intel.quickpath.unknown-errcode "An unknown error code from the Quickpath Interconnect (QPI) reference code has been detected." Severity and Description: Major; A memory component is suspected of causing a fault. |
/SYS/MB |
SNMP Trap: sunHwTrapMemoryFaultCleared Oracle ILOM Event Message: event fault.cpu.intel.quickpath.unknown-errcode "An unknown error code from the Quickpath Interconnect (QPI) reference code has been detected." Severity and Description: Informational; A memory component fault has been cleared. |
/SYS/MB |
Entity Presence Events
The following table lists entity presence events.
Messages and Descriptions | Component Name |
---|---|
SNMP Trap: sunHwTrapProcessorError Oracle ILOM Event Message: ENTITY_PRESENT ASSERT Severity and Description: Major; A processor sensor has detected an error. Device absent. |
/SYS/MB/P[0-x]/PRSNT |
SNMP Trap: sunHwTrapProcessorOk Oracle ILOM Event Message: ENTITY_PRESENT DEASSERT Severity and Description: Major; A processor sensor has returned to its normal state. Device present. |
/SYS/MB/P[0-x]/PRSNT |
SNMP Trap: sunHwTrapProcessorError Oracle ILOM Event Message: ENTITY_DISABLED ASSERT Severity and Description: Major; A processor sensor has detected an error. Device disabled. |
/SYS/MB/P[0-x]/PRSNT |
SNMP Trap: sunHwTrapProcessorOk Oracle ILOM Event Message: ENTITY_DISABLED DEASSERT Severity and Description: Major; A processor sensor has returned to its normal state. Device enabled. |
/SYS/MB/P[0-x]/PRSNT |