Overview of the Oracle ZFS Storage ZS3-4 Controller
This section provides an overview of the Oracle ZFS Storage ZS3-4 controller. For installation instructions, refer to Installing an Oracle ZFS Storage ZS4-4 or Oracle ZFS Storage ZS3-4 Controller. For service instructions, refer to Servicing the Oracle ZFS Storage ZS3-4 Controller in Oracle ZFS Storage Appliance Customer Service Manual, Release OS8.8.x.
Oracle ZFS Storage ZS3-4 Electrical Specifications
The following list shows the electrical specifications for the Oracle ZFS Storage ZS3-4 controller.
Note:
The power dissipation numbers listed are the maximum rated power numbers for the power supply. The numbers are not a rating of the actual power consumption of the appliance.Input
-
Nominal frequencies: 50/60Hz
-
AC operating range: 200-240 VAC
-
Maximum current AC RMS: 12A @ 200 VAC
Power Dissipation
-
Max power consumption: 1800 W
-
Max heat output: 6143 BTU/hr
-
Volt-Ampere rating: 1837 VA @ 240 VAC, 0.98 P.F.
Oracle ZFS Storage ZS3-4 Configuration Options
The Oracle ZFS Storage ZS3-4 controller can be configured as a single controller or two controllers to create a high-availability cluster configuration. The following table describes the configuration options:
CPU | Memory | Readzilla SAS-2 | Boot Drive SAS-2 | HBA SAS-2 |
---|---|---|---|---|
4x10-core, 2.40GHz |
1TB (16GB DIMMs) |
Four SSDs |
Two HDDs |
4-port (4X4) SAS-2 6Gb/s external |
Refer to https://oracle.com/zfsstorage for the most recent component specification.
Oracle ZFS Storage ZS3-4 Front Panel Components
![Graphic showing the LEDs and components at the front of the Oracle ZFS Storage ZS3-4 controller Graphic showing the LEDs and components at the front of the Oracle ZFS Storage ZS3-4 controller](img/a1945-zs3-x_front_panel.jpg)
1 Locator LED and button (white) |
2 Service Required LED (amber) |
3 Power/OK LED (green) |
4 Power button |
5 Service Processor (SP) OK LED (green) |
6 Fan/CPU/Memory Service Required LED |
7 Power Supply (PS) Service Required LED |
8 Over Temperature Warning LED |
9 USB 2.0 Connectors |
10 DB-15 video connector |
11 Boot drive 0 (required) |
12 Boot drive 1 (required) |
13 Solid state drive 2 (optional) |
14 Solid state drive 3 (optional) |
15 Solid state drive 4 (optional) |
16 Solid state drive 5 (optional) |
The Oracle ZFS Storage ZS3-4 controller has two SAS-2 system boot drives in slots 0 and 1, configured as a mirrored pair. Up to four SAS-2 read cache SSDs can fill slots 2 through 5, in order.
![Graphic showing the three LEDs at the front of the boot drive Graphic showing the three LEDs at the front of the boot drive](img/driveledszs3-4.png)
1 Ready to remove (blue) |
2 Service action required (amber) |
3 OK/Activity (green) |
Oracle ZFS Storage ZS3-4 Rear Panel Components
The following graphic shows the rear panel of the Oracle ZFS Storage ZS3-4 controller. Base configuration HBAs are not depicted in this illustration.
For information about PCIe cards, see Oracle ZFS Storage ZS3-4 PCIe I/O Cards in Oracle ZFS Storage Appliance Customer Service Manual, Release OS8.8.x.
![Graphic showing the components at the back of the controller Graphic showing the components at the back of the controller](img/rearpanel7420.png)
1 Power supply unit 0 status LEDs OK: green Power Supply Fail: amber AC OK: green |
2 Power supply unit 0 AC inlet |
3 Power supply unit 1 status LEDs OK: green Power Supply Fail: amber AC OK: green |
4 Power supply unit 1 AC inlet |
5 System status LEDs Power: green Attention: amber Locate: white |
6 PCIe slots 0-4 |
7 Cluster card slot |
8 Network (NET) 10/100/1000 ports: NET 0-NET 3 |
9 USB 2.0 ports |
10 PCIe slots 5-9 |
11 Network management (NET MGT) 10/100 BASE-T Ethernet port |
12 Serial management (SER MGT) port |
13 DB-15 video connector |
-
Ethernet Ports - Oracle ZFS Storage ZS3-4 has four RJ-45 Gigabit Ethernet connectors (NET 0, NET 1, NET 2, NET 3) located on the motherboard that operate at 10/100/1000 Mbit/sec. These network interfaces must be configured before use.
-
Network Management Port - The network management connector (NET MGT) is an RJ-45 10/100 BASE-T Ethernet port and provides a LAN interface to the SP console.
-
Serial Management Port - The serial management connector (SER MGT) is an RJ-45 connector and provides a terminal connection to the SP console.
-
HBA Ports - The 4x4 SAS-2 HBA, installed in Oracle ZFS Storage ZS3-4, provides connectivity to external Oracle Storage Drive Enclosure DE2 and Sun Disk Shelves. The HBA logical ports are numbered 3-0, top to bottom: