24 Monitoring Components and Identifying SNMP Messages

This section includes information about monitoring components and identifying SNMP messages for the Oracle Server X9-2L.

Monitoring Component Health and Faults Using Oracle ILOM

The Oracle ILOM 5.0 interfaces provide easy-to-view information about the health status of system components. From the Oracle ILOM web interface or in the Oracle ILOM command-line interface (CLI), you can collect system-specific information about the server, determine the health state of discrete components, and view any open problems on the server. Oracle ILOM automatically detects system hardware faults and environmental conditions on the server. If a problem occurs on the server, Oracle ILOM automatically does the following:

For further information about administering open problems that are detected and reported by Oracle ILOM, refer to Administering Open Problems in the Oracle ILOM Administrator's Guide for Configuration and Maintenance Firmware Release 5.0.x at Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation.

Monitoring System Components

The tables in this section identify the system components and describe the naming conventions applied to the components of Oracle Server X9-2L.

Each section corresponds to an IPMI entity ID and lists sensors, indicators, and field-replaceable units (FRUs) related to that entity. The tables contain the following fields:

  • Component Name – Shows the user-visible component name used in management interfaces to refer to a specific sensor, indicator, or FRU. The IPMI name is a shortened form of the component name, and is indicated by the boldface portion of the component name.

  • IPMI Type – Indicates the type of sensor, indicator, or FRU represented.

  • Description – Describes the particular component name reference.

  • Values – Defines the states of the sensor, indicator, or FRU entity, and any specific units or values that are expected, if applicable.

Note:

Some component names are hidden in the Oracle ILOM user interfaces. As of Oracle ILOM 3.2, the Oracle ILOM 3.0 legacy targets /SYS and /STORAGE were replaced by /System. Even though these legacy targets might be hidden, you can still use them to issue commands. For information on legacy targets, see the ILOM 3.2 Documentation Library at Systems Management and Diagnostics Documentation.

This section includes information for the following server components:

System Chassis Components

The following table lists the system chassis components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS

FRU

Product information only

/SYS/UUID

FRU

Unique system ID

Derived from host MAC address. Used for PXE boot and licensing.

/SYS/ACPI

State sensor

Advanced Configuration and Power Interface

01h-ACPI_ON_WORKING

20h-ACPI_SOFT_OFF

/SYS/VPS

Threshold sensor

Virtual power consumption sensor

Watts

/SYS/VPS_CPUS

Threshold sensor

Virtual power sensor - CPU power consumption

Watts

/SYS/VPS_MEMORY

Threshold sensor

Virtual power sensor - memory power consumption

Watts

/SYS/VPS_FANS

Threshold sensor

Virtual power sensor - fan power consumption

Watts

/SYS/T_AMB

Threshold sensor

Ambient temperature on system motherboard

Degrees Celsius

/SYS/TEMP_FAULT

Indicator

Temperature Fault LED

Color: Amber

Location: Front panel

Off: Normal

On: Chassis overtemp fault

/SYS/OK

Indicator

System OK LED

Color: Green

Location: Front and back panels

Off: Power is off.

Standby blink: Host is off, awaiting Power On.

Slow blink: Startup sequence initiated on host.

On: Host is booting OS or running the OS.

/SYS/SERVICE

Indicator

Fault-Service Required LED

Color: Amber

Location: Front and back panels

Off: Normal

On: Server requires service.

/SYS/LOCATE

Indicator

Locate Button/LED

Color: White

Location: Front and back panels

Off: Normal

Fast blink: Locate function is activated; self-extinguishes after 30 minutes.

/SYS/PS_FAULT

Indicator

Rear Power Supply Fault LED

Color: Amber

Location: Front panel

Off: Normal

On: General power supply fault

/SYS/FAN_FAULT

Indicator

Top Fan Fault LED

Color: Amber

Location: Front panel

Off: Normal

On: General fan fault

/SYS/DO_NOT_SERVICE

Indicator

Do Not Service LED

Color: White

Location: Front panel

Off: Normal

On: Do not service this cell

Cooling Unit Components

The system has four 80-mm fan modules with two fans in each module. The following table lists the system cooling unit components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB/FM[0-3]

FRU

Fan module FRU

/SYS/MB/FM[0-3]/F[0- x ]

FRU

Individual fan

/SYS/MB/FM[0-3] /PRSNT

Discrete sensor

Fan module is present.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/FM[0-3] /F[0-x]/TACH

Threshold sensor

Fan module fan speed

RPM

/SYS/MB/FM[0-3] /SERVICE

Indicator

Fan Fault-Service Required LED

Color: Amber

Location: Motherboard

Off: Normal

On: Fan module was diagnosed as faulty.

Disk Backplane Components

The following table lists the disk backplane (DBP) components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/DBP

FRU

Disk backplane FRU

/SYS/DBP/CPLD

FRU

Disk backplane complex programmable logic device (CPLD)/field programmable gate array (FPGA) firmware FRU

 

/SYS/DBP/PRSNT

Discrete sensor

Disk backplane presence (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]

FRU

Hard disk drives (HDD)

/SYS/DBP/HDD[0- x ]/PRSNT

Discrete sensor

Hard disk drive presence(Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]/STATE

State sensor

Hard disk drive state

01h-FAULT_STATUS

02h-IDENTITY

04h-INSTALLED

20h-SLOT_POWER_OFF

/SYS/DBP/HDD[0- x ]/SERVICE

Indicator

Fault-Service Required LED

Color: Amber

Location: HDD

Off: Normal

On: HDD was diagnosed as failed

/SYS/DBP/HDD[0- x ]/OK2RM

Indicator

Hard disk drive OK to remove

Color: Blue

Location: HDD

Off: Normal

On: HDD is OK to remove

/SYS/DBP/HDD[0- x ]/NVME

FRU

NVMe drive FRU

/SYS/DBP/HDD[0- x ]/NVME/PRSNT

Discrete sensor

NVMe device presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/VREG_DBP_ERR

Discrete sensor

Disk backplane voltage regulator-down (VRD) error (Hidden)

01h-DEASSERTED

02h-ASSERTED

/SYS/VREG_USB_ERR

Discrete sensor

Universal Serial Bus (USB) VRD error (Hidden)

01h-DEASSERTED

02h-ASSERTED

Memory Device Components

The following table lists the memory device components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB/P[0- x ]/D[0-15]

FRU

Host CPU DIMM FRU

/SYS/MB/P[0-1 ]/D[0-15]/PRSNT

Discrete sensor

Host CPU DIMM is present.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/P[0- x ]/D[0-15]/SERVICE

Indicator

Host CPU DIMM Fault-Service Required LED

Color: Amber

Location: Motherboard

Off: Normal

On: DIMM was diagnosed as faulty.

/SYS/MB/P[0-1]/D[0-15]/TEMP

Discrete sensor

Host CPU DIMM temperature sensor (Hidden)

 

Power Unit Components

The following table lists the power unit components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/PDB

FRU

Power distribution board FRU

 

/SYS/PS[0-1]

FRU

Power supply FRU

/SYS/PS[0-1]/PRSNT

Discrete sensor

Power supply is present. (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/PS[0-1]/STATE

State sensor

Power supply state sensor

Multistate, power supply sensor type, per IPMI

Presence detected

Failure detected

Predictive failure

Power supply input lost

Power supply input lost or out-of-range

Power supply input out-of-range

Configuration error

/SYS/PS[0-1]/P_IN

Threshold sensor

Input power draw

Watts

/SYS/PS[0-1]/P_OUT

Threshold sensor

Output power

Watts

/SYS/PS[0-1]/V_IN

Threshold sensor

Power supply input voltage

Volts

/SYS/PS[0-1]/V_12V

Threshold sensor

Power supply 12V output voltage

Volts

/SYS/PS[0-1]/V_12V_STBY

Threshold sensor

Power supply 12V standby output voltage

Volts

/SYS/PS[0-1]/T_IN

Threshold sensor

PSU input temperature

Degrees Celsius

/SYS/PS[0-1]/T_OUT

Threshold sensor

PSU output temperature

Degrees Celsius

Processor Components

The following table lists the processor (CPU) components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB/P[0- x ]

FRU

Host CPU FRU

/SYS/MB/P[0-1 ]/PRSNT

Discrete sensor

Host CPU is present.

01h-ENTITY_PRESENT

02h-ENTITY_ABSENT

/SYS/MB/P[0- x ]/SERVICE

Indicator

Host CPU Fault-Service Required LED

Color: Amber

Location: Motherboard

Off: Normal

On: Processor was diagnosed as faulty.

System Motherboard Components

The following table lists the system motherboard components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB

FRU

General host system motherboard FRU

/SYS/MB/NET[0 ]

FRU

Host Ethernet FRU

/SYS/MB/PCIE[1-10]

FRU

PCIe slot

 

/SYS/MB/PCIE[1-10]/POWER

Indicator

PCIe slot power indicator

Color: Green

Location: Motherboard

On: Power is on

Off: Power is off

/SYS/MB/PCIE[1-10]/PRSNT

Discrete

PCIe slot is occupied.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/PCIE[1-10]/SERVICE

Indicator

PCIe slot service indicator

Color: Amber

Location: Motherboard

On: Service required

Off: Normal

/SYS/MB/PCIE10/RETIMER

FRU

Optional PCIe retimer in slot 10 (2U only)

 

/SYS/MB/PCIE10/RETIMER/PRSNT

Discrete

Optional PCIe retimer card is present in slot 10 (only supported slot)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/RISER[1-3]/PRSNT

Discrete sensor

PCIe slot riser is present

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/ROT

FRU

Root of trust FRU

 

/SYS/MB/T_IN_ZONE[0-3]

Threshold sensor

Cooling zone input temperature sensor

Degrees Celsius

/SYS/MB/T_OUT_ZONE[0-3]

Threshold sensor

Cooling zone output temperature sensor

Degrees Celsius

/SYS/SP

FRU

Service processor FRU

/SYS/SP/OK

Indicator

SP OK LED

Color: Green

Location: Front panel

On: SP is operating.

Off: SP requires service.

/SYS/SP/NET[0-1]

FRU

SP Ethernet FRU

System Firmware Components

The following table lists the system firmware components.

Component Name (Oracle ILOM CLI Target) IPMI Type Description

/SYS/MB/BIOS

FRU

BIOS FRU

/SYS/MB/CPLD

FRU

Motherboard complex programmable logic device (CPLD)/field programmable gate array (FPGA) firmware version

Disk Drive Components

The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/DBP/HDD[0- x ]

FRU

Hard disk drive FRU

From host

/SYS/DBP/HDD[0- x ]/PRSNT

Discrete sensor

Hard disk drive presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]/STATE

Discrete sensor

Writable multistate, slot/connector sensor type, per IPMI

01h-FAULT_STATUS

02h-IDENTITY

04h-INSTALLED

20h-SLOT_POWER_OFF

/SYS/DBP/HDD[0- x ]/SERVICE

Indicator

Hard disk drive Fault-Service Required LED

Color: Amber

Location: HDD

Off: Normal

On: Hard disk drive was diagnosed as faulty.

/SYS/DBP/HDD[0- x ]/OK2RM

Indicator

Hard disk drive OK to Remove LED

Color: Blue

Location: HDD

Off: Normal

On: Drive is ready to remove.

/SYS/DBP/HDD[0- x ]/NVME

FRU

NVMe drive FRU

/SYS/DBP/HDD[0- x ]/NVME/PRSNT

Discrete sensor

NVMe device presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]

FRU

Internal SSD riser (1 on 1U, 2 on 2U) FRU

 

/SYS/MB/SSDR[0-1]/PRSNT

Discrete sensor

Solid-state drive (SSD) riser presence (2 risers on 2U)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]/SSD[0-1]

FRU

Internal SSD drive FRU

 

/SYS/MB/SSDR[0-1]/SSD[0-1]/PRSNT

Discrete sensor

SSD drive presence (1 SSD per riser on 2U) (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]/SSD[0-1]/STATE

State sensor

SSD drive state

04h-INSTALLED

20h-SLOT POWER OFF

/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME

FRU

Internal SSD that is NVM Express FRU

 

/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME/PRSNT

Discrete sensor

Indicates the SSD is PCIe (NVMExpress)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

Identifying SNMP Trap Messages

You can configure Oracle ILOM to generate Simple Network Management Protocol (SNMP) traps when hardware problems occur. For information about how to configure SNMP alert rule destinations to start receiving these traps, refer to the Oracle Integrated Lights Out Manager (ILOM) 5.0 Documentation.

The tables in these sections list the set of SNMP traps that are generated from Oracle ILOM.

Environmental Events

The following table lists environmental events.

Messages and Descriptions Component Name

SNMP Trap: sunHwTrapTempFatalThresholdExceeded

Oracle ILOM Event Message: Lower fatal threshold exceeded

Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/T_OUT

/SYS/PS[0-1]/T_IN

/SYS/MB/T_IN_ZONE[0-2]

/SYS/MB/T_OUT_ZONE[0-2]

SNMP Trap: sunHwTrapTempFatalThresholdDeasserted

Oracle ILOM Event Message: Lower fatal threshold no longer exceeded

Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/T_OUT

/SYS/PS[0-1]/T_IN

/SYS/MB/T_IN_ZONE[0-2]

/SYS/MB/T_OUT_ZONE[0-2]

SNMP Trap: sunHwTrapTempCritThresholdExceeded

Oracle ILOM Event Message: Upper critical threshold exceeded

Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/T_OUT

/SYS/PS[0-1]/T_IN

/SYS/MB/T_IN_ZONE[0-2]

/SYS/MB/T_OUT_ZONE[0-2]

SNMP Trap: sunHwTrapTempCritThresholdDeasserted

Oracle ILOM Event Message: Upper critical threshold no longer exceeded

Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/T_OUT

/SYS/PS[0-1]/T_IN

/SYS/MB/T_IN_ZONE[0-2]

/SYS/MB/T_OUT_ZONE[0-2]

SNMP Trap: sunHwTrapTempFatalThresholdExceeded

Oracle ILOM Event Message: Lower fatal threshold exceeded

Severity and Description: Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/T_AMB

SNMP Trap: sunHwTrapTempFatalThresholdDeasserted

Oracle ILOM Event Message: Lower fatal threshold no longer exceeded

Severity and Description: Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/T_AMB

Hard Disk Drive Events

The following table lists hard disk drive events.

Messages and Descriptions Component Name

SNMP Trap: sunHwTrapSlotOrConnectorError

Oracle ILOM Event Message: Assert

Severity and Description: Major: A sensor associated with a slot or connector has detected an error.

/SYS/DBP/HDD[0-x]/STATE

SNMP Trap: sunHwTrapSlotOrConnectorOk

Oracle ILOM Event Message: Deassert

Severity and Description: Informational; A sensor associated with a slot or connector has returned to its normal state.

/SYS/DBP/HDD[0-x]/STATE

Power Events

The following table lists power events.

Messages and Descriptions Component Name

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_PRESENCE ASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_PRESENCE DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_FAILURE ASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_FAILURE DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_PREDICTIVE_FAILURE ASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_PREDICTIVE_FAILURE DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_INPUT_LOST ASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_INPUT_LOST DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_INPUT_ERROR ASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_INPUT_ERROR DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_INPUT_RANGE_ERROR ASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_INPUT_RANGE_ERROR DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyError

Oracle ILOM Event Message: PS_CONFIG_ERROR ASSERT

Severity and Description Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapPowerSupplyOk

Oracle ILOM Event Message: PS_CONFIG_ERROR DEASSERT

Severity and Description: Major; A power supply sensor has detected an error.

/SYS/PS[0-1]/STATE

SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded

Oracle ILOM Event Message: Upper noncritical threshold exceeded

Severity and Description: Minor; A sensor has reported that its value has gone above an upper non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/VPS

SNMP Trap: sunHwTrapSensorThresholdOk

Oracle ILOM Event Message:Upper noncritical threshold no longer exceeded

Severity and Description: Informational; A sensor has reported that its value is in the normal operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type.

/SYS/VPS

SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded

Oracle ILOM Event Message: Upper noncritical threshold exceeded

Severity and Description: Minor; A sensor has reported that its value has gone above an upper noncritical threshold setting or below a lower noncritical threshold setting. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/VPS_FANS

/SYS/PS[0-1]/P_IN

/SYS/PS[0-1]/P_OUT

SNMP Trap: sunHwTrapSensorThresholdOk

Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded

Severity and Description: Informational; A sensor has reported that its value is in the normal operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type.

/SYS/VPS_FANS

/SYS/PS[0-1]/P_IN

/SYS/PS[0-1]/P_OUT

SNMP Trap: sunHwTrapSensorFatalThresholdExceeded

Oracle ILOM Event Message: Lower fatal threshold exceeded

Severity and Description: Critical; A power supply sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/P_IN

/SYS/PS[0-1]/P_OUT

SNMP Trap: sunHwTrapSensorFatalThresholdDeasserted

Oracle ILOM Event Message: Lower fatal threshold no longer exceeded

Severity and Description: Informational; A power supply sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/P_IN

/SYS/PS[0-1]/P_OUT

SNMP Trap: sunHwTrapSensorCritThresholdExceeded

Oracle ILOM Event Message: Lower critical threshold exceeded

Severity and Description: Major; A power supply sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/P_IN

/SYS/PS[0-1]/P_OUT

SNMP Trap: sunHwTrapSensorCritThresholdDeasserted

Oracle ILOM Event Message: Lower critical threshold no longer exceeded

Severity and Description: Informational; A power supply sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/P_IN

/SYS/PS[0-1]/P_OUT

SNMP Trap: sunHwTrapVoltageFatalThresholdExceeded

Oracle ILOM Event Message: Lower fatal threshold exceeded

Severity and Description: Critical; A voltage sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/V_12V

/SYS/PS[0-1]/V_12V_STBY

/SYS/PS[0-1]/V_IN

SNMP Trap: sunHwTrapVoltageFatalThresholdDeasserted

Oracle ILOM Event Message: Lower fatal threshold no longer exceeded

Severity and Description: Informational; A voltage sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/V_12V

/SYS/PS[0-1]/V_12V_STBY

/SYS/PS[0-1]/V_IN

SNMP Trap: sunHwTrapVoltageCritThresholdExceeded

Oracle ILOM Event Message: Upper critical threshold exceeded

Severity and Description: Critical; A voltage sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/V_12V

/SYS/PS[0-1]/V_12V_STBY

/SYS/PS[0-1]/V_IN

SNMP Trap: sunHwTrapVoltageCritThresholdDeasserted

Oracle ILOM Event Message: Upper critical threshold no longer exceeded

Severity and Description: Informational; A voltage sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/V_12V

/SYS/PS[0-1]/V_12V_STBY

/SYS/PS[0-1]/V_IN

SNMP Trap: sunHwTrapVoltageNonCritThresholdExceeded

Oracle ILOM Event Message: Upper noncritical threshold exceeded

Severity and Description: Minor; A voltage sensor has reported that its value has gone above an upper noncritical threshold setting or below a lower noncritical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/PS[0-1]/V_12V

/SYS/PS[0-1]/V_12V_STBY

/SYS/PS[0-1]/V_IN

SNMP Trap: sunHwTrapVoltageOk

Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded

Severity and Description: Informational; A voltage sensor has reported that its value is in the normal operating range.

/SYS/PS[0-1]/V_12V

/SYS/PS[0-1]/V_12V_STBY

/SYS/PS[0-1]/V_IN

SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded

Oracle ILOM Event Message: Upper noncritical threshold exceeded

Severity and Description: Minor; A sensor has reported that its value has gone above an upper noncritical threshold setting or below a lower noncritical threshold setting. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/VPS_CPUS

/SYS/VPS_MEMORY

SNMP Trap: sunHwTrapSensorThresholdOk

Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded

Severity and Description: Informational; A sensor has reported that its value is in the normal operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize the component type.

/SYS/VPS_CPUS

/SYS/VPS_MEMORY

Fan Events

The following table lists fan events.

Messages and Descriptions Component Name

SNMP Trap: sunHwTrapFanSpeedCritThresholdExceeded

Oracle ILOM Event Message: Lower critical threshold exceeded

Severity and Description: Major; A fan speed sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/MB/FM[0-3]/F[0-x]/TACH

SNMP Trap: sunHwTrapFanSpeedCritThresholdDeasserted

Oracle ILOM Event Message: Lower critical threshold no longer exceeded

Severity and Description: Informational; A fan speed sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/MB/FM[0-3]/F[0-x]/TACH

SNMP Trap: sunHwTrapFanSpeedFatalThresholdExceeded

Oracle ILOM Event Message: Lower fatal threshold exceeded

Severity and Description: Critical; A fan speed sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/MB/FM[0-3]/F[0-x]/TACH

SNMP Trap: sunHwTrapFanSpeedFatalThresholdDeasserted

Oracle ILOM Event Message: Lower fatal threshold no longer exceeded

Severity and Description: Informational; A fan speed sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting.

The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.

/SYS/MB/FM[0-3]/F[0-x]/TACH

Memory Events

The following table lists memory events.

Messages and Descriptions Component Name

SNMP Trap: sunHwTrapMemoryFault

Oracle ILOM Event Message: event fault.cpu.intel.quickpath.link_slow "The Quickpath Interconnect (QPI) link is operating below normal speed."

Severity and Description: Major; A memory component is suspected of causing a fault.

/SYS/MB

SNMP Trap: sunHwTrapMemoryFaultCleared

Oracle ILOM Event Message: event fault.cpu.intel.quickpath.link_slow "The Quickpath Interconnect (QPI) link is operating below normal speed."

Severity and Description: Informational; A memory component fault has been cleared.

/SYS/MB

SNMP Trap: sunHwTrapMemoryFault

Oracle ILOM Event Message: event fault.cpu.intel.quickpath.unknown-errcode "An unknown error code from the Quickpath Interconnect (QPI) reference code has been detected."

Severity and Description: Major; A memory component is suspected of causing a fault.

/SYS/MB

SNMP Trap: sunHwTrapMemoryFaultCleared

Oracle ILOM Event Message: event fault.cpu.intel.quickpath.unknown-errcode "An unknown error code from the Quickpath Interconnect (QPI) reference code has been detected."

Severity and Description: Informational; A memory component fault has been cleared.

/SYS/MB

Entity Presence Events

The following table lists entity presence events.

Messages and Descriptions Component Name

SNMP Trap: sunHwTrapProcessorError

Oracle ILOM Event Message: ENTITY_PRESENT ASSERT

Severity and Description: Major; A processor sensor has detected an error. Device absent.

/SYS/MB/P[0-x]/PRSNT

SNMP Trap: sunHwTrapProcessorOk

Oracle ILOM Event Message: ENTITY_PRESENT DEASSERT

Severity and Description: Major; A processor sensor has returned to its normal state. Device present.

/SYS/MB/P[0-x]/PRSNT

SNMP Trap: sunHwTrapProcessorError

Oracle ILOM Event Message: ENTITY_DISABLED ASSERT

Severity and Description: Major; A processor sensor has detected an error. Device disabled.

/SYS/MB/P[0-x]/PRSNT

SNMP Trap: sunHwTrapProcessorOk

Oracle ILOM Event Message: ENTITY_DISABLED DEASSERT

Severity and Description: Major; A processor sensor has returned to its normal state. Device enabled.

/SYS/MB/P[0-x]/PRSNT