Checking the Status of Storage Firmware Updates (CLI)
Checking the Status of Storage Firmware Updates (CLI)
Go to maintenance system updates, and enter firmware.
hostname:maintenance system updates> firmware
Enter get to see the number of pending, failed, and in-progress firmware updates.
hostname:maintenance system updates firmware> get
upgrades_pending = 1
upgrades_failed = 1
upgrades_in_progress = 0
Enter show to view firmware update details.
hostname:maintenance system updates firmware> show
Properties:
upgrades_pending = 1
upgrades_failed = 1
upgrades_in_progress = 0
Status:
Pending
Component Current Version Status
Chassis 0945QCQ01A (SAS Expander 00) 3232 some disks only have 1
path(s) (2 paths required)
Failed
Component Current Version Status
Chassis 0945QCQ00A (SAS Expander 00) 3232 some disks only have 1
path(s) (2 paths required)
In Progress
No Updates in Progress
For clustered controllers, the status only shows the updates that are pending on the primary controller. Therefore, firmware updates displayed on the peer controller do not include firmware updates for the primary controller.